Safety and General Instructions
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should
be followed during installation and maintenance of the product.
Read the user documentation to become familiar with the equipment before
trying to install or operate it.
Switch off the input power before connecting or disconnecting the wires.
Use RED color wire for +ve and BLACK color wire for ve connections.
Use insulated pin type lugs to be sure that the wire strands do not touch any metallic
surface during connection/disconnection.
Be sure that the wires do not touch any metallic surface during connection/
disconnection.
Be sure to connect the wires to the power supply unit first and then to battery pack(s).
While disconnecting wires, be sure to disconnect the wires at battery pack(s) first and
then at the power supply unit.
Allow a minimum space of 50 mm above the unit, 180 mm below the unit and 10 mm
lateral distance from other devices to be sure of sufficient cooling.
CAUTION: The enclosure can reach temperatures that exceed the burn thresholds for
touchable surfaces, depending on the ambient temperature and load.
Do not introduce any objects into the power supply unit.
Specifications
Environmental
Physical
Input
Output
Certification and Standards
IEC/EN/BS/UL 62368-1, CSA-C22.2 No. 62368-1, IEC/EN 60950-1, UL 508,
CSA C22.2 No. 14, IEC/EN 61010-1.
cTUVus CE, UKCA, GB 4943.1, CQC, EN 55032, EN55035, EN IEC 61000-6-2,
EN IEC 61000-6-4, EN IEC 61204-3, FCC 47 CFR Part 15, Subpart B & ICES-003 Issue 7
Front Panel Features
Installation
Mounting
NOTE: Be sure that the input/output terminal block is at the bottom while mounting the
power supply unit on a 35 mm DIN rail.
1. Locate the top hook of the rail
mounting system (on the unit)
with the unit slightly tilted
upwards.
2. Rotate the unit in clockwise
direction till the latch of the rail
mount system snaps on to the
DIN rail and the unit cannot be
rotated any further.
3. Shake the unit slightly to be
sure that it is securely mounted
on the DIN rail.
Dismounting
1. Release the latch of the rail
mount system (on the unit) by
pulling it downwards using a
screw driver.
2. Tilt the unit upwards till the latch
is free from the DIN rail.
3. Slide the unit upwards till the
top hook gets free from the DIN
rail.
Dry contact details
All dry contacts (Pin3 to Pin10) are normally closed during operation and will open during
an event.
NOTE:
NC = Normally Closed; NO = Normally Open; NA = Not Applicable.
To insert wires into the Dry Contact terminals, press the locking lever (
) using a
suitable screwdriver and insert the wire into the terminal (). Remove the screwdriver
to secure the wire to the terminal.
Ambient temperature Operating –15 to +50 °C
Storage –15 to +70 °C
Humidity 5 to 95% (Non condensing)
Altitude Operating 3000 m (Max.)
Storage 3000 m (Max.)
Audible Noise < 40 db
International Protection Code IP 20
Operating Protection Class Class II
Dimensions without packaging (H x W x D) 129 x 40 x 119 mm
(5.08 x 1.57 x 4.69 in)
Dimensions with packaging (H x W x D) 190 x 57x 188 mm
(7.47 x 2.23 x 7.39 in)
Weight without packaging 0.5 kg
(1.1 lb)
Weight with packaging 0.7 kg
(1.54 lb)
240 W 480 W
Model BVS240XDPDR BVS480XDPDR
Nominal input voltage 24 VDC
Voltage Range 21.6 – 28.6 VDC
Nominal Current 10 A 20 A
Runtime at full load (with 1 battery pack) 10 min at 10 A load 3 min at 20 A load
Efficiency at Nominal Voltage (Bypass mode,
battery fully charged) >95%
Over current / Short circuit protection 40 A Fuse
240 W 480 W
Nominal output voltage UN / tolerance 24 VDC
Switch On time (On delay time typical) < 1 s
Output current 10 A 20 A
Output over current limit 10.5 A< OCP<13 A 20.5 A<OCP<26 A
Short circuit protection Yes
Over temperature protection Yes
No. of units series connection No
No. of units parallel connection No
(+) Battery terminal
(–) Battery terminal
(–) Output terminal
(+) Output terminal
(–) Input terminal
(+) Input terminal
Dry contact terminals
Status LED - Red
Status LED - Green
240 W 480 W
oem0343a
Pin1 Remote On/Off. Connect Normally Open
Push to On button to this contact.
Pin2
Pin3 On-Battery mode
Pin4
Pin5 Replace battery
Pin6
Pin7 Battery disconnected
Pin8
Pin9 Low battery
Pin10
Locking lever
Terminal
Mode of Operation Line
Mode
Battery
Mode
Battery Mode
Low Battery
Line Mode
Battery disconnected
Replace
Battery
Condition
Remote On/Off NA NA NA NA NA
On-Battery NC NO NO NC NC
Replace Battery NC NC NC NC NO
Battery Disconnected NC NC NC NO NC
Low Battery NC NC NO NC NC
oem0344a
oem
0345a
 
oem0346a
User Manual Easy UPS DIN Rail
Mount DC to DC Power Supply
BVS240XDPDR/BVS480XDPDR


Produkt Specifikationer

Mærke: APC
Kategori: Uafbrydelig strømforsyning (UPS)
Model: BVS240XDPDR
Bredde: 40 mm
Dybde: 129 mm
Højde: 119 mm
Vægt: 500 g
Produktfarve: Grå
Udgangseffekt: 240 W
Harmoniseret systemkode (HS): 85078000
Indgående driftsspænding (maks.): 28.6 V
Output strømkapacitet (VA): 0.24 kVA
Indgående driftsspænding (min.): 21.6 V
Udgangs driftsspænding (min.): 24 V
Udgangs driftsspænding (maks.): 24 V

Har du brug for hjælp?

Hvis du har brug for hjælp til APC BVS240XDPDR stil et spørgsmål nedenfor, og andre brugere vil svare dig




Uafbrydelig strømforsyning (UPS) APC Manualer

APC

APC Back-UPS BN4001 Manual

12 Oktober 2024
APC

APC RBC9 Manual

24 September 2024
APC

APC RBC22 Manual

24 September 2024
APC

APC AP9626 Manual

24 September 2024
APC

APC 66077 Manual

17 September 2024
APC

APC 66057 Manual

17 September 2024

Uafbrydelig strømforsyning (UPS) Manualer

Nyeste Uafbrydelig strømforsyning (UPS) Manualer