Vivotek HLG-120H Manual


Læs nedenfor 📖 manual på dansk for Vivotek HLG-120H (6 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 44 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/6
IP65 IP67
SPECIFICATION
MODEL
HLG-120H-24
HLG-120H-48
HLG-120H-54
OUTPUT
DC VOLTAGE
24V
48V
54V
CONSTANT CURRENT REGION
Note.4
12 ~ 24V
24 ~ 48V
27 ~ 54V
RATED CURRENT
5A
2.5A
2.3A
RATED POWER
120W
120W
124.2W
RIPPLE & NOISE (max.) Note.2
150mVp-p
200mVp-p
200mVp-p
VOLTAGE ADJ. RANGE Note.6
22 ~ 27V
43 ~ 53V
49 ~ 58V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer A type only
2.5 ~ 5A
1.2 ~ 2.5A
1.1 ~ 2.3A
VOLTAGE TOLERANCE Note.3
±1.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME Note.8
1200ms,50ms/115VAC 500ms,50ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
HOLD UP TIME (Typ.)
12ms at full load 230VAC / 115VAC
INPUT
VOLTAGE RANGE Note.5
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 50% at 115VAC/230VAC input and output loading 75% at 277VAC input
EFFICIENCY (Typ.)
93%
93.5%
93.5%
AC CURRENT (Typ.)
1.4A / 115VAC 0.6A / 230VAC 0.55A / 277VAC
INRUSH CURRENT (Typ.)
COLD START 60A(t =375width μs measured at % I ) at V50 peak 230 AC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
PROTECTION
OVER CURRENT
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
28 ~ 34V
54 ~ 63V
59 ~ 65V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH -condensingnon
STORAGE TEMP., HUMIDITY
-40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
SAFETY STANDARDS Note.7
UL8750, CSA C22.2 No. 250.0-08, ENEC, TUV EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1,
J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERS
MTBF
192.2K hrs min. MIL-HDBK-217F (25 )
DIMENSION
220*68*38.8mm (L*W*H)
PACKING
1.12Kg; 12pcs/14.4Kg/0.8CUFT
NOTE
File Name:HLG-120H-SPEC 2017-11
120W Single Output Switching Power Supply
Baua rt g epru ft
Sic h erhe it
egel ma g e
od o s
be w ac g
www . tuv .co m
ID 2 000 000 000
HLG- -120H 24
HLG- -120H 48
HLG- -120H 54


Produkt Specifikationer

Mærke: Vivotek
Kategori: Ikke kategoriseret
Model: HLG-120H

Har du brug for hjælp?

Hvis du har brug for hjælp til Vivotek HLG-120H stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vivotek Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024