Arista EDU Ultra 200 Manual

Arista Ikke kategoriseret EDU Ultra 200

Læs nedenfor 📖 manual på dansk for Arista EDU Ultra 200 (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 5 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Recommended Agitation: Agitate continuously for first 30 seconds of devel-
opment, then provide agitation of 5 to 7 inversion cycles for 5 seconds every
30 seconds for remainder of development time.
Where continuous agitation is used for rotary processor, reduce the developing
times by 15%.
Development times may need adjusting to suit individual processing systems and
working practices. If an established system is producing good results, adjust the
recommended development times until the desired contrast is obtained.
This material will be replaced if found defective in manufacture, labeling or
packaging. Except for such replacement, this product is sold witout warranty
or other liability.
Developer and film manufacturers can and do change their product
specifications from time to time and the development times may
change as a result.
For more information regarding Arista.EDU ULTRA
®B&W films contact:
FREESTYLE PHOTOGRAPHIC SUPPLIESTM
5124 Sunset Boulevard Hollywood, CA 90027
800.292.6137 toll free phone • 323.660.3460 phone
www.freestylephoto.biz info@freestylephoto.biz
Made in Czech Republic
DEVELOPER DILUTION TIME @
68˚F / 20˚C
Arista®76 Powder Stock 5 - 6
Arista®76 Powder 1:1 8 - 9
Arista®Premium Powder Stock 7
Arista®Premium Powder 1:1 8
Arista®Liquid Film Developer
Working Solution
7 1/2
Arista®Premium Liquid Developer 1:9 7 1/2
Marathon®Film Developer 1:9 5
Ilford ID-11, Kodak D-76 Stock 5 - 6
Ilford ID-11, Kodak D-76 1:1 8 - 9
Kodak XTOL (Straight) 6
Kodak TMAX Developer 1:4 5 - 6
Kodak HC 110 1:31 NR
Agfa Rodinal 1:25 5
ARISTA.EDU ULTRA®BLACK & WHITE FILM
ISO 200/24°
DEVELOPING INSTRUCTIONS:
Arista.EDU Ultra®B&W film is compatible with all major
processing systems. Recommended developing times are
for normal contrast negatives (based on intermittent
agitation.) All developing times are standardized for 68˚F /
20˚C. Your developing time may vary based on environment
and equipment used.


Produkt Specifikationer

Mærke: Arista
Kategori: Ikke kategoriseret
Model: EDU Ultra 200

Har du brug for hjælp?

Hvis du har brug for hjælp til Arista EDU Ultra 200 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Arista Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Gigabyte

Gigabyte ODIN GT 550W Manual

23 November 2024
Stamos

Stamos S-PLASMA 60U Manual

23 November 2024
Velbus

Velbus VMBPIRO-W-20 Manual

23 November 2024
Honor

Honor 90 Pro Manual

23 November 2024
Honor

Honor 80 SE Manual

23 November 2024
Medela

Medela Safe & Dry Manual

22 November 2024
Jane

Jane First Potty Manual

22 November 2024