Comark EFG120C Manual
Comark
Voedsel thermometer
EFG120C
Læs nedenfor 📖 manual på dansk for Comark EFG120C (4 sider) i kategorien Voedsel thermometer. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/4
!Kerosene Spirit Filled Glass Thermometer
Safety Data Sheet
Effective date: April 1, 2016 According to 29 CFR 1910:1200 and GHS Rev. 3 Page 1 4 of !
SECTION 1: Identification of the substance/mixture and of the Manufacturer
Chemical Name: - -6) Kerosene (CAS No: 08008 20
Manufacturer Product Name: Kerosene Spirit Filled Glass Thermometer
Recommended uses of the chemical/product: Kerosene dyed with a red aniline dye is the thermometric fluid in a kerosene spirit filled
glass thermometer. The dyed expands or contracts with change in temperature. The thermometer will have approximately 2 cc kerosene
of kerosene.
Manufacturer Details: Emergency Telephone Number:
Miller-Weber of Texas -Chem Tel, Inc. (Contract Number: MIS0003159)
1- - - 6952 Lawndale Street 800 255 3924
Houston, TX 77023
- -713 926 2623 Fax: 713 926 7736- -
SECTION 2: Hazards Identification
The amount of kerosene cc. This section identifies the hazards of the substance, in a single thermometer is approximately two
without regard of amount of kerosene present in the finished product.
Hazard Classification of the chemical -(GHS US Hazard Pictograms):
!
GHS0 GHS0 GHS08 7 9
Signal word (GHS-US): Danger
Hazard statements (GHS US):- H 7 – 22 Combustible liquid.
H – 304 May be fatal if swallowed and enters airways
H – 315 Causes skin irritation
H411 – Toxic to aquatic life with long lasting effects.
Precautionary statements (GHS- US): – P210 Keep away from heat, sparks, open flames, hot surfaces. – No smoking
– P264 Wash skin, hands thoroughly after handling
– P273 Avoid release to the environment
– P280 Wear eye protection, protective clothing, protective gloves, face mask
– P301+P310 IF SWALLOWED: immediately call a POISON CENTER or doctor/physician
P302 - +P352 IF ON SKIN: Wash with plenty of soap and water.
P331 – If swallowed, do NOT induce vomiting
P332+P313 – If skin irritation occurs: Get medical advice/attention
P362 – Take off contaminated clothing and wash before reuse.
P370+P378 – - In case of fire: Use carbon dioxide (CO2), powder, alcohol resistant foam for extinction
P391 – Collect spillage.
5 - P403+P23 Store in a well- ventilated place. Keep cool.
- P405 Store locked up
– P501 Dispose of contents/container to comply with local, state and federal regulations
NFPA/HMIS Ratings (0- - :4) (Non GHS) 2 2 0 Health: , Flammability: , Reactivity: , PPG: See Section 8
SECTION 3: Composition/Information on Ingredients
Name
Product Identifier
%
GHS-US Classification
Kerosine
CAS No. 08008- -6 20
100
Flam. Liq. 4 7 , H22
Skin Irrit. 2, H315
Asp. Tox. 1, H304
Aquatic Chronic 2, H411
See Section 16 for full text of H- phrases
SECTION 4: First aid measures
The first aid measures described in this section are for exposure to kerosene kerosene, regardless of the quantity of the involved in the
exposure. The first aid measures below come from the Safety Data Sheets of our bulk kerosene suppliers.
Description of first aid measures
General: Consult a physician. Show this safety data sheet to the doctor in attendance. Move out of dangerous area.
After inhalation: Move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
After skin contact: Wash off with soap and plenty of water. Consult a physician.
After eye contact: Flush eyes with water as a precaution.
After swallowing (ingestion): Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water.
Consult a physician.
Most important symptoms and effects, both acute and delayed: The most important known symptoms and effects are described in Section 2 and/or in
section 11.
Indication of any immediate medical attention and special treatment needed: No data available.
Produkt Specifikationer
Mærke: | Comark |
Kategori: | Voedsel thermometer |
Model: | EFG120C |
Har du brug for hjælp?
Hvis du har brug for hjælp til Comark EFG120C stil et spørgsmål nedenfor, og andre brugere vil svare dig
Voedsel thermometer Comark Manualer
20 August 2024
20 August 2024
18 August 2024
18 August 2024
18 August 2024
Voedsel thermometer Manualer
- Voedsel thermometer TFA
- Voedsel thermometer Weber
- Voedsel thermometer Laserliner
- Voedsel thermometer Boretti
- Voedsel thermometer Rösle
- Voedsel thermometer Technoline
- Voedsel thermometer Fluke
- Voedsel thermometer Testo
- Voedsel thermometer AcuRite
- Voedsel thermometer Taylor
- Voedsel thermometer Tepro
- Voedsel thermometer Inkbird
- Voedsel thermometer Xavax
- Voedsel thermometer Maverick
- Voedsel thermometer TFA Dostmann
- Voedsel thermometer Ooni
- Voedsel thermometer Grill Eye
- Voedsel thermometer GrillEye
- Voedsel thermometer MEATER
Nyeste Voedsel thermometer Manualer
14 September 2024
9 September 2024
9 September 2024
9 September 2024
9 September 2024
5 September 2024
2 September 2024
2 September 2024
1 September 2024
1 September 2024