What to do in case of fire
1. Donotpanic;staycalm.
2. Leavethebuildingasquicklyaspossible.Touchdoorstofeeliftheyarehot
beforeopeningthem.Useanalternateexitifnecessary.Crawlalongthefloor,
anddonotstoptocollectanything.
3. Callthefiredepartmentfromoutsidethebuilding.
4. Donotgobackinsideaburningbuilding.Waitforthefiredepartmenttoarrive.
Note: Theseguidelineswillassistyouintheeventofafire,
however,toreducethechanceofafirebreakingout,practisefiresafetyprocedures
andpreventhazardoussituations.
Recommended installation site
• Ineverybedroomandchildren’srooms
Inhallwaysandstairways(oneveryfloor)
Basementandattic
• Inroomswithelectricdevices
• Family-andworkroom
What you should consider regarding the installation
Smoke,heatandburningitemswillspreadhorizontallyafterrisingtotheceiling,
soinstallthealarminthemiddleoftheceilingofanordinarystructurehouse
• Ifthealarmforsomereasoncannotbeinstalledinthemiddleoftheceiling,
thedistancebetweenthealarmandthewallcornershouldbeatleast50cm.
Ifthelengthoftheroomorthehallismorethan30foot,youshouldinstall
severalalarmsinthatroomorhall.
• Ifthewallorceilingisslanting,thealarmshouldbeinstalledatleast50cmaway
fromthehighestwallorceilingpointintheroom(Diagram4)
Declaration of Performance
ThissmokedetectorisinharmonisationwithallrequirementsoftheEUDirective
EN14604:2005/AC-2008.TheDeclarationofPerformancecanbefoundonour
websitewww.cordes-rauchmelder.de
Disposal
Wasteelectricalequipmentshouldnotbedisposedofinthehouseholdwaste!
ThedetectorshouldbedisposedofaccordingtoWEEEEUDirective2002/96/EC–
WEEE(WasteElectricalandElectronicEquipment).Ifyouhaveanyquestions,
pleasecontacttheresponsibleauthority.
Disclaimer
CORDESVertriebsgesellschaftmbHshallnotbeliablefordamageofanykind
(includingindividualorconsequentialdamage)resultingfromthefactthatthe
signalofthesmokealarmwasnotactivatedinthepresenceofsmoke.
Furthermore,CORDESVertriebsgesellschaftmbHshallalsonotbeheldliablefor
theconsequencesoffalseordeceptivealarmas:  Costsresulting,forinstance,
fromoperationsofthefirebrigadesorkeyservicesarenotcovered.
CORDES  VertriebsgesellschaftmbH,OpdeSolt42,22391Hamburg,Germany
Thankyouforpurchasingoursmokealarmdevice.Pleasetakeafewminutesto
readtheuser’smanualthoroughlyandfamiliariseyourselfandyourfamilywithits
operation.Keepthemanualforfuturereference.
Product sPecifications:
Power supply DC3VLithiumBattery(built-in)
Electric consumption >8µA(Standby),>50mA(Alarm)
Sound pressure 85dB(A)/3m
Operating status redLEDflashesevery40s
Operating temp. +0°Cto+40°C
Air humidity 10%to90%(non-condensing)
Complies with EN14604:2005/AC:2008
Description
Theunitisaphotoelectricsmokealarmdevice.Withthephotoelectrictechnology,it
ismoresensitivetodetectingslowsmolderfires.
Installation
Activation
Pressthetestbuttonandholditformorethan3secondsuntiltheLEDison,and
releaseitwithinthenext2seconds.Theunitwillgeneratea“beep”,indicatingthat
itisactivatedandgoesintoworkingmode.
Installation
Removethefixingplugfromthebracket(useascrewdriverifnecessary)
(Diagram1).
Installthebracketontheceiling(Diagram2).
Fitthealarmonthebracketandturnthealarmbodyclockwise,untilitmatches
withthebracket.
Insertfixingpluginthegapbetweenthebracketandthebottom(Diagram3).
Pressthetestbuttontotesttheunit
Do not install smoke alarm devices in the following locations
Nearappliancesorareaswherenormalcombustionregularlyoccurs(kitchens,
nearfurnaces,hotwaterheaters).
Inareaswithhighhumidity,suchasbathrooms.
Nearairreturnsorheatingandcoolingsupplyvents.Installatleast3feetaway
fromtheseareas.Theaircouldblowsmokeawayfromthedetector,whichmay
causefailuretoalarm.
Inroomswheretemperaturesmayfallbelow0˚Corriseabove40˚C,orwhereair
humidityishigherthan93˚C.
Inextremelydusty,dirty,orinsect–infestedareas.
Operation
Testing
Youcantestthedetectorbypressingthetestbutton.Testthealarmweeklyto
ensureproperoperation.Thiswillsoundthealarmiftheelectroniccircuitry,horn,
andbatteryareworking.
DO NOT useanopenflametotestyouralarm,youcoulddamagethealarmor
ignitecombustiblematerialsandstartafire.
CAUTION: Duetotheloudness(85decibels)ofthealarm,alwaysstandan
arms-lengthawayfromtheunitwhentesting.
LED indicators
Workingmode:theredLEDflashesonceevery40seconds.Thisindicatesthat
thesmokealarmdeviceisoperatingproperly.
Alarmmode:theredLEDflasheseverysecond.Thisindicatesthatyouareeither
pressingthetestbuttonorthatthedetectorisgoingintoalarm.
Silence(Hush)mode:theredLEDflashesonceevery8seconds,indicatingthe
smokealarmdeviceisinthealarmsilence(Hush)mode.
Alarm silence (silence mode)
Whiletheunitisalarming,youcanpushthetestbuttonandpausethealarm
forapproximately10minutes.TheredLEDwillflashonceevery8seconds.
Thisindicatesthatthesmokealarmdeviceisrunninginthesilencemode.
Thesilencefeatureistobeusedonlywhenaknownalarmcondition,suchas
smokefromcooking,activatesthealarm.
Thesmokealarmdevicewillautomaticallyresetafterapproximately10minutes.
If,afterthisperiod,particlesofcombustionarestillpresent,thealarmwillsound
again.
Thealarmsilencer(silencemode)canberepeateduntiltheairhasbeencleared
oftheconditioncausingthealarm.
CAUTION: Whileextremesmokedevelopmentthesilencemodewillbedeactivated
Maintenance, Cleaning and Battery charge level
Inadditiontoweeklytesting,thealarmrequiresaperiodiccleaningtoremove
dust,dirt,anddebris.
Useavacuumcleanerwiththesoftbrush.Vacuumallsidesandcoversofsmoke
alarmdevice.
Undernormalconditionsthebatterywilllastupto10years
Wheneverthebatteryfallsbelowacertainvoltagelevel,thealarmwillbleepand
theLEDlightwillflashevery40seconds.
Whenthedetectorbleepsthefirsttime,thealarmwillstilloperateatfullcapabi-
lityforatleastanother30days.
WARNING: Thebatteryissealedincoverandnotreplaceable.
Diagram1
Diagram2
Diagram3 Diagram4
Insertfixingplug
housing
srews
plasticdowel
holesinthe
ceilingorwall
Removethefixingplug
GX XX XX 07 89 -C PR -X XX XX
XX
XX
CC-5-CPR-001
EN 14604:2005/AC:2008
09.05.2016


