CyberPower DTC50U12V Manual


Læs nedenfor 📖 manual på dansk for CyberPower DTC50U12V (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 6 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Users Manual for
CyberShield
DTC50U12V3
CyberShield UPSs are designed to provide a local power solution for
cable telephony, wireless local loop (WLL), and fiber to the home
(FTTH) broadband equipment.
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
INSTALLATION
OVERVIEW
DESKTOP USE:
1.) Open the battery door at the back of the DTC50U12V3 and connect the battery wires.
2.) Plug AC power cable into wall outlet.
3.) Connect the communication cable and simply place the DTC50U12V3 unit on or
underneath desk to begin backing up the optical home network.
BATTE REPLACEMENTRY
As long as utility power is on, you may leave the UPS and connected equipment on while replacing a new
battery. (For service personnel reference only)
COLD START
Step 1:
Connect the AC cable to the wall outlet.
Step 2:
Connect the communication cable between the DTC50U12V3
and the ONT device.
Step 1:
a. Slide off the battery
cover at the back of the
DTC50U12V3 unit.
Step 2:
a. Remove the battery from
the enclosure.
b. Disconnect both battery
cable connectors.
Step 3:
a. Install the new battery by connecting
the red lead to the positive terminal
and the black lead to the negative
terminal.
b. Slide the battery back into the
compartment.
c. Replace battery cover to resume
normal operation.
Step 3:
Install the cable retainer to secure the
commnication cable.
Step 4:
Use the enclosed wall mount template to locate screws on the
wall. Hang the DTC50U12V3 on the screws which are located
on the wall.
The cold start feature is to supply power to the UPS and connected equipment when the UPS
shuts down and no utility power is available. Before using the cold start feature, please make sure
that the battery is properly charged. To turn on the cold start feature, please press and hold the
cold start button until 4 LED indicators light up.
This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack, install or operate this device.
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is
disconnected.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area, free of conductive contaminants. (Please see specifications for
acceptable temperature and humidity range.)
CAUTION! To reduce the risk of electric shock, do not remove the cover. No user serviceable
parts inside include battery. Please contact our company or our dealer directly.
CAUTION! When replacing batteries, the replacement should have the same rating as follows,
Listed/Certified Valve Regulated Lead Acid Battery, 12V, max. 9Ah.
CAUTION! Ri nerg Ha ard ba ersk f Eo y z , tt y. B tt , cef c ore repla ing ba eries remove onduc jewelrtive y
s a th s t uch s c s, st tc s, hain wri wa he and rings and use ools wi t in ula ed handle Highs.
energ hrough condu ive ma erials ould cau e severe burny t ct t c s s.
CAUTION! Do not dispose of batteries in a fire. The battery may explode if improperly disposed.
Recycle batteries in accordance with local regulations.
CAUTION!
CAUTION!
CAUTION!
Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It
may be toxic.
The UPS battery is charged when it is connected to utility power. The battery is fully
charged during the first of normal operation. Do not expect full battery run 24 hours
capability during this initial charge period.
7
6
5
4
ALARM SILENCE
The audible alarm will be enabled when the unit is operating from battery or battery power is low.
Press the Alarm Silence button for 0.5 seconds, the unit will beep once confirming that audible
alarms have been temporary disabled for 24 hours. Press this button one more time for 0.5 seconds
to enable audible alarms again. The unit will beep twice confirming that audible alarms have been
enable. Or press and hold the Alarm Silence button for 15 seconds the units will beep once confirm
-
ing that audible alarms have been disabled permanently. To restore the audible alarm, press and
hold the Alarm Silence button for 15 seconds and the unit will beep twice confirming that audible
alarms have been enabled.
WALL MOUNT USE:
1
2
3
8LED Indicator
Alarm Silence Button
Cold Start Button
Cable Retainer Installation Point
Communication Cable Connector
AC Power Cable Connector
Battery Cover
1
2
3
4
5
6
7
8
External Battery Connector
LED INDICATOR
DC
BATTERY
SYSTEM
S TUSTA
MUTE
Green
Green
Orange
Red
Indicates normal mode of operation.
Indicates the battery is supplying the power. At 45% battery capacity,
the LED will flash and then alarm will beep 4 times per minute.
Press and hold the button “Alarm Silence” for 0.5 seconds to silence
the audible alarm for 24 hours, and the LED will flash.
Battery replacement required. Alarm will beep once every 15 minutes.
The LED also illuminates when battery is absent.
The recommended capacity of an external battery is less than 100Ah. External batteries
should be fully charged before used.
Indicator Color Condition
Number Description


Produkt Specifikationer

Mærke: CyberPower
Kategori: Ikke kategoriseret
Model: DTC50U12V

Har du brug for hjælp?

Hvis du har brug for hjælp til CyberPower DTC50U12V stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret CyberPower Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024