Quick Start Guide
Modbus Hardened Serial Server
LES431A
Order toll-free in the U.S.:
Call 877-877-BBOX
(outside U.S. call 1-724-746-5500)
FREE technical support
24 hours a day, 7 days a week:
Call 724-746-5500 or
fax 724-746-0746
Mailing address:
Black Box Corporation
1000 Park Drive
Lawrence, PA 15055-1018
Web site: www.blackbox.com
E-mail: info@blackbox.com
Customer
Support
Information
LES431A Quick Start Guide
Step 12. Set up Port 1 ID remap.
• Only use this screen to remap “Modbus Slave IDs.”
• On each line, select the range of IDs to re-route. In
the first box, enter the first serial port of the range
to remap from. Valid port IDs range from 1 to 247.
• Second box: Enter the last serial port of the range to
remap.
• Third box: Enter starting ID of the range to remap to.
• Fourth box: Auto fills based on ranges entered in the
first three columns.
Step 13. Set up Modbus ID routing.
• Only use this screen to re-route “Modbus Slave IDs.”
• On each line, select the range of IDs to re-route. In
the first box enter the starting ID. Valid IDs range
from 1 to 247.
• Second box: Enter the last ID of the range to
re-route.
• Third box: Enter the “IP Address” or “Port” that has
slave devices attached.
• Fourth box: Shows the IP address of the slave device,
if an IP address is chosen in the third box.
Step 14. Set up Modbus priority.
• Only use this screen to set “Modbus Priority.”
• Enter up to five different priorities, based on
“Originating IP Address,” “Modbus ID,” “Modbus
Function Code,” or a combination of these.
• “IP Address” sets a static IP address for the Modbus
Hardened Serial Server.
• “Modbus ID” has a valid range from 1 to 247.
• Function code has a valid range from 1 to 99.
Step 15. Save and logout.
• If you have completed the configuration, click
“Save” to save the configuration to the serial server.
• To logout, click the “Logout” button.
Step 1. Check for all required hardware.
Your package includes:
• 1-Port Modbus Hardened Serial Server
• CD-ROM containing software
• This Quick Start Guide
You will also need:
• Network and serial cables (not included)
• Power supply (not included)
Step 2: Install the hardware.
• Connect a 10- to 48-VDC (58 VDC max.)
power supply (4.0 W required).
• Connect the network cable from the serial
server to a network drop using a standard
serial cable.
• Connect the serial device to the RS-232
DB9 or terminal block serial connector with a
straight-through cable for a DCE device or a
null-modem cable for a DTE device.
NOTE: UL® requires one conductor per terminal,
28 to 16 AWG copper-wire, tightening
torque of 5 kg-cm, and 105° C rating
sized for 60° C ampacity.
LES431A Quick Start Guide, rev. 1
LES431A Quick Start Guide
Step 16. Test and verify operation.
• The primary check for normal operation is the device
LEDs. See Step 3 in this document for more
information.
• For advanced information, see the “Modbus
Configuration Manager” menu, at the top of the
Modbus Hardened Serial Server Manager screen.
• Select “Diagnostic” to check communications status
with the Modbus Hardened Serial Server, then select
the device for which you want to check
communications data.
• A report of reply times and ping statistics is
generated and can be saved.
• Select “Monitor” to review activity logs of attached
LES431A devices, then select the device for which
logged information is needed.
• Logged information includes “Time,” “Source and
Destination,” “Type of event,” “Subscriber ID,”
“Data collected,” and “Information” the Modbus
Hardened Serial Server software has gathered since
the current login of the affected device.
