CyberPower CP685AVR Manual


Læs nedenfor 📖 manual på dansk for CyberPower CP685AVR (2 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne guide var nyttig for 24 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
LE825G / CP685AVR-G / CP825AVR-G
User’s Manual
K01-0000064-01
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit.
Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive
contaminants. (Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. There are no user serviceable parts
inside except for battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
grounded. If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer
component.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch cir cuit over current protection in
accordance with the National Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
applications. use in any circumstance that would affect, operation, safety of any life support equipment or with any medical DO NOT
applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation
from the aquarium can cause the unit to short out.
INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(1) UPS unit; (2) User ’s manual; (3) USB device cable; (4) PowerPanel® Personal Edition software CD or Free download card
WHAT IS AVR?
The LE825G/CP685AVR-G/CP825AVR-G provide complete power protection
from utility power that is not always consistent. The
LE825G/CP685AVR-G/CP825AVR-G feature 1030 Joules/890 Joules/1030
Joules of surge protection, and provide long lasting battery backup during
power outages. The LE825G/CP685AVR-G/CP825AVR-G ensure consistent
power to your computer system and include software that will automatically
save your open files and shutdown your electronic equipment during a utility
power loss.
AUTOMATIC VOLTAGE REGULATOR
The LE825G/CP685AVR-G/CP825AVR-G stabilize utility power voltage levels
that can be inconsistent. The incoming utility power may be damaging to
important data files and hardware, but with Automatic Voltage Regulation, the
computer will not experience damaging voltage levels. An Automatic Voltage
Regulator automatically increases low or decreases high voltage to a
consistent, computer safe 110v/120v. The unit’s powerful battery will provide power only if the incoming voltage drops below 90v or increases
above 140v.
SYSTEM FUNCTIONAL BLOCK DIAGRAM
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity (685VA/390W for CP685AVR-G,
825VA/450W for LE825G/CP825AVR-G). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the
UPS unit to shut down or the circuit breaker to trip.
2. There are many factors that can affect the amount of power that your electronic equipment will require. It is suggested that the load you will
be placing on the outlet not exceed 80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the
battery for at least 8 hours is recommended to ensure that the battery’s maximum
charge capacity is achieved. A loss of charge may occur during shipping and
storage. To recharge the battery, simply leave the unit plugged into an AC outlet.
2. With the UPS unit off and unplugged, connect your computer, monitor, and any other
peripherals requiring battery backup into the battery power supplied outlets. Plug
your other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets. DO NOT plug a laser printer, paper
shredder, copier, space heater, vacuum cleaner, sump pump or other large electrical device into battery and surge protected outlets.
The power demands of these devices will overload and possibly damage the unit.
3. To protect a network connection from surges, connect a network cable into the IN jack of the UPS. Then connect
a network cable from the OUT jack on the UPS to the network device.
4. Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
conditioner, refrigerator, copier, etc…). The warranty prohibits the use of extension cords, outlet strips, and surge strips in conjunction with
the UPS unit.
5. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will “beep”.
6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at
least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. To store your UPS for an extended period of time, cover it and store with the battery fully charged. While in storage recharge the battery
every three months to ensure battery life.
BASIC OPERATION
DESCRIPTION
Battery and Surge Protected Outlets
The unit has four battery powered/surge suppression outlets for connected
equipment to ensure temporary uninterrupted operation of your equipment
during a power failure. ( DO NOT plug a laser printer, paper shredder,
copier, space heater, vacuum cleaner, sump pump or other large
electrical device into battery and surge protected outlets. The power
demands of these devices will overload and possibly damage the unit.)
Full-Time Surge Protection Outlets
The unit has four surge suppression outlets which are always ON.
Power Switch
Press the power button to turn the UPS ON or OFF.
Power On Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
Electrical Wiring Fault Indicator
This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If
this is illuminated, it is recommended to disconnect all electrical equipment from the outlet and have an electrician verify the outlet is
properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet.
Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line, network or Ethernet connection (RJ11/RJ45).
Circuit Breaker
Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.
USB Port and DB-9 Contact Closure Port to PC
The ports allow connection and communication between the USB or DB-9 port on the computer and the UPS unit. The UPS
communicates its status to the PowerPanel
® Personal Edition software.
Note: Only one of the ports, USB or DB-9, can be used to communicate with your computer at one time.
Outlets Designed for AC Adapters
The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without overlapping or blocking adjacent
outlets.
Coax/Cable/DSS Surge Protection
The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver.
REPLACING THE BATTERY
Replacement of batteries located in an OPERATOR ACCESS AREA.
1. When replacing batteries, replace with the same number of the following battery: RB1280 for CP685AVR-G; RB1280A for
LE825G/CP825AVR-G.
2. CAUTION! Risk of Energy Hazard, 12V, maximum 8 (CP685AVR-G) or 9 (LE825G/CP825AVR-G) Ampere-hour battery. Before replacing
batteries, remove conductive jewelry such as chains, wrist watches, and rings.
3. Do not dispose of batteries in a fire. The batteries may explode; CAUTION!
4. Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. CAUTION!
CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING
TO LOCAL REGULATIONS.
TO REPLACE T HE BATTERY
1. Turn off and unplug all connected equipment.
2. Unplug it from the AC power source.
3. Turn the UPS upside down.
4. Remove the 1 retaining screw.
5. Slide the battery compartment cover completely off of the unit.
6. Remove the battery from the compartment.
7. Disconnect the battery wires from the battery.
8. Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (-) terminal of the battery.
9. Put the battery back into the compartment.
10. Slide back the battery compartment cover and tighten the retaining screw.
11. Charge the unit for 4 – 8 hours to fully charge the battery.
REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sells lead-acid batteries
collects used batteries for recycling, as required by local regulations.
TROUBLE SHOOTING
Problem Possible Cause Solution
Full-time surge protection outlets
stop providing power to
equipment. Circuit breaker
button is projecting from the side
of the unit.
Circuit breaker has been tripped due
to an overload.
Turn the UPS off and unplug at least one piece of equipment.
Wait 10 seconds, reset the circuit breaker by pressing the
button, and then turn the UPS on.
The UPS does not perform
expected runtime.
Battery not fully charged. Recharge the battery by leaving the UPS plugged in.
Battery is worn out. Contact CyberPower Systems about replacement batteries at
tech@cpsww.com.
The UPS will not turn on.
The on/off switch is designed to
prevent damage by rapidly turning it
off and on.
Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The unit is not connected to an AC
outlet. The unit must be connected to a 110/120v 60Hz outlet.
The battery is worn out. Contact CyberPower Systems about replacement batteries at
tech@cpsww.com.
Mechanical problem. Contact CyberPower Systems at tech@cpsww.com.
PowerPanel® Personal Edition is
inactive (all icons are gray).
The USB / serial cable is not
connected.
Connect the USB / serial cable to the UPS unit and an open
USB / serial port on the back of the computer. You must use
the cable that came with the unit.
The USB / serial cable is connected
to a bad USB port. Check for a different USB port and plug the cable in.
The unit is not providing battery
power.
Shutdown your computer and turn the UPS off. Wait 10
seconds and turn the UPS back on. This should reset the unit.
The serial cable is not the cable that
was included with the UPS unit.
If you are using a serial cable you must use a CyberPower serial
cable. If you need this cable please contact technical support.
tech@cpsww.com.
Additional troubleshooting information can be found at “Support” at
www.CPSww.com
EMI Filter
Surge
Suppressor
AVR
Charger
AC/DC
Battery
Inverter
Input Output
Normal Mode
Battery Mode


