8
Safety
www.bora.com
DANGER!
Risk of electric shock!
Cracks, ssures or fractures in the
glass ceramic panel can damage the
underlying electronics. This can cause
an electrical shock.
If there are any cracks, fissures or
fractures in the glass ceramic,
switch the appliance off
immediately.
Securely disconnect the appliance
from the mains using the LS switch,
fuses, automatic circuit breakers or
contactor.
WARNING!
Risk of burns from hot cooktop!
The cooktop and its exposed areas get
hot during use. Once the cooking zone
is switched o, it takes a little while to
cool down to below 60 °C. Touching
hot surfaces can cause serious burns.
Never touch the cooktop when it is
hot.
Keep children away from the
cooktop when it is hot or ensure
they are supervised at all times.
WARNING!
During or after a power cut, cooktops
may still be hot!
In the event of a power cut, a cooktop
that was previously in operation may
still be hot even though there is no
indication of residual heat.
Do not took the cooktop while it is
still hot.
Keep children away from the hot
cooktop.
WARNING!
Risk of fire from objects on the
cooking surfaces!
The cooktop and its exposed parts are
hot when the cooking zone is switched
on and during the cooling phase.
Objects on the cooktop can heat up
and catch re.
Do not place any items on the
cooktop.
When using recirculation mode, ensure a
sufficient supply of fresh air, e.g. by opening a
window.
Ensure a normal and comfortable room
climate (humidity of 45–60%), e.g. by opening
natural ventilation openings or using domestic
ventilation systems.
After every use in recirculation mode, switch
the cooktop extractor to a low level for about
20 minutes or activate the automatic after-run
function.
Faults and errors
Observe the information in the
Troubleshooting chapter.
In the event of any faults or errors that are
not covered, switch the appliance off.
2.2 Safety instructions Cooktop
operation
Avoid over-cooking.
Pay attention to the residual heat display.
Do not place any hot cookware in the area of
the cooktop display so as not to damage the
underlying electronics.
Make sure that the base of the cookware as
well as the cooking zones are clean and dry.
Always lift (do not drag!) the cookware to
prevent scratching and abrasion on the
surface.
DANGER!
Danger of fire caused by leaving the
cooktop unattended!
Oil or fat in the pot can quickly heat up
and ignite.
Never leave oil or fat to heat up
unattended.
Never extinguish oil and fat fires
with water.
Suffocate the fire, for example by
using a lid.
DANGER!
Risk of explosion caused by
flammable liquids!
Flammable liquids in the vicinity of the
cooktop can explode and cause serious
injury.
Do not spray aerosols in the vicinity
of this appliance while it is in
operation.
Do not place any flammable liquids
in the vicinity of the cooktop.
EN
13
Safety
www.bora.com
2.8 Use as intended
The appliance cannot be used at altitudes above
2,000 m (metres above sea level).
The appliance is solely intended for preparing
food in private households. This appliance is not
intended for:
Outdoor use
Installation in vehicles
Heating rooms
Use in non-stationary installation sites (e.g. on
ships)
Use with an external timer or a separate
remote control system (remote operation)
Any use other than that specified in these
operating and installation instructions or any use
that goes beyond that which is described here is
classed as unintended. BORA does not assume
any liability for damages caused by improper use
or incorrect operation.
All misuse is prohibited!
INFO BORA Holding GmbH, BORA Vertriebs
GmbH & Co KG, BORA APAC Pty Ltd
and BORA ftungstechnik GmbH do
not assume any liability for damage
