Zephyr Monsoon Mini II AK9540AS Manual
Læs nedenfor 📖 manual på dansk for Zephyr Monsoon Mini II AK9540AS (56 sider) i kategorien Emhætte. Denne guide var nyttig for 7 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/56
WWW.ZEPHYRONLINE.COM
MAY21.0101
Airflow Control Technology
TM
C
Monsoon Mini II
AK9528AS, AK9534AS, AK9540AS, AK9546AS
EN Use, Care, and Installation Guide
FR Guide d’utilisation, d’entretien et d’installation
2Monsoon Mini II Use, Care, and Installation Guide
3
Monsoon Mini II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Contents
Page
Safety Information ............................................................................ 4-6
Types of Safety Warnings ................................................................... 4
General Safety ..................................................................................4-5
Operation ........................................................................................... 6
Electrical Requirements ...................................................................... 6
List of Materials ................................................................................... 7
Installation Instructions .....................................................................8-17
Ducting Calculation Sheet .................................................................. 8
Mounting Height, Clearance, & Ducting ........................................... 9-10
Ducting Options ................................................................................. 11
Hood Specifications ............................................................................12
Electrical Supply .................................................................................13
Cable Lock .........................................................................................13
Mounting the Hood .......................................................................... 14-15
Ducting Preparation ...........................................................................16
Ductless Recirculation ........................................................................17
Recirculating Kit Installation ...............................................................17
Features & Controls ............................................................................ 18
Electronic Touch Controls ...................................................................18
Maintenance ....................................................................................19-20
Hood & Filter Cleaning .....................................................................19-20
LumiLight LED ................................................................................... 20
ACT™ Conversion .............................................................................21-22
Airflow Control Technology (ACT™) ....................................................21
Enabling ACT™ .................................................................................. 22
Wiring Diagram .................................................................................. 23
Troubleshooting............................................................................... 24-25
List of Parts & Accessories .................................................................. 26
Limited Warranty ...............................................................................27
Product Registration ........................................................................... 28
4Monsoon Mini II Use, Care, and Installation Guide
M O N S O O N M I N I I I
I N S E RT
C O R E
Safety Information
Your safety and the safety of others are very important.
We have provided many important safety messages in this
manual for your appliance. Always read and obey all safety
messages.
This is the Safety Alert Symbol. This symbol alerts you to
potential hazards that can cause severe bodily injury or death.
All safety messages will follow the Safety Alert Symbol and either
the words “DANGER WARNING CAUTION” “ ” or “ ”
DANGER
Danger means that failure to heed this safety statement may
result in severe injury or death.
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power o at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
General Safety
WARNING
Warning means that failure to heed this safety statement
may result in extensive product damage, serious personal
injury, or death.
CAUTION
Caution means that failure to heed this safety statement
may result in minor or moderate personal injury, property or
equipment damage.
WARNING
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
5
Monsoon Mini II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn o the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a
violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you
already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside, do
not vent exhaust air into spaces within walls, ceilings, attics,
crawl spaces, or garages.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
6Monsoon Mini II Use, Care, and Installation Guide
M O N S O O N M I N I I I
I N S E RT
C O R E
Safety Information
Operation
ŹAlways leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and
loose clothing.
ŹThe manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and
the warranty of the unit automatically expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
ŹObserve all governing codes and ordinances.
ŹIt is the customer’s responsibility to be aware of these below:
ŹTo contact a qualified electrical installer.
ŹTo assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest
edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
ŹIf codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path
is adequate.
ŹDo not ground to a gas pipe.
ŹCheck with a qualified electrician if you are not sure the range hood is properly grounded.
ŹDo not have a fuse in the neutral or ground circuit.
ŹThis appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected
by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram
on product.