Produkt Specifikationer

Mærke: CyberPower
Kategori: Uafbrydelig strømforsyning (UPS)
Model: CP685AVR
Batteriteknologi: Blybatterier (VRLA)
Formfaktor: Kompakt
Responstid: 4 ms
Relativ luftfugtighed ved drift (H-H): 0 - 95 %
Ethernet LAN-porte (RJ-45): 1
Antal USB 2.0-porte: 1
Driftstemperatur (T-T): 32 - 95 °F
Dimensioner (BxDxH): 279.4 x 89 x 165 mm
Udgangseffekt: 390 W
Certificering: UL1778, cUL, FCC DOC Class B
Opladningstid for batteri: 8 t
Lydalarmer: Ja
Input forbindertype: NEMA 5-15P
Antal serielle porte: 1
Dimensioner (BxDxH) (efter britisk standard): 11 x 3.5 x 6.5 "
Modem-porte (RJ-11): 1
Overspænding energivurdering: 890 J
Output strømkapacitet (VA): 0.685 kVA
UPS topologi: Interaktivt indgangsstik
Typisk backup tid ved halv styrke: 10 min.
Typisk backup tid ved fuld styrke: 2 min.
Udskiftningsbatteri: BB - BP8-12

Har du brug for hjælp?

Hvis du har brug for hjælp til CyberPower CP685AVR stil et spørgsmål nedenfor, og andre brugere vil svare dig




Uafbrydelig strømforsyning (UPS) CyberPower Manualer

Uafbrydelig strømforsyning (UPS) Manualer

Nyeste Uafbrydelig strømforsyning (UPS) Manualer

LevelOne

LevelOne UPS-2103 Manual

22 Oktober 2024
LevelOne

LevelOne UPS-2102 Manual

22 Oktober 2024
Aiptek

Aiptek VI 850 LCD Manual

21 Oktober 2024
APC

APC Back-UPS BN4001 Manual

12 Oktober 2024
APC

APC RBC9 Manual

24 September 2024
APC

APC RBC22 Manual

24 September 2024
APC

APC AP9626 Manual

24 September 2024