Produkt Specifikationer
Mærke: | Black Box |
Kategori: | Server |
Model: | LES431A |
Kode for international beskyttelse (IP): | IP30 |
Vægt: | 100 g |
Produktfarve: | Sort |
Opbevaringstemperatur (T-T): | -40 - 85 °C |
Relativ luftfugtighed ved drift (H-H): | 10 - 95 % |
Ethernet LAN-porte (RJ-45): | 1 |
Driftstemperatur (T-T): | -40 - 80 °C |
Dimensioner (BxDxH): | 81 x 119 x 30 mm |
Certificering: | FCC Part 15, Class A, CE, NEMA TS2, UL Class 1, Division 2, Groups A, B, C, D |
Kabelteknologi: | 10/100Base-T(X) |
Netværksstandarder: | IEEE 802.3 |
Understøttede netværksprotokoller: | TCP, IPv4, UDP, ARP, HTTP 1.0, ICMP/PING, DHCP/BOOTP, DHCP,, TCP |
LED-indikatorer: | Ja |
Indgangsspænding: | 10 - 58 V |
Understøttede Windows-operativsystemer: | Windows 7,Windows Vista,Windows XP Home,Windows XP Home x64,Windows XP Professional,Windows XP Professional x64 |
Strømforbrug: | 4000 mA |
Understøttede operativsystemer til servere: | Windows Server 2003,Windows Server 2008 |
Auto MDI/MDI-X: | Ja |
Flowkontrol support: | Ja |
Seriel grænsefladetype: | RS-232/422/485 |
Antal serielle porte: | 1 |
Baud hastighed: | 230400 Kbit/s |
Data-bits: | 5,6,7,8 |
RS-232 signaler: | CTS,DCD,DSR,DTR,GND,RTS,RXD,TXD |
RS-422 signaler: | GND |
RS-485 signaler: | Data+,Data-,GND |
Stop bits: | 1,1.5,2 |
Dataoverførselshastighed: | 0.234 Mbit/s |
Har du brug for hjælp?
Hvis du har brug for hjælp til Black Box LES431A stil et spørgsmål nedenfor, og andre brugere vil svare dig
Server Black Box Manualer
23 August 2024
31 Juli 2024
22 Juli 2024
19 Juli 2024
27 Februar 2024
18 Juli 2023
23 December 2022
30 Oktober 2022
5 Oktober 2022
Server Manualer
- Server QNAP
- Server Bosch
- Server Acer
- Server Sony
- Server HP
- Server D-Link
- Server Asus
- Server Gigabyte
- Server Toshiba
- Server Lenovo
- Server Abus
- Server Planet
- Server TRENDnet
- Server Buffalo
- Server Medion
- Server Linksys
- Server Megasat
- Server Cisco
- Server Seagate
- Server Netgear
- Server Tripp Lite
- Server Western Digital
- Server Technics
- Server Digitus
- Server Dell
- Server Fujitsu
- Server MSI
- Server NEC
- Server APC
- Server LevelOne
- Server FLIR
- Server ZyXEL
- Server Eaton
- Server ELAC
- Server Synology
- Server Hikvision
- Server Monacor
- Server AVerMedia
- Server Asustor
- Server Kramer
- Server Hanwha
- Server LaCie
- Server Naim
- Server Fantec
- Server Provision-ISR
- Server Quantum
- Server Axis
- Server ACTi
- Server Digi
- Server ATen
- Server Teo
- Server Vimar
- Server Smart-AVI
- Server Intel
- Server Supermicro
- Server StarTech.com
- Server Conceptronic
- Server Rocstor
- Server IStarUSA
- Server Blackmagic Design
- Server Lindy
- Server Veritas
- Server Promise Technology
- Server Sitecom
- Server HGST
- Server AMX
- Server Intellinet
- Server Iomega
- Server Silverstone
- Server Geovision
- Server Ernitec
- Server KanexPro
- Server Gefen
- Server Moxa
- Server C2G
- Server Allnet
- Server Maxdata
- Server Matrox
- Server Valcom
- Server Freecom
- Server Revox
- Server G-Technology
- Server Areca
- Server SEH
- Server Ibm
- Server Sonnet
- Server TAIDEN
- Server SIIG
- Server Advantech
- Server Mobotix
- Server Extron
- Server Avocent
- Server Silex
- Server In Win
- Server Sun
- Server Atlona
- Server MvixUSA
- Server Dual Bay
- Server Raidsonic
- Server EMC
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Mr. Signal
- Server Atlantis Land
- Server Lantronix
- Server NETSCOUT
- Server Origin Storage
- Server IMC Networks
Nyeste Server Manualer
21 December 2024
18 December 2024
18 December 2024
15 December 2024
13 December 2024
11 December 2024
9 December 2024
8 December 2024
8 December 2024
8 December 2024