Residual Current Device
with No-Volt Release Switch
Art.no 18-2032 Model EMP200-UK
32-3492 EMP200S-1
Please read theentire instruction manual before use and save it for
future reference. Wereserve theright for any errors in text or images
and for making any necessary technical changes to this document.
Ifyou should have any questions concerning technical problems
please contact our CustomerServices.
Product description
Theresidual current device’s main function is to protect people and
property if insulation failure should occur in electrical equipment.
Theresidual current device is agood complementary protection to
other safety precautions measures such as fuses and earthing.
This residual current device is anon-latching type which means that
it has ano-volt release switch which has to be reset manually after
apowercut.
For plugging directly into anearthed wall socket.
Trips at 30 mA fault current (mA = one thousandth of anampere).
Equipped with test button and indicator.
Protection class IP44 (32-3492 only).
Safety
Make sure that theelectrical socket that theproduct is plugged
into is easily accessible in case it and theconnected product need
to be quickly disconnected from themains electricity.
Do not connect products of this type to each other.
Do not cover theproduct.
Operation
Residual current device
RCDs operate by measuring thecurrent balance between thelive
and neutral conductor in acircuit. Whenacircuit operates normally,
thesupply and return currents are in balance and sum to zero. Ifthere
is afault in thecircuit (suchas dangerous current leakage through
thebody of aperson to earth), thecurrent will be out of balance and
theRCD will trip and cut off thesupply of current.
Theoperation of theRCD should be checked regularly using thetest
button.
No-volt release switch
Thebuilt-in no-volt release switch prevents theconnected electrical
device (drill, lathe, etc.) from starting again automatically after apower
cut. Theno-volt release switch must be reset by pushing the[ RESET ]
button twice after apower outage before it will allow current to
flowagain.
Use
Theresidual current device is designed to be plugged into anearthed
wall socket.
Plug theRCD into anelectrical socket and press [ RESET ]
twice in order to reset theno-voltage release switch inside before
theRCD’s socket is energized. Asmall orange dot can be seen in
theindication window above the[ RESET ] button when theRCD’s
socket is energized.
Note: Onlyplug theresidual current device into sockets where it can
be inserted with the[ RESET ] button located above thesocket. (Only
applies to theNordic countries)
Testing the RCD
1. Before theresidual current device is used it must be tested by
pushing the[ TEST ] button.
2. Theorange dot in theindication window above the[ RESET ]
button disappears when theRCD trips and cuts off thecurrent to
thesocket.
3. Reset theRCD by pressing the[ RESET ] button twice. Theorange
dot in theindicator window should be visible when theRCD has
been reset and conducts current to thesocket again.
Note: Thetest button only works when theRCD is plugged into alive
electrical socket.
Responsible disposal
This symbol indicates that this product should not
be disposed of with general household waste. This
applies throughout theentire EU. In order to prevent
any harm to theenvironment or health hazards
caused by incorrect waste disposal, theproduct must
be handed in for recycling so that thematerial can be
disposed of in aresponsible manner. When recycling
your product, take it to your local collection facility
or contact theplace of purchase. They will ensure
that theproduct is disposed of in anenvironmentally
sound manner.
Specifications
18-2032 32-3492
Type EMP200-UK EMP200S-1
Protection class ClassA ClassA
Rated voltage 220–240 VAC 220–240 VAC
Rated current 13 A16A
Apparent power
breaking capacity 3120 VA 3680VA
Tripping current 30mA 30mA
Tripping time < 30ms < 30ms
Protection class IP20 IP44
Operating temperature –25 to +40 °C –25 to +40 °C
Current draw 1.2W 1.2W
Certified by TÜV Semko
Note: Alwaysperform afunction test before connecting aload to
theresidual current device’s outlet.
Contact our customer services if thetest of theresidual current device
failed or if you suspect that it does not workproperly.


Produkt Specifikationer

Mærke: Cotech
Kategori: Strømafbryder
Model: EMP200S-1

Har du brug for hjælp?

Hvis du har brug for hjælp til Cotech EMP200S-1 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Strømafbryder Cotech Manualer

Cotech

Cotech EMP200S-1 Manual

27 August 2024

Strømafbryder Manualer

Nyeste Strømafbryder Manualer

Hager

Hager FN366E Manual

9 December 2024
Hager

Hager FN109E Manual

9 December 2024
Hager

Hager FN098E Manual

9 December 2024
Hager

Hager FN100E Manual

9 December 2024
Hager

Hager FN206E Manual

9 December 2024
Hager

Hager FN297E Manual

9 December 2024
Hager

Hager FN437E Manual

9 December 2024
Hager

Hager FN246E Manual

9 December 2024
Hager

Hager EC25100CT Manual

9 December 2024
Hager

Hager HIC463G Manual

9 December 2024