APC BK350EI Manual
APC
Uafbrydelig strømforsyning (UPS)
BK350EI
Læs nedenfor 📖 manual på dansk for APC BK350EI (2 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne guide var nyttig for 18 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
USB
RJ-45
In situations where the Back-UPS or connected equipment appears too sensitive to input voltage, it may be
necessary to adjust the transfer voltage. This is a simple task requiring use of the front panel pushbutton. To
adjust the transfer voltage, proceed as follows:
1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a Standby Mode (no indicators lit).
2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the Back-UPS will flash to
acknowledge going into Programming Mode.
3. The Back-UPS will then indicate its current Sensitivity Setting, as shown in the following table.
4. To select the Low Sensitivity setting, press the pushbutton until the yellow indicator is flashing.
5. To select the Medium Sensitivity setting, press the pushbutton until the yellow and red indicators (second and
third from the top) are flashing.
6. To select the High Sensitivity setting, press the pushbutton until yellow and both red indicators (bottom three)
are flashing.
7. To exit without changing the Sensitivity Setting, press the pushbutton until the green indicator is flashing.
8. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds, the Back-UPS will exit
Programming Mode; all indicators will extinguish.
Indicators
Flashing
Sensitivity
Setting
Input Voltage
Range
(for utility
operation)
Use When
1
(yellow)
Low 160 - 278 Vac Input voltage is extremely low or
high. Not recommended for computer
loads.
2
(yellow, and red)
Medium
(factory default)
180 - 266 Vac Back-UPS frequently goes On
Battery.
3
(yellow, red, and red)
High 196 - 256 Vac Connected equipment is sensitive to
voltage fluctuations (recommended).
Back-UPS™
350/500/650
User’s Manual
990-9237 3/04
Installation
2Connect Equipment
The rear panel of the Back-UPS consists of the
following elements:
Battery Back Up Outlets (qty. of 3). These
outlets provide battery back-up, surge protection,
and Electro-magnetic Interference (EMI) filtering.
In case of power outage, battery power is
automatically provided to these outlets. Power
(utility or battery) is not supplied to these outlets
when the Back-UPS is switched Off. Connect a
computer, monitor, and external disk or CD-ROM
drive to these outlets.
Surge Only Outlet. This outlet is always On
(when utility power is available) and is not
controlled by the On/Off switch. This outlet does
not provide power during a power outage. Connect
a printer, fax machine or scanner to this outlet.
Note: Allow the Back-UPS to charge for a full eight
hours prior to use.
Press the push-button on the front panel of the Back-
UPS.
Observe that the following events occur after
pressing and releasing the push-button:
• The green On-Line indicator flashes.
• The yellow On Battery indicator lights while
the Self-Test is being performed.
• When Self-Test has successfully completed,
only the green On Line indicator will be lit.
• If the internal battery is not connected, (see Step
1 above) the green On Line indicator and red
Replace Battery indicator will light. The Back-
UPS will also emit a chirping sound.
ON LINE
ON BATTERY
OVERLOAD
REPLACE BATTERY
5Connect USB Cable
There are four status indicators (lights) on the front
panel of the Back-UPS (On Line, On Battery,
Overload, and Replace Battery).
On Line (green) - is lit whenever utility
power is powering the Battery Backup
outlets.
ON LINE
ON BATTERY
OVERLOAD
REPLACE BATTERY
On Battery (yellow) - is lit whenever
the battery of the Back-UPS is powering
equipment connected to the Battery
Backup Outlets.
Four Beeps Every 30 Seconds - this
alarm is sounded whenever the Back-
UPS is running On Battery. Consider
saving work in progress.
Continuous Beeping - this alarm is
sounded whenever a low battery
condition is reached. Battery run-time
is very low. Promptly save any work
in progress and exit all open
applications. Shutdown the operating
system, computer and the Back-UPS.
Overload (red) - is lit whenever
power demand has exceeded the capac-
ity of the Back-UPS.
Continuous Tone - this alarm is
sounded whenever the Battery Backup
outlets are overloaded.