Produkt Specifikationer

Mærke: Cordes
Kategori: Røgdetektor
Model: CC-5/evo10

Har du brug for hjælp?

Hvis du har brug for hjælp til Cordes CC-5/evo10 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Røgdetektor Cordes Manualer

Cordes

Cordes CC-500 Manual

27 December 2024
Cordes

Cordes CC-3000 Manual

27 December 2024
Cordes

Cordes CC-4100 Manual

27 December 2024
Cordes

Cordes CC-5/evo10 Manual

31 August 2024
Cordes

Cordes CC-5 Manual

21 August 2024
Cordes

Cordes GS-506 Manual

21 August 2024
Cordes

Cordes CC-70 Manual

21 August 2024

Røgdetektor Manualer

Nyeste Røgdetektor Manualer

LogiLink

LogiLink SC0016 Manual

29 Januar 2025
FirstAlert

FirstAlert SA700CE Manual

12 Januar 2025
FirstAlert

FirstAlert SA900Si Manual

12 Januar 2025
FireAngel

FireAngel ST-630-DE Manual

30 December 2025
FireAngel

FireAngel W2-Module Manual

30 December 2025
GLORIA

GLORIA R-5 Manual

29 December 2024
Nexa

Nexa KD-134A Manual

27 December 2024
First Alert

First Alert SMI100 Manual

23 December 2024