Specifications
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected. Remove the “Stop!
Connect the Battery” label that covers the outlets. Prior to connecting any equipment
to the unit, connect the battery cable to the unused battery terminal. It is normal for
small sparks to be seen when the battery cable is connected to the battery terminal.
Wall Mount Installation
• Horizontal installation, use 2 screws 5.0" (127 mm) apart.
• Vertical installation, use 2 screws 4.3" (110.4 mm) apart.
• Allow 5/16" (8 mm), of the screw to protrude from the wall.
Connect Equipment
Battery Backup + Surge Protection Outlets
Battery backup outlets provide protection to connected equipment when the
Back-UPS is turned on and connected to utility power.
Battery backup outlets receive power from the Back-UPS for a limited period of time
when a power outage, or brownout condition occurs.
Battery backup outlets provide protection from power surges or spikes.
Connect a computer, monitor and other peripheral devices to the outlets.
Surge Protection Outlets
Surge protection outlets provide protection to connected equipment when the
Back-UPS is connected to utility power, and is switched on or off.
Surge protection outlets provide protection from power surges or spikes.
Connect a printer, scanner or other peripheral devices that do not need to remain on
during power outages, or utility problems to the surge protection outlets.
Connect telephone line
The Back-UPS protects equipment connected to a telephone line from power surges
when connected through the Back-UPS coaxial connectors.
Turn On the Back-UPS
Press the POWER ON button located on the top of the Back-UPS. The Power On/
Replace Battery LED will illuminate and a single short beep will be audible to
indicate that the Back-UPS is providing protection for connected equipment.
The Back-UPS battery charges fully during the first 16 hours while connected to
utility power. The Back-UPS battery will charge while the Back-UPS is switched on
or off and is connected to utility power. Do not expect full battery run capability
during the initial charge time.
If the red Building Wiring Fault LED located on the side of the Back-UPS
illuminates, do not operate the Back-UPS. Have a qualified electrician correct the
building wiring fault.
Voltage Sensitivity Adjustment (optional)
The Back-UPS detects and reacts to line voltage distortions by transferring to battery
backup power to protect connected equipment. In situations where either the
Back-UPS or the connected equipment is too sensitive for the input voltage level it is
necessary to adjust the transfer voltage.
1. Connect the Back-UPS to a wall outlet. The Back-UPS will be in Standby mode,
no indicators will be illuminated.
2. Press and hold the ON/OFF button for 10 seconds. The OnLine LED will
illuminate alternately green-amber-red, to indicate that the Back-UPS is in
Program mode.
3. The Power On/Replace Battery LED will flash either green, amber, or red to
indicate the current sensitivity level. Refer to the table for an explanation of the
transfer voltage sensitivity levels.
4. To select LOW sensitivity, press and hold the ON/OFF button until the LED
flashes green.
5. To select MEDIUM sensitivity, press and hold the ON/OFF button until the LED
flashes red.
6. To select HIGH sensitivity, press and hold the ON/OFF button until the LED
flashes amber.
7. To exit Program mode wait five seconds and all LED indicators will extinguish.
Program mode is no longer active.
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in
contact with fluids, or where there is
excessive dust or humidity.
Connect the Back-UPS power cord directly to
a wall outlet. Do not use a surge protector or
an extension cord.
Input
Voltage 120 Vac Nominal
Frequency 60 Hz + 3
Brownout Transfers 92 Vac Typical
Over-voltage Transfer 139 Vac Typical
Output
UPS Capacity (3 outlets) 350 VA, 200 W
Total Amperage (6
outlets)
8 A (including UPS output)
Voltage - On Battery 115 Vac ± 8%
Frequency - On Battery 60 Hz + 1
Transfer Time 6 ms Typical, 10 ms maximum
Protection
and
Filtering
AC Surge Protection Full time, 340 Joules
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery
Type Sealed, maintenance-free, lead
acid Replacement battery cartridge
RBC35
Average Life 3 - 5 years depending on the
number of discharge cycles and
environmental temperature
Physical
Net Weight 9 lb (4 kg)
Dimensions
Length x Width x Height
11 in x 6 in x 3 in
29 cm x 16 cm x 9 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature 5º F to 113º F (–15º C to 45º C)
Operating Relative
Humidity 0 to 95% non-condensing
humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
EMC
Compliance
This device complies with part 68 and part 15 of the FCC
rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation.
Press the battery compartment cover
release tab located on the rear side of the
unit. Slide the battery cover off.
Connect the battery cable securely to
the battery terminal.
Reinstall the battery compartment
cover. Be sure that the release tab locks
into place.
bu064a
bu065a
bu066a
LED
Flashes Sensitivity
Setting Input Voltage Range
(Utility Operation) Recommended Use
Green LOW 88 Vac to 142 Vac Use this setting with equipment that
is less sensitive to fluctuations in
voltage or waveform distortions.