ŹA cable locking connector (not supplied) might also be required by cal requirements, purchase and local codes. Check with lo
install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
READ AND SAVE THESE INSTRUCTIONS
7
Monsoon Mini II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
List of Materials
Parts Not Supplied
Ducting, conduit and all installation tools
Cable locking connector (if required by local codes)
Recirculating kit (ZRC-9100A)
Parts Supplied
Quantity Part
1 Liner hood
2 Hybrid bae filters
3 Hybrid bae filters (AK9546AS only)
2 LumiLight LED, 6W (pre-installed)
1 7” round transition collar (pre-installed)
1 3-1/4” x 10” rectangular collar
1 Rectangular top cover plate
1 Dual blower motor (pre-installed)
1 Hardware package
M4 x 6mm (6)
Wire Caps (3)
#8 x 1/2” (12)
10 Monsoon Mini II Use, Care, and Installation Guide
M O N S O O N M I N I I I
I N S E RT
C O R E
Installation Instructions
Mounting Height, Clearance, & Ducting
A minimum of 7” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air flow
eciency.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Also use the ducting calculation sheet (on page 8) to compute total available duct run when using
elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood bottom should be no less than 24”.
Maximum mount height should be no higher than 36”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result
in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its
performance and eciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood
mounting height above range. Always check your local codes for any dierences.
For shipment and installation damages:
ŹPlease fully inspect unit for damage before installation.
ŹIf the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
ŹIf the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
ŹIf the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
11
Monsoon Mini II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Ducting Options
ŹUse single wall rigid metal ductwork only.
ŹFasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
WARNING
ű
ħ
ć
ħ
ħ
ŜĚŚħŝĢŚřĢĘ
ŠĢ
ŠĢ
12 Monsoon Mini II Use, Care, and Installation Guide
M O N S O O N M I N I I I
I N S E R T
C O R E
Installation Instructions
Ů
6-15/16”
4-15/16”
(30”) 1-3/8”
(36”, 42“, 48”) 4-3/8”
1-15/16”
(30”) 27-15/16”
(36”) 33-15/16”
(42”) 39-15/16”
(48”) 45-15/16”
(30”) 28-3/8”
(36”) 34-3/8”
(42”) 40-3/8”
(48”) 46-3/8”
14-7/16”
4-
3/4”
3-1/16”
18-1/16”
6-1/8”
(30”) 1-15/16”
(36”, 42“, 48”) 4-15/16”
1-1/4”
11-1/4”
5/16”
3-3/4”
TOP
SIDE BACK
FRONT
13
Monsoon Mini II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Electrical Supply
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
FIG. A
Cable Lock
14 Monsoon Mini II Use, Care, and Installation Guide
M O N S O O N M I N I I I
I N S E RT
C O R E
Installation Instructions
Mounting the Hood
At least two installers are required due to the
weight and size of the hood.
CAUTION
1. Remove all packing materials and protective
film prior to installation. Use caution during
installation to prevent scratches or damage to
the stainless steel.
2. Cut out an opening in the bottom of the
cabinet by following the dimensions in FIG. B.
If ducting the one piece liner horizontally, also
cut out an opening in the back of the cabinet
(if applicable). FIG. C.
3. Prepare hood for installation into cabinet by
following the steps on the next page. Continue
to Step 4 after preparation is complete.
Make sure the surface you are securing the hood
to is capable of holding the weight of AK95.
Failure to do so may cause personal injury or
damage to cooking surface or counter.
WARNING
FIG. B
1
8-
1/
4
”
cu
t
out
28-
1/2
”, 34-
1/2
”, 40-
1/2
”, 46-
1/2
”
AK9528, AK9534, AK9540, AK9548
3-3/4”
11-1/4”
5/16”
C/L
CABINET BACK
FIG. C
Produkt Specifikationer
Mærke: | Zephyr |
Kategori: | Emhætte |
Model: | Monsoon Mini II AK9540AS |
Har du brug for hjælp?
