Inventory
Safety and General Information
Inspect the package contents upon receipt. Notify the
carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before
installing the UPS.
This unit is designed for low power devices less than 75 Watts. When the UPS is
on battery, the unit will shut down automatically to protect itself once the load on
the UPS is greater than 75Watts.
This UPS is intended for indoor use only.
Do not operate this UPS in direct sunlight, in contact with fluids, or where there is
excessive dust or humidity.
Be sure the air vents on the UPS are not blocked. Allow adequate space for proper
ventilation.
The battery typically lasts for three to five years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality AC power, and frequent
short duration discharges will shorten battery life.
Connect the UPS power cable directly to a wall outlet. Do not use surge protectors
or extension cords.
Specifications
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
Connect Equipment
Battery Backup Outlets
Battery backup outlets provide protection to connected equipment when the
Back-UPS is turned on and connected to AC power.
Battery backup outlets receive power from the Back-UPS for a limited period of time
when a power outage, or brownout condition occurs.
Battery backup outlets provide protection from power surges or spikes.
Connect a broadband modem and wireless router to the outlets. Voice over IP (VOIP)
phones (if applicable) should also be plugged into battery backup outlets.
To maximize runtime in the event of a power outage only connect networking
equipment to battery backup outlets.
This UPS is designed to sustain low power devices for extended periods of time.
When the UPS is on battery, the unit will shut down automatically if the load on the
UPS exceeds 75Watts. Low power devices include modems, routers, USB chargers
(5W and 10W), VOIP and cordless phones.
Turn On the Back-UPS
Press the POWER ON button located on the top of the Back-UPS. The Power On/
Replace Battery LED will illuminate and a single short beep will be audible to
indicate that the Back-UPS is providing protection for connected equipment.
The Back-UPS battery charges fully during the first 16 hours while connected to AC
power. The Back-UPS battery will charge while the Back-UPS is switched on or off
and is connected to AC power. Do not expect full battery run capability during the
initial charge time.
Status Indicators
Wall Mount Installation
Horizontal installation, use 2 screws 3-15/16” (100 mm) apart.
Allow 5/16” (8 mm), of the screw to protrude from the wall.
Input Voltage 120 Vac Nominal
Frequency 50/60 Hz + 3
Brownout Transfers 92 Vac Typical
Over-voltage Transfer 139 Vac Typical
Output UPS Capacity
(3 battery backup outlets)
125 VA, 75 W
Total Amperage (all outlets) 1.04 A (including UPS output)
Voltage - On Battery 115 Vac ± 8%
Frequency - On Battery 50/60 Hz + 1
Transfer Time 6 ms Typical, 10 ms maximum
Protection
and
Filtering
AC Surge Protection Full time, 90 Joules
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery Type Sealed, maintenance-free, lead acid
RBC153
Average Life 3 - 5 years depending on the number of
discharge cycles and environmental
temperature
Physical Net Weight 5.51 lb (2.5 kg)
Dimensions
Length x Width x Height
8.9 in x 4.1 in x 5.2 in
22.5 cm x 10.5 cm x 13.2 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature 5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
Remove the “Stop! Connect the
Battery” label that covers the outlets.
Press the battery compartment cover
release tabs located on the rear side of the
unit. Slide the battery cover off.
Connect the battery cable securely to
the battery terminal. It is normal for small
sparks to be seen when the battery cable is
connected to the battery terminal.
Reinstall the battery compartment cover.
Be sure that the release tab locks into place.
bu374a
bu379a
bu375a
bu376a
bu378a
Status Power Button
LED
Audible
Indicator On
Audible Indicator
Terminates
Power On
The Back-UPS is
supplying AC power to
connected equipment.
The LED
illuminates green.
None N/A
On Battery
Back-UPS supplying
battery power to battery
backup outlets.
The LED
illuminates green.
The LED flashes
once at the end of
every 2 seconds.
Back-UPS
beeps for 2
seconds
when
entering
battery
mode.
Beeping stops at the
end of the first two
seconds. A constant
beep at the initial
two seconds
indicates the Back-
UPS has entered the
battery mode.
Low Battery warning
The Back-UPS is
supplying battery power to
the battery backup outlets
and the battery is near a
total discharge state.
The LED
illuminates green
and flashes in
rapid succession.
The Back-
UPS emits
rapid
beeping,
every
1/2 second.
Beeping stops when
AC power is
restored or the Back-
UPS is turned off.
Replace Battery
The battery is
disconnected.
The battery needs to be
charged, or replaced.
The LED
alternately
illuminates green-
red.
Constant
tone
Constant
tone
Back-UPS is turned
off.
Overload Shutdown
While on battery power an
overload condition has
occurred in one or more of
the battery backup outlets
while the Back-UPS is
operating on battery
power.
None Constant
tone
Back-UPS is turned
off.
Sleep Mode
While on battery power
the battery is completely
discharged. The
Back-UPS will “awaken”
once AC power is
restored.
None The Back-
UPS beeps
once every
four seconds.
The beeping stops
when:
AC power is
restored
If AC power is not
restored within 32
seconds
The Back-UPS is
turned off
bu377a
Wall-mounting Template
bu3
8
0
a
100 mm
3 in.
User Manual Back-UPS Connect BGE 70/70-CA 120 Vac


Produkt Specifikationer

Mærke: APC
Kategori: Uafbrydelig strømforsyning (UPS)
Model: Connect BGE70
Bredde: 105 mm
Dybde: 225 mm
Højde: 132 mm
Vægt: 2500 g
Produktfarve: Hvid
Pakkevægt: 2800 g
Pakkedybde: 299 mm
Pakkebredde: 164 mm
Pakkehøjde: 204 mm
Batteriteknologi: Blybatterier (VRLA)
Formfaktor: Kompakt
Opbevaringstemperatur (T-T): -15 - 45 °C
Relativ luftfugtighed ved drift (H-H): 0 - 95 %
Relativ luftfugtighed ved opbevaring (H-H): 0 - 95 %
Driftstemperatur (T-T): 0 - 40 °C
Udgangseffekt: 75 W
Opladningstid for batteri: 16 t
Driftshøjde: 0 - 3000 m
Indgangsfrekvens: 50/60 Hz
Strømstik: NEMA 1-15P
AC udgange, antal: 3 AC stikkontakt(er)
AC stikkontakt typer: NEMA 1–15R
Overspænding energivurdering: 120 J
Indgående driftsspænding (maks.): 140 V
Output strømkapacitet (VA): 0.125 kVA
Indgående driftsspænding (min.): 90 V
Udgangs driftsspænding (min.): 120 V
Udgangs driftsspænding (maks.): 120 V
Strøm (maks.): 4 A
Bølgeform: Firkant
Typisk backup tid ved halv styrke: - min.
Typisk backup tid ved fuld styrke: - min.

Har du brug for hjælp?

Hvis du har brug for hjælp til APC Connect BGE70 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Uafbrydelig strømforsyning (UPS) APC Manualer

APC

APC Back-UPS BN4001 Manual

12 Oktober 2024
APC

APC RBC9 Manual

24 September 2024
APC

APC RBC22 Manual

24 September 2024
APC

APC AP9626 Manual

24 September 2024
APC

APC 66077 Manual

17 September 2024
APC

APC 66057 Manual

17 September 2024

Uafbrydelig strømforsyning (UPS) Manualer

Nyeste Uafbrydelig strømforsyning (UPS) Manualer