Adwa AD35 Manual

Adwa Måling AD35

Læs nedenfor 📖 manual på dansk for Adwa AD35 (2 sider) i kategorien Måling. Denne guide var nyttig for 20 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
w w w . a d w a i n s t r u m e n t s . c o m
USER MANUAL
AD33 • AD35
Waterproof EC Testers
Dear Customer,
Thank you for choosing an Adwa product.
Please read carefully this manual before start-
ing operations.
These instruments are in compliance with the
EMC Directive 89/336/EEC and Low Voltage
Directive 73/23/EEC for electrical equipments.
For additional technical information, please
e-mail us at .sales@adwainstruments.com
INTRODUCTION
AD33 and are waterproof EC testers. AD35
The housing has been completely sealed against
humidity.
All EC readings are automatically temperature
compensated, and temperature values can be
displayed in °C or °F units.
EC calibration is automatic at one point, while
temperature range is factory calibrated and can
only be adjusted by the user.
The AD33P probe supplied with the meters,
is interchangeable and can be easily replaced
by the user.
The encapsulated temperature sensor allows
fast and accurate temperature measurement
and compensation.
To prolong battery life, these models are pro-
vided with an auto-off feature that turns them
off after 5 minutes of non-use.
Moreover, when batteries become too weak to
ensure reliable readings the meter automatically
turns off.
Each meter is supplied complete with:
EC probeAD33P
4 x 1.5V batteries, button type
User manual
FRONT PANEL & DISPLAY
1. Dual line LCD
2. ON/OFF / MODE button
3. HOLD button
4. EC probe & temperature sensor
5. Probe body
6. Battery compartment (inside)
7. CAL button
8. Clip holder
1. HOLD indicator
2. Calibration mode indicator
3. Secondary LCD level with measure units
4. Primary LCD level
5. Measurement unit for primary LCD level
ISTAD35 06/17
µS
ELECTRODES & SOLUTIONS
Range
0.0 to 60.0 °C /
32.0 to 140.0 °F
0 to 1999 µS/cm (AD33)
0.0 to 199.9 µS/cm (AD35)
Resolution
0.1 °C / 0.1 °F
1 )µS/cm (AD33
0.1 )µS/cm (AD35
Accuracy
(@ 25 °C / 77 °F)
±0.5 °C / ±1.0 °F
±2 % f.s. (EC)
Calibration EC: automatic, 1 point
Temperature: adjustment
Probe AD33P (included)
Battery Type /
Life
4 x 1.5V button type
Approx. 150 hours of use
Auto-off After 5 minutes of non-use
Environment 0.0 to 50.0 °C
(32.0 to122.0 °F) RH 100 %
Dimensions /
Weight 175.5 x 39 x 23 mm/100 g
AD33P Spare EC probe for
AD33 AD35 and
AD70031P 1413 µS/cm EC standard
solution sachet, 25 x 20 ml
AD7031 1413 µS/cm EC standard
solution, 230 mL bottle
AD7033 84 µS/cm EC standard
solution, 230 mL bottle
TECHNICAL DATA


Produkt Specifikationer

Mærke: Adwa
Kategori: Måling
Model: AD35

Har du brug for hjælp?

Hvis du har brug for hjælp til Adwa AD35 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Adwa Manualer

Adwa

Adwa AD1020 Manual

1 Juni 2024
Adwa

Adwa AD1200 Manual

1 Juni 2024
Adwa

Adwa AD630 Manual

1 Juni 2024
Adwa

Adwa AD35 Manual

1 Juni 2024
Adwa

Adwa AD132 Manual

1 Juni 2024
Adwa

Adwa AD12 Manual

1 Juni 2024
Adwa

Adwa AD202 Manual

1 Juni 2024
Adwa

Adwa AD410 Manual

1 Juni 2024

Måling Manualer

Nyeste Måling Manualer

Steinberg

Steinberg SBS-DL-123 Manual

16 December 2024
Steinberg

Steinberg SBS-DL-125E Manual

16 December 2024
Helvi

Helvi T1 Manual

15 December 2024
Steinberg

Steinberg SBS-DL-123L Manual

15 December 2024
Testo

Testo 160 THL Manual

15 December 2024
DriveTest

DriveTest BIA-1 BT Manual

14 December 2024
PQ Plus

PQ Plus UMD 705 Manual

14 December 2024
Testo

Testo 318 Manual

14 December 2024
Crowcon

Crowcon Gasman-O2 Manual

13 December 2024