CaterChef 508125 Manual


Læs nedenfor 📖 manual på dansk for CaterChef 508125 (2 sider) i kategorien Pastamaskine. Denne guide var nyttig for 34 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
508025-125 ma en 2013.01
P Srofes s iona l up p l ie s
*508.025 / 508.125 ELECTRIC PASTA COOKER - MANUAL
1/2
1 INSTRUCTION FOR THE INSTALLATION
1.1 Technical data
The data plate is near power cable, on the back of the machine and lists all the data needed for connecting
up to the mains.
2 INSTALLATION
The equipment must be positioned using a spirit level and adjusting the legs (screw/unscrew).
The main power switch or power outlet must be near the equipment in an easily accessible position.
We recommend installing the machine under an extractor hood so that vapors can be removed rapidly.
The machine should only be placed near walls, partitions or other kitchen furniture that are made of
ameproof materials.
Fire regulations must be strictly adhered to.
2.1 Legal requirements
Installation must be to the following standards:
- current accident prevention laws;
- CEI installation standards.
2.2 Installation
Installation, setup and maintenance must be carried out by qualifi ed personnel.
All installation work must be done in compliance with current regulations.
The manufacturer will accept no liability in relation to faulty operation due to defective or non compliant
installation.
WARNING! As required by international law, the equipment should only be connected up to the mains if
there is a omnipolar* circuit breaker upstream with a contact opening of at least 3 mm.
2.2.1 Electrical connection
The equipment is supplied with a power cable. If you have to replace this cable, make sure you use a
H07RN-F type and that its cross section is suffi cient for the equipment’s power rating.
To change the cable, pass it through the cable lead and connect the wires to the terminal block, which is
located in the cable lead on single phase machines and inside the equipment on three-phase machines.
Make sure the wires are connected to the terminal block correctly and tightly and then close the cable lead.
The yellow/green wire must be connected to the earth terminal.
2.2.1.1 Unipotential
The equipment must be connected to a unipotential system.
The connection screw is located in the rear of the housing and marked by the sign
WARNING! The manufacturer accepts no liability and will not refund under guarantee any damage caused
through installation that is improper or not compliant with the instructions.
2.3 Set up
The machine must be carefully cleaned (especially the tank, see section 4: Cleaning)