Cotech EMP306SA Manual


Læs nedenfor 📖 manual på dansk for Cotech EMP306SA (4 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 13 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
GREAT BRITAIN
For consumer contact, please visit www.clasohlson.co.uk and click on customer service.
English Ver. 200907
Energy Saving Extension Lead
Art.no. 18-2124 Model EMP306SA-UK
36-3388 EMP306SA
Please read the entire instruction manual before using and
save it for future use. We apologise for any text or photo errors
and any changes of technical data. If you have any questions
concerning technical problems please contact our Customer
Service Department (see address on reverse).
Product description
Saves energy and reduces the risk of fires by shutting off all
connected devices. Connect your computer to the master out-
let and your screen, printer, scanner, etc. to the slave outlets.
Turning on your computer also turns on all devices connected
to the slave outlets.
- The threshold value of the master outlet can be
adjusted, 8-80 W.
- Safety shutters.
- Equipped with 1 master outlet and 5 earthed slave outlets.
- All outlets have built-in surge protection.
- Contains 4 varistors, 2 fuses, and 1 gas discharge tube.
- Two indicator lamps:
Blue - lights when the slave outlets are activated.
Green - lights when surge protection is functioning.
- 240 V / 13 A, max. 3120 W.
Safety
- The product is intended for indoor use only.
- Connected devices must be designed for 240 V AC, 50 Hz.
- If the green LED is unlit the surge protection has been trig-
gered and no longer offers protection. The extension leads
energy saving function is operative and the lead can be
used as normal but without the benefit of surge protection.
- If the blue LED does not come on, make sure that the
connected devices are turned on and that the rated power
is not less than 8 W.
- The device which is connected to the master outlet
should have a power consumption of between 8 and
80 W (or the lead’s automatic control will not work).
- The surge protector will not protect the device NOTE:
from excessively high transient voltage spikes or direct
lightning strikes.
Operation
Devices connected to the slave outlets will turn on when
the master outlet exceeds the threshold set by the adjusting
screw, and turn off when the load falls below the set value.
- Turning OFF OFF your computer also turns all devices
connected to the slave outlets.
- Turning your computer also turns all devices ON ON
connected to the slave outlets.
N.B.
- If you switch the device which is connected to the master
outlet to a device which does not have the same power
rating, you must readjust the threshold setting again accor-
dingly. If both devices have the same power consumption
no adjustment is needed.
Troubleshooting
The green “Protect” – indictor light is not lit:
1. The surge protector is not working. The function may have
been disabled by lightning or overvoltage.
The blue “Slave” – indicator light is not lit after adjusting
the threshold setting. Check:
1. That the device connected to the master outlet is turned on.
2. That the connected device does not have a power con-
sumption of less than 8 W (in these cases the automatic
switch will not work).
Disposal
Follow local ordinances when disposing of this product.
If you are unsure of how to dispose of this product, please
contact your municipality.
Specifications
Rated voltage 240 V AC, 50 Hz, 13 A
Max load Slave Max. 3120 W
Max load Master 550 W
Threshold value min / max 8 W 80 / W (master outlet)
Protection Class II
Uoc P-N = 2.5 kV
P/N-E = 5.0 kV
Up P-N = 2.0 kV
P/N-E = 2.5 kV
Uc 240 V AC
1. First make sure the devices you are connecting are
turned off.
2. Connect the plug to a wall socket.
3. Connect the device (e.g. your computer) which you want
to use to turn you other devices on/off to the master
outlet. The green LED should light and indicate that the
surge protection is functioning.
4. Turn on the device connected to the master outlet.
5. Begin by first turning the adjusting screw anticlockwise
to max. Then slowly turn the adjusting screw clockwise
to adjust the threshold for the on/off feature. Stop when
the blue LED lights. The LED indicates that the setting
is correct.
6. Connect the rest of the devices (monitor, printer, etc.)
to the slave outlets.
7. Switch on the connected device/s.
Adjusting screw
Green LED
Blue LED


Produkt Specifikationer

Mærke: Cotech
Kategori: Ikke kategoriseret
Model: EMP306SA

Har du brug for hjælp?

Hvis du har brug for hjælp til Cotech EMP306SA stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Cotech Manualer

Cotech

Cotech HT7715 Manual

18 September 2024
Cotech

Cotech K-CPL-LS4W-IR-S3 Manual

16 September 2024
Cotech

Cotech J1x-JF2-210/20 Manual

14 September 2024
Cotech

Cotech TD9511-3 Manual

12 September 2024
Cotech

Cotech S1J-AJ8-10 Manual

31 August 2024
Cotech

Cotech J5218D Manual

27 August 2024
Cotech

Cotech 50053 Manual

27 August 2024
Cotech

Cotech 51097X23 Manual

27 August 2024
Cotech

Cotech 36-6286 Manual

27 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024