APC Back-UPS XS 1500 Manual


Læs nedenfor 📖 manual på dansk for APC Back-UPS XS 1500 (2 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne guide var nyttig for 3 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
CONNECT TVSS
User Manual
Back-UPS XS 1500
12 4
CONNECT BATTERY CARTRIDGE OPERATING ENVIRONMENT
7CONNECT EQUIPMENT / POWER
Monitor
Printer or Scanner FAX
External Disk or
CD / DVD Drive
Input: 120V~
12A, 60Hz
Circuit Breaker
Push to Reset
SURGE
ONLY
BATTERY BACKUP
Computer
8CHECK BUILDING WIRING
FAULT INDICATOR
Building
Wiring Fault
Wall
Outlet
Modem/
Phone/Fax
TVSS GND
Building Wiring
Fault Indicator
6
Phone Jack
Computer
Modem Port
CONNECT PHONE/
TVSS GND
Wall
Outlet
Modem/
Phone/Fax
9
To Computer USB
Port
CONNECT INTERFACE CABLE
Data Port BR24BP Battery Pack
Computer
12 INSTALL SOFTWARE ON
COMPUTER There are four status indicators (lights) on the front
panel of the Back-UPS (On Line, On Battery, Overload,
and Replace Battery).
On Line (green) - is lit whenever utility power is
powering the Battery Backup outlets.
On Battery (yellow) - is lit whenever the battery of
the Back-UPS is powering equipment connected to the
Battery Backup Outlets.
Four Beeps Every 30 Seconds - this alarm is
sounded whenever the Back-UPS is running On
Battery. Consider saving work in progress.
Overload (red) - is lit whenever power demand has
exceeded the capacity of the Back-UPS.
Continuous Tone - this alarm is sounded
whenever the Battery Backup outlets are
overloaded.
Circuit Breaker - the circuit breaker button
located on the rear panel of the Back-UPS will
stick out if an overload condition forces the Back-
UPS to disconnect itself from utility power. If the
button sticks out, disconnect non-essential
equipment. Reset the circuit breaker by pushing
the button inward.
Replace Battery (red) - is lit whenever the battery is
near the end of its useful life, or if the battery is not con-
nected (see above). A battery that is near the end of its use-
ful life has insufficient run-time and should be replaced.
Chirps for 1 Minute Every 5 Hours - this
alarm is sounded whenever the battery has failed
the automatic diagnostic test.
Note: Allow the Back-UPS to charge for a full
eight (8) hours prior to use.
Press the front panel Power ON/OFF switch and
observe that the following events occur after
pressing and releasing the switch:
The green On Line indicator flashes.
The yellow On Battery indicator lights while
a Self-Test is being performed.
When Self-Test has successfully completed,
only the green On Line indicator will be lit.
If the battery cartridges are not connected (see
Step 3 above), the green On Line indicator
and red Replace Battery indicators will light.
The Back-UPS will also emit a chirping
sound.
Continuous Beeping - this alarm is sounded
whenever a low battery condition is reached.
Battery run-time is very low. Promptly save any
work in progress and exit all open applications.
Shutdown the operating system, computer and
the Back-UPS.
NOTE: Macintosh Users - for full USB performance,
use OS 9.22 or higher.
If Autoplay is not enabled on the computer, proceed
as follows:
1. On the computer desktop of the display, double-
click on My Computer.
2. Double-click on the CD-ROM drive icon and
follow the on-screen instructions.
If the rear panel Building Wiring Fault (red) indicator
is lit, a potential shock hazard exists due to one of the
following conditions:
• Open or high resistance ground
• Hot or neutral polarity reversed
• Overloaded neutral circuit
Improper building wiring should be corrected by a
qualified electrician. Do not use the Back-UPS until
the condition that caused the fault is corrected.
Note: Improper building wiring will not prevent the
Back-UPS from operating, but it will limit its
protection capability.
11 SWITCH ON THE BACK-UPS
10 ORIENTATION
13 GROUND
The Back-UPS features a transient
voltage surge-suppression (TVSS)
screw for connecting the ground
lead on additional surge
suppression devices such as
network and data line surge
protectors.
Wall
Outlet
Modem/
Phone/Fax
TVSS GND
From Data Line
TVSS
Follow the
on-screen
instructions.
On Line
On Battery
Overload
Replace Battery
RJ-45USB
STATUS INDICATORS AND ALARMS
32 - 104oF (0 - 40oC)
A
3
24 inches
60 cm
5CONNECT BACK-UPS TO
BATTERY PACK
Data Port
Building
Wiring Fa ult
Wall
Outlet
Modem/
Phone/Fax
TVSS GND
BR24 BP Battery Pack
MODEM/FAX
INSTALL PEDESTAL
EXTENDER
Align
Slide Together
INSTALL BACK-UPS AND
BATTERY PACK IN PEDESTAL
B


Produkt Specifikationer

Mærke: APC
Kategori: Uafbrydelig strømforsyning (UPS)
Model: Back-UPS XS 1500

Har du brug for hjælp?

Hvis du har brug for hjælp til APC Back-UPS XS 1500 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Uafbrydelig strømforsyning (UPS) APC Manualer

Uafbrydelig strømforsyning (UPS) Manualer

Nyeste Uafbrydelig strømforsyning (UPS) Manualer