arising from non-adherence to the
safety and warning information.
EN
19
Device description
www.bora.com
3
4
1
2
Fig. 5.6 Indicator zones
[1] Multi-function display
[2] Fan display
[3] Cooking zone timer indicator (4x)
[4] Warming indicator (4x)
5.2.3 Symbols
Symbols Description Function/meaning
Power button Switching on/off
Pause button Activating/deactivating the
pause function
Cleaning button Activating/deactivating the
cleaning lock
Egg timer button Setting the short-time timer
(egg timer)
Lock button Display lock
Slider Setting values
Plus button Increasing values
Minus button Decreasing values
Fan button Activating/deactivating the
automatic extractor function,
cancelling the after-run
function
Timer button Setting the cooking zone
timer
Warming button Activating/deactivating the
warming function
Tab. 5.2 Meaning of the symbols displayed (icons)
Fig. 5.4 Central touch/slider operating panel
1
2
3
6
4
5
7
810
11
12
13
9
Fig. 5.5 Touch zones/buttons
[1] Switching on/off
[2] Short-time timer (egg timer)
[3] Display lock
[4] Power level setting zone plus
[5] Cooking zone selection (4x)
[6] Touch slider (power level setting zone)
[7] Power level setting zone minus
[8] Warming function
[9] Fan functions
[10] Cooking zone timer
[11] Cleaning lock
[12] Pause function
[13] Select fan/Call up menu
EN
28
Installation
www.bora.com
6.5.2 Pure cut-out dimensions (PURA, PURU)
Pure flush installation (PURA, PURU)
x
764 ±2
740 ±2
519 ±2
≤ R5
≤ R5
≥ 50
(≥ 50)
495 ±2
≥ 600
Fig. 6.12 Cut-out dimensions for ush installation
7 +0,5
12
10 - 40
Fig. 6.13 Rebate dimensions for ush installation
Pure surface mounting (PURA, PURU)
x
740 ±2
≤ R5
≥ 50 (≥ 50)
495 ±2
≥ 600
Fig. 6.14 Cut-out dimensions for surface mounting
10
10 - 40
Fig. 6.15 Overlay dimensions for surface mounting
6.5.1 X Pure cut-out dimensions (PUXA, PUXU)
X Pure flush installation (PUXA, PUXU)
x
834 ±2
810 ±2
519 ±2
≤ R5
≤ R5
50
(≥50)
495 ±2
600
Fig. 6.8 Cut-out dimensions for ush installation
7 +0,5
12
10 - 40
Fig. 6.9 Rebate dimensions for ush installation
X Pure surface mounting (PUXA, PUXU)
x
810 ±2
≤ R5
≥ 50 ≥ 50) (
495 ±2
≥ 600
Fig. 6.10 Cut-out dimensions for surface mounting
10
10 - 40
Fig. 6.11 Overlay dimensions for surface mounting
EN
29
Installation
www.bora.com
Installation dimensions
min.
600
min.
50
199
120
585
(min.
474)
max.
480
60
min.
455
min.
329
min.
100
97
310
Fig. 6.16 Installation dimensions for exhaust air, worktop depth
600 mm
Adjusting the back wall of the unit
Before installation, check the suitability of the
floor unit with regard to the necessary installation
dimensions for the device and the planned duct
system.
If necessary, adjust the position of the back wall
according to the required installation dimensions.
6.6 Installing the appliance in
exhaust mode (PUXA, PURA)
INFO The state and regional laws and regulations must
be observed with regard to the exhaust duct
design. A sufficient air supply must be ensured.
INFO The exhaust air must be directed to the outside by
appropriate exhaust air ducts.
INFO The minimum cross-section of the air ducts must
be 176 cm
2, which equates to a round pipe with
a diameter of 150 mm or the BORA Ecotube duct
system.
INFO As a general rule, with the built-in fan, a length
of duct of up to 6 metres with six 90° bends,
8 metres with four 90° bends or 10 metres with
two 90° bends can be installed.
INFO Not compatible with BORA Universal fans.
INFO Planning instructions for the installation of the
exhaust air ducts are provided in the BORA
ventilation handbook.
6.6.1 Preparing kitchen units
The back wall of the floor unit must be adjusted for the
exhaust air duct.
A minimum clearance of 110 mm between the back
furniture body wall and an adjacent kitchen unit or
