Vivotek HLG-120H Manual


Læs nedenfor 📖 manual på dansk for Vivotek HLG-120H (6 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 44 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/6
IP65 IP67
SPECIFICATION
MODEL
HLG-120H-24
HLG-120H-48
HLG-120H-54
OUTPUT
DC VOLTAGE
24V
48V
54V
CONSTANT CURRENT REGION
Note.4
12 ~ 24V
24 ~ 48V
27 ~ 54V
RATED CURRENT
5A
2.5A
2.3A
RATED POWER
120W
120W
124.2W
RIPPLE & NOISE (max.) Note.2
150mVp-p
200mVp-p
200mVp-p
VOLTAGE ADJ. RANGE Note.6
22 ~ 27V
43 ~ 53V
49 ~ 58V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer A type only
2.5 ~ 5A
1.2 ~ 2.5A
1.1 ~ 2.3A
VOLTAGE TOLERANCE Note.3
±1.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME Note.8
1200ms,50ms/115VAC 500ms,50ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
HOLD UP TIME (Typ.)
12ms at full load 230VAC / 115VAC
INPUT
VOLTAGE RANGE Note.5
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 50% at 115VAC/230VAC input and output loading 75% at 277VAC input
EFFICIENCY (Typ.)
93%
93.5%
93.5%
AC CURRENT (Typ.)
1.4A / 115VAC 0.6A / 230VAC 0.55A / 277VAC
INRUSH CURRENT (Typ.)
COLD START 60A(t =375width μs measured at % I ) at V50 peak 230 AC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
PROTECTION
OVER CURRENT
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
28 ~ 34V
54 ~ 63V
59 ~ 65V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH -condensingnon
STORAGE TEMP., HUMIDITY
-40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
SAFETY STANDARDS Note.7
UL8750, CSA C22.2 No. 250.0-08, ENEC, TUV EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1,
J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERS
MTBF
192.2K hrs min. MIL-HDBK-217F (25 )
DIMENSION
220*68*38.8mm (L*W*H)
PACKING
1.12Kg; 12pcs/14.4Kg/0.8CUFT
NOTE
File Name:HLG-120H-SPEC 2017-11
120W Single Output Switching Power Supply
Baua rt g epru ft
Sic h erhe it
egel ma g e
od o s
be w ac g
www . tuv .co m
ID 2 000 000 000
HLG- -120H 24
HLG- -120H 48
HLG- -120H 54


Produkt Specifikationer

Mærke: Vivotek
Kategori: Ikke kategoriseret
Model: HLG-120H

Har du brug for hjælp?

Hvis du har brug for hjælp til Vivotek HLG-120H stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vivotek Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Snom

Snom HD300A Manual

4 November 2024
Atlona

Atlona NETGEAR-AXM Manual

4 November 2024
Sanus

Sanus VMF822 Manual

4 November 2024
Sanus

Sanus VLF828 Manual

4 November 2024
Sanus

Sanus VSF817 Manual

4 November 2024
BEKO

BEKO BHCP65422BCH Manual

4 November 2024
Blaupunkt

Blaupunkt GG3010 Manual

4 November 2024
Blaupunkt

Blaupunkt BP-YF07D Manual

4 November 2024
Blaupunkt

Blaupunkt GG6010 Manual

4 November 2024