GREAT BRITAIN
For consumer contact, please visit www.clasohlson.co.uk
and click on customer service. INTERNET: www.clasohlson.co.uk
Features
1. Internal measuring jaws
2. External measuring jaws
3. Slider for depth / height measurement
4. Step measuring faces
5. Measuring scale
6. Metric/inches scale
7. Battery cover
8. LCD display
9. Locking screw
10. Thumb roller
11. OFF/ON switch
12. ZERO (reset) switch
13. Inch/mm switch
Operation
1 Before use
The measuring device can only be moved once the locking screw (9)
has been opened.
Wipe off the measuring scale and all measuring surfaces.
Make sure that the display and all function buttons are in working order.
2 Measuring
Loosen the locking screw (9).
Press [OFF ON] (11), then press inch/mm (13) to select measuring units.
Each press of the button switches between inches and mm. The display
comes on automatically when the measuring device is moved even if you
do not press [OFF ON].
Pinch the measuring jaws together to 0 and press [ZERO] (12) to reset
the device to prepare it for use.
Press [OFF ON] (11) to turn off the device after a completed measurement.
External measuring Internal measuring
Differential measuring
Care
Wipe off the entire measuring scale with a soft cloth in order to avoid
faulty readings caused by excess humidity.
Keep the measuring device dry and clean. Do not use solvents for cleaning.
Turn off the measuring device when not in use to save the batteries.
Never measure surfaces that are current carrying.
Never use and engraver to mark measurements the measuring device
may become damaged.
An inaccurate measurement can occur when changing the battery. In this
case remove the battery and wait 30 seconds before replacing it.
Changing the battery
When the display becomes weak the battery needs to be changed. Remove
the battery cover using a small screwdriver and change the battery, with the
plus (+) side facing outwards.
Troubleshooting
Problem Possible Cause Solution
Weak display. Low battery voltage
below 1.45 V.
Replace battery.
Measurement is static
when the measuring
device is moved.
Temporary problem
with the measuring
device.
Remove the battery and
replace it after 30 seconds.
Decreased accuracy
+/- 0.01 mm.
Sensor is dirty. Wipe off the entire measur-
ing scale with a soft cloth.
Nothing on the display. Battery voltage
below 1.4 V.
Replace battery.
Technical specifi cations
Measurement range: 0-150 mm/0-6
Resolution: 0.01mm/0.0005
Accuracy: ± 0.02 mm/0.001 (<100 mm)*
Accuracy: ± 0.03 mm/0.001 (>100 mm)*
Repeatable accuracy: 0.01 mm/0.0005
Measuring system: Linear capacitive measuring system
Display: LCD display
Power supply: SR44, 1.50V button cell battery
Operating temperature: C - 40°C, 41 - 104°F
* Accuracy is decreased markedly if humidity is above 80 % RH
(relative humidity).
40-6925
Digital Vernier Caliper
Depth/height measuring
Step measuring
5
7 381 9
1011
4
2 613 12
25,4 mm
25,4 mm
25,4 mm


Produkt Specifikationer

Mærke: Cocraft
Kategori: Ikke kategoriseret
Model: 40-6925

Har du brug for hjælp?

Hvis du har brug for hjælp til Cocraft 40-6925 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Cocraft Manualer

Cocraft

Cocraft HS2800N Manual

8 September 2024
Cocraft

Cocraft HI 450 Manual

8 September 2024
Cocraft

Cocraft LS4T Manual

8 September 2024
Cocraft

Cocraft HD 550 Manual

19 August 2024
Cocraft

Cocraft HH 2000-E Manual

15 August 2024
Cocraft

Cocraft 40-7818 Manual

14 August 2024
Cocraft

Cocraft HS 50-L Manual

14 August 2024
Cocraft

Cocraft HI 2000 Manual

14 August 2024
Cocraft

Cocraft 40-6925 Manual

13 August 2024
Cocraft

Cocraft LXC MT18 Manual

13 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer