Bromic DC200-S Manual

Bromic Komfur DC200-S

Læs nedenfor 📖 manual på dansk for Bromic DC200-S (12 sider) i kategorien Komfur. Denne guide var nyttig for 6 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/12
1 | P a g e R e v 4 . 1
INSTALLATION & OPERATING INSTRUCTIONS
WOK BURNER with FLAME SAFEGUARD
FOR INSTALLATION AND USE INDOORS ONLY
- NOT FOR PORTABLE USE -
AGA APPROVAL NO.: 7092 G
Models for use with Natural Gas:
DC100NG-S Single Burner Wok Cooker
DC200NG-S Double Burner Wok Cooker
Models for use with Universal LP Gas:
DC100-S Single Burner Wok Cooker
DC200-S Double Burner Wok Cooker
FEATURES
Electronic ignition system incorporating piezo-electric elements.
Wok burner suitable for all types of cooking from simmering to stir-frying.
High-energy, high-efficiency burner reduces gas consumption.
Removable control knob incorporating burner ignition.
Large trivet for greater cooking flexibility.
Easy to clean stainless steel top and control panel.
IMPORTANT
Read these instructions carefully before use. Familiarize yourself with the appliance before connecting it to its gas
supply. Keep these instructions for future reference.
THE APPLIANCE MUST BE INSTALLED IN COMPLIANCE WITH THE FOLLOWING:
AS/NZS 5601.1 – Australian Standard for Gas Installations;
Manufacturer’s installation instructions
Local gas fitting regulations
Municipal building codes and
Any other relevant statutory regulation(s). Refer to AS/NZS 5601.1 for piping size details.
GAS PRESSURE REGULATOR DETAILS
FOR NG MODELS
The NG model they must be installed in accordance with AS/NZS 5601.1 by an authorised gas fitter / plumber.
A natural gas regulator Maxitrol RV20LM, AGA Approval No. 3088 with an outlet pressure of 1.0kPa is included with this
appliance.
FOR LP MODELS
Where the LPG models are connected to a permanently fixed reticulated LP Gas supply, they must be installed in
accordance with AS/NZS 5601.1 by an authorised gas fitter / plumber.
Where the LPG models are used in h as an alfresco or balcony situation the purchaser quasi-outdoor/indoor areas suc
(consumer) may use an approved LP Gas regulator and hose assembly connected to a 4.5 or 9.0kg LP Gas cylinder.
The use of 4.5 or 9.0kg LP Gas cylinders inside a building should be avoided.
The appliance must be connected to a certified hose and regulator assembly to ensure safe operation as follows: LP regulator
fitted with a POL type inlet fitting, outlet pressure of 2.75kPa and Certified to AS4621 and an 8mm nominal bore hose
(maximum length 1.5 metres) certified to AS/NZS 1869. Avoid twisting or kinking thee flexible hose.
Inspect the hose regularly. Recommended that the hose be replaced every 5 years.
WARNING: THE CORRECT ASSEMBLY MUST BE USED - DO NOT USE ADAPTORS – If a replacement is required contact Bromic Pty
Ltd.


Produkt Specifikationer

Mærke: Bromic
Kategori: Komfur
Model: DC200-S

Har du brug for hjælp?

Hvis du har brug for hjælp til Bromic DC200-S stil et spørgsmål nedenfor, og andre brugere vil svare dig




Komfur Bromic Manualer

Bromic

Bromic DC100-S Manual

12 September 2024
Bromic

Bromic DC200-S Manual

12 September 2024

Komfur Manualer

Nyeste Komfur Manualer

Silverline

Silverline PEI 3071 Manual

19 September 2024
Smeg

Smeg CIR60X Manual

19 September 2024
Bosch

Bosch PCT915B9TA Manual

19 September 2024
Smeg

Smeg CIR575X Manual

19 September 2024
Smeg

Smeg PV195LCNAU Manual

19 September 2024
Asko

Asko HIH3843FM1 Manual

17 September 2024
Asko

Asko HG8954MGD1 Manual

17 September 2024
Asko

Asko HG8843BGD1 Manual

17 September 2024
Monogram

Monogram ZHU30RDTBB Manual

16 September 2024
Monogram

Monogram ZGU486NDTSS Manual

16 September 2024