Hvis du har brug for hjælp til Zephyr Monsoon Mini II AK9540AS stil et spørgsmål nedenfor, og andre brugere vil svare dig
Emhætte Zephyr Manualer
12 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
11 December 2024
Emhætte Manualer
- Emhætte DeLonghi
- Emhætte Ikea
- Emhætte Bosch
- Emhætte PKM
- Emhætte Gram
- Emhætte Wolkenstein
- Emhætte Siemens
- Emhætte Samsung
- Emhætte Scandomestic
- Emhætte GE
- Emhætte Zanussi
- Emhætte Cylinda
- Emhætte Panasonic
- Emhætte Candy
- Emhætte Fisher & Paykel
- Emhætte Gorenje
- Emhætte VOX
- Emhætte Miele
- Emhætte Silverline
- Emhætte Blomberg
- Emhætte Concept
- Emhætte Teka
- Emhætte OK
- Emhætte LG
- Emhætte AEG
- Emhætte Electrolux
- Emhætte Bauknecht
- Emhætte Elica
- Emhætte Whirlpool
- Emhætte Sharp
- Emhætte Hotpoint
- Emhætte Dacor
- Emhætte Atag
- Emhætte Omega
- Emhætte Hoover
- Emhætte Arçelik
- Emhætte Junker
- Emhætte JennAir
- Emhætte Soler & Palau
- Emhætte Grundig
- Emhætte Falmec
- Emhætte Progress
- Emhætte De Dietrich
- Emhætte Witt
- Emhætte Indesit
- Emhætte Hotpoint Ariston
- Emhætte Klarstein
- Emhætte Ardo
- Emhætte Furrion
- Emhætte Etna
- Emhætte Infiniton
- Emhætte Matsui
- Emhætte Scholtès
- Emhætte Hansa
- Emhætte Logik
- Emhætte Bartscher
- Emhætte Sauber
- Emhætte Westinghouse
- Emhætte Ilve
- Emhætte Eico
- Emhætte Thomson
- Emhætte Constructa
- Emhætte Hisense
- Emhætte Adelberg
- Emhætte Brandt
- Emhætte Airforce
- Emhætte Dometic
- Emhætte Eurom
- Emhætte Blaupunkt
- Emhætte AEG-Electrolux
- Emhætte Ariston
- Emhætte Asko
- Emhætte Becken
- Emhætte BEKO
- Emhætte Gaggenau
- Emhætte Ignis
- Emhætte Küppersbusch
- Emhætte Neff
- Emhætte Privileg
- Emhætte Sandstrøm
- Emhætte Smeg
- Emhætte Viva
- Emhætte Honeywell
- Emhætte Ariston Thermo
- Emhætte Fagor
- Emhætte Haier
- Emhætte Bomann
- Emhætte Russell Hobbs
- Emhætte KitchenAid
- Emhætte Zelmer
- Emhætte Rosieres
- Emhætte Boretti
- Emhætte Vivax
- Emhætte Mora
- Emhætte Thermex
- Emhætte Zanker
- Emhætte Amana
- Emhætte Amica
- Emhætte Arthur Martin-Electrolux
- Emhætte Euromaid
- Emhætte KKT Kolbe
- Emhætte Comfee
- Emhætte Tesy
- Emhætte Wolf
- Emhætte Dimplex
- Emhætte Kernau
- Emhætte Bertazzoni
- Emhætte Caple
- Emhætte SIBIR
- Emhætte Orbegozo
- Emhætte Viking
- Emhætte Franke
- Emhætte Faber
- Emhætte Balay
- Emhætte Cata
- Emhætte Exquisit
- Emhætte Hoover-Grepa
- Emhætte Falcon
- Emhætte Pelgrim
- Emhætte Elba
- Emhætte Elektra Bregenz
- Emhætte ELIN
- Emhætte Faure
- Emhætte Juno
- Emhætte Nodor
- Emhætte Respekta
- Emhætte Rommer
- Emhætte Stoves
- Emhætte Schneider
- Emhætte MPM
- Emhætte Profilo
- Emhætte Tesla
- Emhætte Hanseatic
- Emhætte Thor
- Emhætte V-Zug
- Emhætte Maytag
- Emhætte Aspes
- Emhætte Bellini
- Emhætte Unox
- Emhætte Scancool
- Emhætte Roblin
- Emhætte Imperial
- Emhætte Inventum
- Emhætte Weller
- Emhætte Midea
- Emhætte Napoleon
- Emhætte CDA
