Andrews Polar Breeze Manual

Andrews Airconditioner Polar Breeze

Læs nedenfor 📖 manual på dansk for Andrews Polar Breeze (2 sider) i kategorien Airconditioner. Denne guide var nyttig for 15 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Click www.andrews-sykes.com
or Call Us Free 0800 211 611
Polar Breeze
Portable Air Conditioning
Operating Instructions
& Safety Guide
Getting started and operation
Never operate the unit in very hot or cold conditions - it works properly
at temperatures between 17 and 30º C.
Always allow the unit to stand/settle for 15 minutes before switching on
when either setting up or restarting.
Put the mobile air conditioner in a flat location where the air outlets
cannot be covered up. Place the unit no less than 50cm away from a
wall or other obstacle
Fit the square end of the exhaust duct to the exhaust terminal of
the unit (fig. 1).
Put the other end (discharge) to the nearest window. The length
of the air exhaust between 600 - 1800mm. Use the min length
when working. When mounting, try to keep the air exhaust
horizontal, sloping up or down. Never operate if the hose is kinked
or sagging (fig. 2 & 3).
If mounting through the wall, the height of the hole should be
40 - 130cm.
General Safety
Keep children and animals away from air conditioning units.
Never leave them alone in a room where the units in use.
This equipment should only be used by a competent person who
has read and understood these instructions.
Never operate this equipment if you are ill, feeling tired or under the
influence of alcohol or drugs.
Keep the Air Conditioning vents clear of all obstructions.
Never put anything on top of the unit or block the air outlets.
Make sure equipment is switched off and unplugged after use.
Never leave switched on or unattended.
Do not use the unit where sunlight is shining directly onto it.
Check condition of equipment before use. If unit is showing signs
of damage contact your supplier immediately.
Electrical safety
This unit requires a 230 volt electrical supply. It plugs into a
standard domestic socket.
Always inspect plugs and leads for damage before plugging into
power supply. DO NOT USE IF ANY DAMAGE IS FOUND.
Ensure cables are installed so as not to cause a hazard.
If an extension lead is used, ensure it to the correct standard and
fully unwound before use.
Do not lay electrical cables in wet/damp areas.
Do not move equipment whilst operating.
Do not pull equipment by the power lead.
It is recommended that an RCD is used whilst operating this unit. Fig. 1
Fig. 2
Fig. 3


Produkt Specifikationer

Mærke: Andrews
Kategori: Airconditioner
Model: Polar Breeze

Har du brug for hjælp?

Hvis du har brug for hjælp til Andrews Polar Breeze stil et spørgsmål nedenfor, og andre brugere vil svare dig




Airconditioner Andrews Manualer

Airconditioner Manualer

Nyeste Airconditioner Manualer

Klarbach

Klarbach CM30751 Manual

22 September 2024
MPM

MPM MKL-01 Manual

19 September 2024
Telair

Telair SILENT 5400H Manual

18 September 2024
Heiko

Heiko JS025-C1 Manual

17 September 2024
Klima1stKlaas

Klima1stKlaas 5099 Manual

16 September 2024
Fujitsu

Fujitsu ASYG 07LE Manual

22 August 2024
Fujitsu

Fujitsu AOT90TP Manual

22 August 2024
Fakir

Fakir Airwell Manual

21 August 2024