INET-IOEX-IRCOM
inNET EX® Control Module
Installation Guide
Description
The INET-IOEX-IRCOM provides an IR and RS-232
control interface for video displays, AV components,
small appliances, and other equipment. It includes two
discrete IR ports and one bidirectional RS-232 port. It
communicates with a Crestron® control system via the
inNET EX® wireless network, enabling control and
monitoring of the remote equipment without having to
run wires through walls and ceilings.
Installation
The INET-IOEX-IRCOM can be mounted onto any at
surface using three screws (not included). For best
results, position the device to avoid interference from
nearby RF sources, obstructions, and metal surfaces.
Additional Resources
Visit the product page on the
Crestron website
(www.crestron.com) or scan the QR
code to the right for additional
information and the latest rmware
updates.
CAUTION: Observe the + and - markings on the
power pack leads. Connect the + to the 5 terminal
and the - to the G terminal on the INET-IOEX-IRCOM.
NOTE: The INET-IOEX-IRCOM can also be powered
via USB. For example, refer to the TTL-232R-5V-WE
at www.mouser.com.
Hardware Hookup
Make the necessary connections as called out in the
following illustration.
When making connections to the INET-IOEX-IRCOM,
use Crestron power supplies for Crestron equipment.
G/TX/RX:
To Any
RS-232 Device
S/G (1 - 2):
To IR Devices
PWR:
From DC
Power Pack
Wireless Communications
The INET-IOEX-IRCOM connects to the Crestron
network via the inNET EX communications protocol.
Use the procedures outlined below to join or leave an
inNET EX network and to verify communications
between the device and the control system.
Joining an inNET EX Network
Before the INET-IOEX-IRCOM can be used, it must rst
join an inNET EX network by being acquired by an
inNET EX gateway.
NOTE: A device can be acquired by only one
gateway.
1. Put the inNET EX gateway into Acquire mode
from the unit itself or from Crestron Toolbox™, as
described in its manual at
www.crestron.com/manuals.
NOTE: In an environment where multiple
gateways are installed, only one gateway should
be in Acquire mode at any time.
2. Place the device into Acquire mode.
a. Tap the button three times, and then SETUP
press and hold it down
(tap-tap-tap-press+hold) until the LED on the
device blinks once (this can take up to 10
seconds).
b. Release the button to start the acquire process.
The LED blinks slowly to show that the device
is actively scanning the inNET EX network.
The top LED turns on for 5 seconds to show
that the device has been successfully
acquired by the infiNET EX network.
The LED blinks fast to indicate that the
device was not successfully acquired by the
infiNET EX network. Tap the button SETUP
to acknowledge failure to acquire the
infiNET EX network. Ensure the gateway is
in Acquire mode and within range before
attempting the acquire process again.
3. Once all devices have been acquired, take the
gateway out of Acquire mode. Refer to the
gateway’s operations guide for details.
Leaving an inNET EX Network
To leave an inNET EX network, put the
INET-IOEX-IRCOM into Acquire mode, as described in
“Joining an inNET EX Network” above, when no
gateway is in Acquire mode.