Circuit Breaker - the circuit
breaker button located on the rear
panel of the Back-UPS will stick
out if an overload condition forces
the Back-UPS to disconnect itself
from utility power. If the button
sticks out, disconnect non-
essential equipment. Reset the
circuit breaker by pushing the
button inward.
1Placement / Power 3Connect the Phone
Line to Surge Protection
Avoid placing the Back-UPS in:
• Direct sunlight
• Excessive heat
• Excessive humidity or in contact with fluids
of any type
Plug the Back-UPS into a wall outlet, as shown.
• The Back-UPS charges the internal battery
any time it is connected to a wall outlet.
Your computer’s power cord.
The telephone ports provide lightning surge
protection for any device connected to the telephone
line (computer, modem, fax or telephone). The
telephone ports are compatible with Home Phoneline
Networking Alliance (HPNA) and Digital Subscriber
Line (DSL) standards, as well as all modem data
rates. Connect as shown.
Wall Outlet
Modem/Phone/Fax
Replace Battery (red) - is lit when-
ever the battery is near the end of its use-
ful life, or if the battery is not connected
(see above). A battery that is near the
end of its useful life has insufficient run-
time and should be replaced.
Chirps for 1 Minute Every 5 Hours -
this alarm is sounded whenever the
battery has failed the automatic
diagnostic test.
CS
®
to the Back-UPS
4Switch on the
Back-UPS
Replace the Internal Battery
To replace the internal battery, proceed as follows:
Note: Replacing the battery is a safe procedure. However, small sparks may occur
during the process. This is normal.
Place the unit on its side. Slide the battery
compartment cover upward and off of the UPS.
21
3 4
Align the battery compartment cover with the
grooves in the UPS. Slide the cover down
until it locks.
Pull the battery out, exposing the battery
terminals and wires. Disconnect the wires from
the terminals.
Slide the new battery into the battery
compartment. Connect the battery wires to the
terminals as follows:
Black wire to Ground (-) terminal
Red wire to Positive (+) terminal
and Install Software
(optional)
NOTE: Macintosh Users - for full USB
performance, use Mac OS 10.1.5 or higher.
If Autoplay is not enabled on the computer,
proceed as follows:
1. On the computer desktop of the display,
double-click on My Computer.
2. Double-click on the CD-ROM drive icon and
follow the on-screen instructions.
Follow the
on-screen
instructions.
Status Indicators and Alarms
Order Replacement Battery
The typical battery lifetime is 3-6 years (depending on the number of discharge cycles and operating
temperature). A replacement battery can be ordered over the phone from APC, or the battery can be ordered
on-line from the APC web site (http://www.apc.com, a valid credit card is required).
When ordering, please specify Battery Cartridge RBC2 (Back-UPS 350/500) or RBC17 (Back-UPS 650).
Transfer Voltage and Sensitivity Adjustment (optional)
APC, Back-UPS, and PowerChute are registered trademarks of American Power Conversion.
All other trademarks are property of their respective owners.
Produkt Specifikationer
Mærke: | APC |
Kategori: | Uafbrydelig strømforsyning (UPS) |
Model: | BK350EI |
Bredde: | 91 mm |
Dybde: | 284 mm |
Højde: | 165 mm |
Vægt: | 6320 g |
Produktfarve: | Beige |
Batterispænding: | 12 V |
Batterikapacitet: | 7 At |
Pakkevægt: | 7050 g |
Pakkedybde: | 368 mm |
Pakkebredde: | 241 mm |
Pakkehøjde: | 178 mm |
USB-port: | Ja |
Batteriteknologi: | Blybatterier (VRLA) |
Formfaktor: | Tower |
Opbevaringstemperatur (T-T): | -15 - 45 °C |
Relativ luftfugtighed ved drift (H-H): | 0 - 95 % |
Relativ luftfugtighed ved opbevaring (H-H): | 0 - 95 % |
Driftstemperatur (T-T): | 0 - 40 °C |
Hurtig installationsvejledning: | Ja |
Kabler inkluderet: | Phone (RJ-11),USB cable |
Udgangseffekt: | 210 W |
Certificering: | C-tick, CE, EN 50091-1, EN 50091-2,GOST, VDE, PEP, EOLI |
Produkter pr. palle: | 48 stk |
Filtrering: | Ja |
LED-indikatorer: | Erstatningsbatteri |
Kabellængde: | 1.83 m |
Harmoniseret systemkode (HS): | 85078000 |
Batterilevetid (maks.): | 6 År |
Opladningstid for batteri: | 6 t |
Bæredygtighedscertifikater: | RoHS,ENERGY STAR |
Medfølgende software: | PowerChute Personal Edition |
Driftshøjde: | 0 - 3000 m |
Ikke-drift højde: | 0 - 15000 m |
Indgangsfrekvens: | 50/60 Hz |
Garantibevis: | Ja |
Batteriets kapacitet: | 116 VAh |
Lydalarmer: | Ja |
Strømbeskyttelsesfunktioner: | Overbelastning |
Effektivitet: | 98.6 % |
Strømstik: | C14 forbinder |
Software CD: | Ja |
Nominel udgangsspænding: | 230 V |
Nominel indgangsspænding: | 230 V |
AC udgange, antal: | 4 AC stikkontakt(er) |
AC stikkontakt typer: | C13 forbinder |
Overspænding energivurdering: | 310 J |
Indgående driftsspænding (maks.): | 266 V |
Output strømkapacitet (VA): | 0.35 kVA |
Indgående driftsspænding (min.): | 180 V |
Udgangs driftsspænding (min.): | - V |
Udgangs driftsspænding (maks.): | - V |
UPS topologi: | Standby (offline) |
Beskyttelsesfunktioner mod strømstød: | Digital Subscriber Line (DSL),Fax,Modem,Telephone |
Strøm (maks.): | 7 A |
Regulering af udgangsfrekvens: | 47 - 63 Hz |
Holdetid (maks.): | 10 ms |
Beskyttelse ved overspænding: | Ja |
Holdetid (min.): | 6 ms |
Hørbare alarmtilstande: | Low battery alarm,Overload alarm |
Typisk backup tid ved halv styrke: | 22.1 min. |
Typisk backup tid ved fuld styrke: | 8.6 min. |
Automatisk batteritest: | Ja |
Antal udgående IEC stik: | 2 |
Har du brug for hjælp?
Hvis du har brug for hjælp til APC BK350EI stil et spørgsmål nedenfor, og andre brugere vil svare dig
Uafbrydelig strømforsyning (UPS) APC Manualer
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
24 September 2024
24 September 2024
24 September 2024
17 September 2024
17 September 2024
5 Maj 2024
Uafbrydelig strømforsyning (UPS) Manualer
- Uafbrydelig strømforsyning (UPS) Ikea
- Uafbrydelig strømforsyning (UPS) Siemens
- Uafbrydelig strømforsyning (UPS) CyberPower
- Uafbrydelig strømforsyning (UPS) HP
- Uafbrydelig strømforsyning (UPS) GYS
- Uafbrydelig strømforsyning (UPS) Lenovo
- Uafbrydelig strømforsyning (UPS) Adj
- Uafbrydelig strømforsyning (UPS) Wago
- Uafbrydelig strømforsyning (UPS) Gembird
- Uafbrydelig strømforsyning (UPS) Tripp Lite
- Uafbrydelig strømforsyning (UPS) Digitus
- Uafbrydelig strømforsyning (UPS) Aiptek
- Uafbrydelig strømforsyning (UPS) EnerGenie
- Uafbrydelig strømforsyning (UPS) Voltcraft
- Uafbrydelig strømforsyning (UPS) LevelOne
- Uafbrydelig strømforsyning (UPS) Eaton
- Uafbrydelig strømforsyning (UPS) BlueWalker
- Uafbrydelig strømforsyning (UPS) V7
- Uafbrydelig strømforsyning (UPS) Steren
- Uafbrydelig strømforsyning (UPS) Salicru
- Uafbrydelig strømforsyning (UPS) Approx
Nyeste Uafbrydelig strømforsyning (UPS) Manualer
15 November 2024
8 November 2024
8 November 2024
22 Oktober 2024
22 Oktober 2024
21 Oktober 2024
2 Oktober 2024
24 September 2024
23 September 2024
23 September 2024