MDR- 10 series
10W Single Output Industrial DIN Rail Power Supply
File Name:MDR- -SPEC 2017-1110
SPECIFICATION
Features:
Universal AC input / Full range
Protections: Short Circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Built in DC OK active signal
LED indicator for power on
No load power consumption<0.75W
100% full load burn-in test
MODEL
MDR- -10 12
OUTPUT
DC VOLTAGE
12V
RATED CURRENT
0.84A
CURRENT RANGE
0 ~ 0.84A
RATED POWER
10W
RIPPLE & NOISE (max.) Note.2
120mVp-p
VOLTAGE TOLERANCE Note.3
±3.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±3.0%
SETUP, RISE TIME Note.5
500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
120ms/230VAC 25ms/115VAC at full load
INPUT
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
81%
AC CURRENT (Typ.)
0.33A/115VAC 0.21A/230VAC
INRUSH CURRENT (Typ.)
COLD START 35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
PROTECTION
OVERLOAD
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
13.8 ~ 16.2V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
DC OK ACTIVE SIGNAL (max.)
9 ~ 13.5V / 40mA
ENVIRONMENT
WORKING TEMP.
-20 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50 )
VIBRATION
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS
UL508, TUV EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3- -32,
EMC IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A
OTHERS
MTBF
584K hrs min. MIL-HDBK-217F (25 )
DIMENSION
22.5*90*100mm (W*H*D)
PACKING
0.17Kg; 72pcs/13.2Kg/0.91CUFT
NOTE
1. All parameters NOT Specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. “ ”
5. Length of set up time is measured at cold first start. Turning ON/OFF power supply may lead to increase to the set up time.


Produkt Specifikationer

Mærke: Vivotek
Kategori: Ikke kategoriseret
Model: MDR-10

Har du brug for hjælp?

Hvis du har brug for hjælp til Vivotek MDR-10 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vivotek Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Kramer

Kramer VP-8X8 Manual

25 November 2024
Kramer

Kramer PT-2C Manual

25 November 2024
Lazer

Lazer Bob+ Manual

25 November 2024
Dometic

Dometic DPS 80 Manual

25 November 2024
Kramer

Kramer 102MX Manual

25 November 2024
Kramer

Kramer FC-18 Manual

25 November 2024
Kramer

Kramer DSP-62-UC Manual

25 November 2024
Tiger

Tiger SKF-H101 Manual

25 November 2024