Accu-Chek Mobile Manual
Accu-Chek
Blodsukkermåler
Mobile
Læs nedenfor 📖 manual på dansk for Accu-Chek Mobile (146 sider) i kategorien Blodsukkermåler. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/146
User’s Manual and Quick
Start Guide
Blood glucose monitoring system
ACCU-CHEK, ACCU-CHEK MOBILE, ACCU-CHEK SMART PIX, ACCU-CHEK 360°,
ACCU-CHEK CONNECT and FASTCLIX are trademarks of Roche.
CONTINUA, the CONTINUA logos and CONTINUA CERTIFIED are trademarks,
service marks or certification marks of the Continua Health Alliance.
CONTINUA is a registered trademark in some, but not all countries in which
this product is distributed.
The USB-IF logos are trademarks of Universal Serial Bus Implementers
Forum, Inc.
© 2018 Roche Diabetes Care
M Roche Diabetes Care GmbH
Sandhofer Strasse 116
68305 Mannheim, Germany
www.accu-chek.com
08252963001(02)
1
Do Do not
2
3
4
Before testing your blood glucose: Wash your hands
with soap and warm water; rinse well to remove any
visible or invisible signs of glucose residue from, for
example, food or drink. Dry your hands thoroughly
with a clean towel.
Do perform a blood not
glucose test if the testing
site has not been washed or
is soiled or sticky (for
example, due to glucose
residue from, for example,
food or drink).
Always use a fresh, well-formed blood drop and
perform the test as quickly as possible after lancing.
Do not delay applying the
blood drop to the test area.
Do not perform a blood
glucose test with a smeared
or spread blood drop. Do not
smear the blood drop on the
test area.
When performing the test, place your finger gently on
the guidance tabs so that only the blood drop
comes into contact with the . centre of the test area
Your finger should not make any contact with the test
area. Keep your finger as still as possible.
Do attempt to force your not
finger between the guidance
tabs or apply any direct
pressure to the test area.
Avoid trembling or shaky
movements.
When the beep tone sounds and is Test in progress
displayed on the screen, remove your finger from the
test cassette immediately.
Note: You can only hear the beep tones when they
are turned on. See in the User’s Setting tones
Manual.
Do keep your finger on not
the guidance tabs or apply
pressure to the test area
after the beep tone sounds
and/or is Test in progress
displayed on the screen.
W IMPORTANT INFORMATION ON PERFORMING A BLOOD GLUCOSE TEST
An incorrectly performed blood glucose test may lead to incorrect test results which can cause the wrong therapy recommendation to be made and thus produce serious
adverse health effects. Therefore, the information on how to perform a blood glucose test correctly, carefully.read
IMMEDIATELY! DO NOT WAIT!
0
q
e
w
1
9
2
3
4
5
6
7
8
W
The meter and finger
pricker are intended for
personal use only!
They may only be used by
one and the same person
for performing a blood
glucose test. There is a risk
of infections being
transmitted if the meter or
finger pricker is used by
other people, even by family
members, or if healthcare
professionals use this meter
to test blood glucose or this
finger pricker to obtain
blood from different people.
This Quick Start Guide does
not replace the detailed
User’s Manual of your
Accu-Chek Mobile blood
glucose monitoring system.
Be sure to comply with the
safety information in the
User’s Manual and in the
package insert of the test
cassette.
1 Release button (priming
and pricking)
2 Power and enter button
3 Down/Up buttons
4 Window showing number
of available lancets
5 Lever for loading a new
lancet
6 Rotatable cap for setting
the penetration depth
7 Tip cover closed (below
right: open)
8 Test area (at the tip of the
cassette ready for a test)
9 Lancet drum
0 Slide button to release
the finger pricker
q Slide button to open the
cassette compartment
cover
w Tip cover
e Test cassette
r Guidance tabs
Why
An incorrectly performed blood
glucose test may lead to falsely
elevated blood glucose results
and thereby delivery of an
inappropriately high insulin
amount. Falsely elevated test
results are caused by the
following:
• Fingers have not been washed
or were soiled or sticky.
• If the blood drop spreads on
the finger or if the blood drop
becomes smeared on the test
area, the risk of contamination
of the test area increases
(for example, due to glucose
residue from, for example,
food or drink).
• The finger was pressed onto
the test area.
• Trembling or shaky
movements while performing
the blood glucose test.
• The blood glucose test was
not performed immediately or
the finger was resting on the
guidance tabs for too long.
Pay attention to the beep tone.
The beep tone helps you to
obtain a reliable test result.
Quick Start Guide
Start Here
r
Produkt Specifikationer
Mærke: | Accu-Chek |
Kategori: | Blodsukkermåler |
Model: | Mobile |
Har du brug for hjælp?
Hvis du har brug for hjælp til Accu-Chek Mobile stil et spørgsmål nedenfor, og andre brugere vil svare dig
Blodsukkermåler Accu-Chek Manualer
10 August 2024
8 Juli 2024
7 Juli 2024
4 Juli 2024
4 Juli 2024
4 Juli 2024
4 Juli 2024
28 Juni 2024
28 Juni 2024
28 Juni 2024
Blodsukkermåler Manualer
- Blodsukkermåler GE
- Blodsukkermåler Beurer
- Blodsukkermåler Medisana
- Blodsukkermåler Microlife
- Blodsukkermåler Abbott
- Blodsukkermåler Rossmax
- Blodsukkermåler Scala
- Blodsukkermåler OneTouch
- Blodsukkermåler IHealth
- Blodsukkermåler Bioland
- Blodsukkermåler Glucofix
- Blodsukkermåler Wellion
- Blodsukkermåler LifeScan
- Blodsukkermåler Eks
- Blodsukkermåler HMM
- Blodsukkermåler Sanofi
- Blodsukkermåler AktivMed
Nyeste Blodsukkermåler Manualer
31 August 2024
30 August 2024
26 August 2024
26 August 2024
26 August 2024
26 August 2024
24 August 2024
23 August 2024
22 August 2024