Red MEDIUM 92 Vac to 139 Vac Factory default setting. Use this
setting under normal conditions.
Amber HIGH 96 Vac to 136 Vac Use this setting when connected
equipment is sensitive to voltage
and waveform fluctuations.
bu206a
Back-UPS
Battery Backup +
Surge Protection
Surge Protection
bu230a
CAUTION-Refer to bottom
of unit for safety markings.
Circuit
Breaker
Building
Wiring Fault
Te l
Out
Push to
Reset
Te l
In
User Manual Back-UPS® BE350G Series
Produkt Specifikationer
Mærke: | APC |
Kategori: | Uafbrydelig strømforsyning (UPS) |
Model: | Back-UPS ES 350 |
Bredde: | 159 mm |
Dybde: | 279 mm |
Højde: | 89 mm |
Vægt: | 3640 g |
Produktfarve: | Sort |
Pakkevægt: | 3910 g |
Batteriteknologi: | Blybatterier (VRLA) |
Formfaktor: | Kompakt |
Opbevaringstemperatur (T-T): | -15 - 45 °C |
Relativ luftfugtighed ved drift (H-H): | 5 - 95 % |
Relativ luftfugtighed ved opbevaring (H-H): | 5 - 95 % |
Driftstemperatur (T-T): | 0 - 40 °C |
Støjniveau: | 45 dB |
Udgangseffekt: | 200 W |
Certificering: | cUL, FCC, NOM |
Filtrering: | Ja |
LED-indikatorer: | Erstatningsbatteri |
Kabellængde: | 1.52 m |
Batteritype: | RBC35 |
Opladningstid for batteri: | 16 t |
Bæredygtighedscertifikater: | RoHS |
Driftshøjde: | 0 - 3000 m |
Ikke-drift højde: | 0 - 15000 m |
Indgangsfrekvens: | 50/60 Hz |
Lydalarmer: | Ja |
Nominel udgangsspænding: | 120 V |
Nominel indgangsspænding: | 120 V |
Modem-porte (RJ-11): | 2 |
AC udgange, antal: | 6 AC stikkontakt(er) |
AC stikkontakt typer: | NEMA 5–15R |
Overspænding energivurdering: | 365 J |
Indgående driftsspænding (maks.): | - V |
Output strømkapacitet (VA): | 0.35 kVA |
Indgående driftsspænding (min.): | - V |
Udgangs driftsspænding (min.): | - V |
Udgangs driftsspænding (maks.): | - V |
Beskyttelsesfunktioner mod strømstød: | Fax, Modem, Telephone |
Beskyttelse ved overspænding: | Ja |
Hørbare alarmtilstande: | Erstatningsbatteri |
Har du brug for hjælp?
Hvis du har brug for hjælp til APC Back-UPS ES 350 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Uafbrydelig strømforsyning (UPS) APC Manualer
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
24 September 2024
24 September 2024
24 September 2024
17 September 2024
17 September 2024
5 Maj 2024
Uafbrydelig strømforsyning (UPS) Manualer
- Uafbrydelig strømforsyning (UPS) Ikea
- Uafbrydelig strømforsyning (UPS) Siemens
- Uafbrydelig strømforsyning (UPS) CyberPower
- Uafbrydelig strømforsyning (UPS) HP
- Uafbrydelig strømforsyning (UPS) GYS
- Uafbrydelig strømforsyning (UPS) Lenovo
- Uafbrydelig strømforsyning (UPS) Adj
- Uafbrydelig strømforsyning (UPS) Wago
- Uafbrydelig strømforsyning (UPS) Gembird
- Uafbrydelig strømforsyning (UPS) Tripp Lite
- Uafbrydelig strømforsyning (UPS) Digitus
- Uafbrydelig strømforsyning (UPS) Aiptek
- Uafbrydelig strømforsyning (UPS) EnerGenie
- Uafbrydelig strømforsyning (UPS) Voltcraft
- Uafbrydelig strømforsyning (UPS) LevelOne
- Uafbrydelig strømforsyning (UPS) Eaton
- Uafbrydelig strømforsyning (UPS) BlueWalker
- Uafbrydelig strømforsyning (UPS) V7
- Uafbrydelig strømforsyning (UPS) Steren
- Uafbrydelig strømforsyning (UPS) Salicru
- Uafbrydelig strømforsyning (UPS) Approx
Nyeste Uafbrydelig strømforsyning (UPS) Manualer
15 November 2024
8 November 2024
8 November 2024
22 Oktober 2024
22 Oktober 2024
21 Oktober 2024
2 Oktober 2024
24 September 2024
23 September 2024
23 September 2024