room wall must be observed for the air duct.
EN
30
Installation
www.bora.com
Slide the 4 installation clamps [2] until they reach
the stop position in the retaining brackets [1] on the
bottom of the cooktop
Slide the 4 retaining brackets into the fixtures provided
on the bottom of the cooktop.
6.6.3 Inserting the cooktop
54321
Fig. 6.20 Inserting the cooktop
[1] Cooktop
[2] Inlet opening
[3] Air inlet nozzle
[4] Stainless steel grease filter
[5] Worktop cut-out
Before inserting the cooktop, remove the air inlet
nozzle [3] and the stainless steel grease filter [4].
Use the inlet opening [2] as a handle during insertion.
Keep the cooktop [1] straight as you lift it into the
worktop cut-out [5]
Insert the cooktop [1] into the centre of the worktop
cut-out [5].
Precisely align the cooktop.
Information regarding flush installation:
Make sure that the sealing tape of the cooktop is well
sealed all the way round.
Information regarding surface mounting:
Make sure that the sealing tape for the cooktop is flat
against the worktop.
6.6.2 Preparing the cooktop
Attaching the sealing tape
2
1
Fig. 6.17 Sealing tape for surface mounting
1
2
Fig. 6.18 Sealing tape, ush installation
[1] Black, heat-resistant silicone sealant
[2] Sealing tape
With surface mounting, attach the enclosed sealing
tape [2] to the underside of the cooktop before
installing it. Do not leave any gaps.
With flush installation, attach the enclosed sealing tape
[2] to the horizontal cutting edge in the worktop cut-
out, even if you are sealing the cooktop with a silicone
sealing compound [1] or similar.
Fitting the installation clamps
1
2
Fig. 6.19 Inserting the cooktop
[1] Retaining brackets
[2] Installation clamps
INFO 2 installation claps must be fitted to each side of
the cooktop.
EN
31
Installation
www.bora.com
Secure the cooktop to the worktop [1] with the fixing
bracket [3] on the installation clamp [2] .
Tightening torque: max. 2.2 Nm.
6.6.5 Connecting the device to the duct
system
INFO The duct system must be fitted to the device free
of load and with the power supply switched off.
INFO For correct installation, the slide-in units of the
base cabinet must be shortened depending on the
installation situation.
INFO When attaching the seals, ensure that an airtight
seal is created with the connection duct piece
when the seals are compressed.
Use only BORA Ecotube duct parts.
Do not use flexible or fabric hoses.
1
3
2
Fig. 6.24 Connecting the duct system
[1] Seal
[2] Duct part
[3] Exhaust opening
Pull the seal [1] onto the exhaust opening [3] on the
device. The seal [1] will need to be stretched slightly.
Push the duct part to be connected [2] with the
coupling onto the exhaust opening [3] with the seal [1].
Ensure that the seal [1] is not displaced.
Height adjustment plates for flush
installation(optional)
2
Fig. 6.21 Inserting height adjustment plates
[1] Cooktop
[2] Height adjustment plate
1 2
Fig. 6.22 Height adjustment plates
[1] Sealing tape
[2] Optional height adjustment plates
The height adjustment plates are self-adhesive to
prevent slipping during installation.
If necessary, lay the height adjustment plates [2]
underneath.
Place the height adjustment plates next to the sealing
tape [2].
6.6.4 Securing the cooktop
1
2
3
Fig. 6.23 Securing the cooktop in the middle
[1] Cooktop
[2] Installation clamp
[3] Fixing bracket


Produkt Specifikationer

Mærke: Bora
Kategori: Komfur
Model: PUXU

Har du brug for hjælp?

Hvis du har brug for hjælp til Bora PUXU stil et spørgsmål nedenfor, og andre brugere vil svare dig




Komfur Bora Manualer

Bora

Bora PUXU Manual

6 November 2024
Bora

Bora PUXA Manual

6 November 2024

Komfur Manualer

Nyeste Komfur Manualer