- Emhætte Frigidaire
- Emhætte Frilec
- Emhætte Esatto
- Emhætte SVAN
- Emhætte Lofra
- Emhætte ECG
- Emhætte Saturn
- Emhætte Proline
- Emhætte Lynx
- Emhætte Gemini
- Emhætte Cecotec
- Emhætte Berg
- Emhætte Royal Catering
- Emhætte Technika
- Emhætte Seiki
- Emhætte Siku
- Emhætte Baumatic
- Emhætte Sirius
- Emhætte Barazza
- Emhætte Meireles
- Emhætte Gutmann
- Emhætte Kenmore
- Emhætte Vestel
- Emhætte Continental Edison
- Emhætte Cookology
- Emhætte Corbero
- Emhætte Artusi
- Emhætte La Germania
- Emhætte Orima
- Emhætte Broan
- Emhætte Lamona
- Emhætte Bestron
- Emhætte Philco
- Emhætte Mepamsa
- Emhætte Sôlt
- Emhætte Novy
- Emhætte Rex
- Emhætte Classique
- Emhætte Toolcraft
- Emhætte Kunft
- Emhætte Euro Appliances
- Emhætte Summit
- Emhætte LERAN
- Emhætte Coyote
- Emhætte Matrix
- Emhætte Fulgor Milano
- Emhætte BLANCO
- Emhætte Airlux
- Emhætte Foster
- Emhætte Sam Cook
- Emhætte Jocel
- Emhætte Elektro Helios
- Emhætte Signature
- Emhætte InAlto
- Emhætte Vitrokitchen
- Emhætte Kaiser
- Emhætte Arctic Cooling
- Emhætte Linarie
- Emhætte Glem Gas
- Emhætte Flama
- Emhætte ARC
- Emhætte Chef
- Emhætte Thermador
- Emhætte Hestan
- Emhætte Acec
- Emhætte Kluge
- Emhætte Leisure
- Emhætte AYA
- Emhætte ABK
- Emhætte Itho
- Emhætte BlueStar
- Emhætte Monogram
- Emhætte Heinner
- Emhætte Guzzanti
- Emhætte Defy
- Emhætte Nordmende
- Emhætte Rangemaster
- Emhætte Air King
- Emhætte Kelvinator
- Emhætte Steel Cucine
- Emhætte Jenn-Air
- Emhætte Limit
- Emhætte Freggia
- Emhætte Edesa
- Emhætte New World
- Emhætte Porter & Charles
- Emhætte M-System
- Emhætte German Pool
- Emhætte Belling
- Emhætte Mx Onda
- Emhætte Kleenmaid
- Emhætte Eurotech
- Emhætte Carrefour Home
- Emhætte Café
- Emhætte ZLine
- Emhætte Belion
- Emhætte Sauter
- Emhætte Tecnolux
- Emhætte Cobal
- Emhætte Premier
- Emhætte Marynen
- Emhætte Axiair
- Emhætte Mayer
- Emhætte Oranier
- Emhætte Bielmeier
- Emhætte Turbo Air
- Emhætte Schweigen
- Emhætte James
- Emhætte Apelson
- Emhætte Dominox
- Emhætte Qasair
- Emhætte Tisira
- Emhætte Everdure
- Emhætte Eudora
- Emhætte Hiberg
- Emhætte Steelmatic
- Emhætte Wells
- Emhætte Piccante
- Emhætte Best
- Emhætte Kucht
- Emhætte Helios
- Emhætte Wave
- Emhætte Halifax
- Emhætte High One
- Emhætte Whispair
- Emhætte XO
- Emhætte K&H
- Emhætte Robinhood
- Emhætte Vent-A-Hood
- Emhætte Cosmo
- Emhætte Ciarra
- Emhætte Emilia
- Emhætte Viali
- Emhætte Kobe
- Emhætte Berbel
- Emhætte Samus
- Emhætte Globalo
- Emhætte Ersa
- Emhætte Sedona
- Emhætte NuTone
- Emhætte CENDO
- Emhætte Pando
- Emhætte Applico
- Emhætte Venmar
- Emhætte Twin Eagles
- Emhætte Airone
- Emhætte Trade-Wind
- Emhætte HomeCraft
- Emhætte CEEM
- Emhætte Master Kitchen
- Emhætte St George
- Emhætte Condor
- Emhætte Baumann
Nyeste Emhætte Manualer
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025
5 Januar 2025