CyberPower CPS3000EILCD Manual
CyberPower
Solpanel
CPS3000EILCD
Læs nedenfor 📖 manual på dansk for CyberPower CPS3000EILCD (2 sider) i kategorien Solpanel. Denne guide var nyttig for 18 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
CPS 00EILCD 30
User’s Manual
IMPORTANT SAFETY INFORMATION
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack,
install, or operate the INVERTER.
Insure the wall outlet and INVERTER are located near the equipment being attached for proper
accessibility.
To reduce risk of damage and injury, please use batteries th good quality. wi
Provide adequate ventilation for the battery compartment. The battery enclosure should be designed to
prevent accumulation and concentration of hydrogen gas at the top of the compartment.
DO NOT expose the INVERTER to rain, snow or liquids of any type. T INVERTER is designed for he
indoor use only.
DO NOT obstruct the ventilation openings.
DO NOT connect neutral of the power distribution box on the wall to:
(a) The OUTPUT neutral of INVERTER .
or (b) The INPUT neutral of equipment.
Otherwise the reversed polarity will damage the INVERTER and the connected equipmen t.
CAUTION! Risk of electric shock, do not remove cover. No user serviceable parts inside.
The battery can energize hazardous live parts inside even when the AC input power is disconnected.
To avoid electrical shock, turn o the INVERTER and unplug it from the AC power source before
servicing the battery. Servicing the battery can only be performed by trained personnel.
To avoid electrical shock, install the metal cover of the terminal block after the AC input and
output is connected.
INSTALLING YOUR INVERTER SYSTEM
UNPACKING
Inspect the unit upon receipt. The box should contain the following:
INVERTER Unit 1; Power Cord 1; User Manual 1
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Insure that the equipment plugged into the outlet does not exceed the INVERTER AC unit’s rated
capacity ( 00VA/1 0W for CPS ILCD If rated unit capacities are exceeded, an overload 30 80 3000E ).
condition may occur and cause the INVERTER unit to shut down or the circuit breaker trip.
2. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert
Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only
calculates the maximum amount of VA that the equipment can use, not what is typically used by the
equipment at any one time. Users should expect usage requirements to be approximately 60% of
below value.
TO ESTIMATE POWER REQUIREMENTS
1. 220 V x Amps (A) = VA
2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual
requirements There are many factors that can aect the amount of power that your computer system .
will require. The total load that you will be placing on the battery-powered outlets should not exceed
80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
Before installation, please read and understand the following instructions:
1. Placement
The INVERTER must be installed in a protected environment away from h - emitting appliances eat
such as a radiator or heat register. Do not install this product where excessive moisture is present.
2. Ventilation
The location should provide adequate air ow around the INVERTER with 10 CM minimum
clearance on all sides for proper ventilation.
3. Connect the Battery
Connect the external battery with the DC cables
from the back of the INVERTER. Follow battery
polarity guide located near battery cables as
below.
+“ ” Red cable for battery positive polarity;
“ ”- Black cable for battery negative polarity.
4. Connect to AC and Charge the Battery
Connect the INVERTER to a wall outlet using extension cords To be connected well, the ends of .
the cords which connect the inverter should be compressed into the attached pin terminals. The
wire diameter should not be less than 1.3mm2.
. Charging the battery for at least 8 hours is recommended to insure that the battery is fully charged.
To recharge the battery, simply leave the unit plugged into a wall outlet. To maintain optimal battery
charge, leave the INVERTER connect an AC outlet at all times.
This INVERTER can be charged even when INVERTER is not turn ed on.
5. Connect the Load
Connect the equipment to the INVERTER outlet using extension cords To be connected well, the .
ends of the cords which connect the inverter should be compressed into the attached pin terminals.
The wire diameter should not be less than 1.3mm
2.. Please make sure that the total loads of your
equipments are less than the maximum total power load of the INVERTER. Screw the terminal
block cover onto the inverter nally.
BASIC OPERATION
FRONT PANEL DESCRIPTION
1. LCD Module Display.
High resolution and intelligent LCD display shows all the INVERTER information with icons and
messages. For more information please check the “Definitions for Illuminated LCD Indicators”
section.
2. Power Switch
Press the power switch to turn the INVERTER ON or OFF.
3. LCD Function Selected Switch
The switch can be used to select the LCD display contents including input/output voltage and load
percentage, etc.
REAR PANEL DESCRIPTION
4. DC Input Cable (Black)
Connect to battery negative polarity.
5. DC Input Cable (Red)
Connect to battery positive polarity.
6. Input Circuit Breaker
The circuit breaker provides optimal overload protection.
Produkt Specifikationer
Mærke: | CyberPower |
Kategori: | Solpanel |
Model: | CPS3000EILCD |
Har du brug for hjælp?
Hvis du har brug for hjælp til CyberPower CPS3000EILCD stil et spørgsmål nedenfor, og andre brugere vil svare dig
Solpanel CyberPower Manualer
24 September 2024
24 September 2024
23 September 2024
23 September 2024
21 September 2024
7 September 2024
7 September 2024
7 September 2024
6 September 2024
6 September 2024
Solpanel Manualer
- Solpanel EasyMaxx
- Solpanel Aukey
- Solpanel LG
- Solpanel Victron Energy
- Solpanel Sharp
- Solpanel Technaxx
- Solpanel Livoo
- Solpanel Furrion
- Solpanel Dometic
- Solpanel Mestic
- Solpanel Vivanco
- Solpanel Osram
- Solpanel KKT Kolbe
- Solpanel BenQ
- Solpanel Anker
- Solpanel Tesla
- Solpanel Imou
- Solpanel Polaroid
- Solpanel Velleman
- Solpanel Perel
- Solpanel Projecta
- Solpanel Reolink
- Solpanel Xtorm
- Solpanel Viessmann
- Solpanel EcoFlow
- Solpanel Sunrise
- Solpanel SereneLife
- Solpanel BLUEPALM
- Solpanel V-TAC
- Solpanel Enphase
- Solpanel Growatt
- Solpanel Steren
- Solpanel Fantini Cosmi
- Solpanel Tru Components
- Solpanel Paulmann
- Solpanel SolarEdge
- Solpanel ECTIVE
- Solpanel APsystems
- Solpanel FOX ESS
- Solpanel Goal Zero
- Solpanel BlauHoff
- Solpanel Deye
- Solpanel Tycon Systems
- Solpanel Fimer
- Solpanel Renogy
- Solpanel Sunware
- Solpanel Longi
- Solpanel Yingli Solar
- Solpanel SunPower
- Solpanel Trina Solar
Nyeste Solpanel Manualer
15 December 2024
14 December 2024
4 December 2024
4 December 2024
3 December 2024
26 November 2024
18 November 2024
15 November 2024
14 November 2024
14 November 2024