CyberPower Intelligent LCD BRG850AVRLCD Manual

CyberPower Uafbrydelig strømforsyning (UPS) Intelligent LCD BRG850AVRLCD

Læs nedenfor 📖 manual på dansk for CyberPower Intelligent LCD BRG850AVRLCD (2 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne guide var nyttig for 17 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
BRG850AVR LCD
BRG1000AVR LCD
User Manual s
Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at www.cpsww.com/registration.
Registration certies your product's warranty, conrms your ownership in the event of a product loss or theft and entitles you to free technica
support. Register your product now to receive the benets of CyberPower ownership.
(SAVE THESE INSTRUCTIONS)
This Manual Contains Important Instructions that should be followed during Installation and Maintenance of the UPS and batteries.
CAUTION! To prevent the risk of re or electric shock, install in a temperature and humidity controlled indoor area free of conductive
contaminants. (Please see specications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before
servicing the batteries. There are no user serviceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
grounded. If you need to de-energize this equipment, turn o and unplug the unit.
CAUTION! To avoid electric shock, turn o the unit and unplug it from the AC power source before servicing the battery.
CAUTION! Not for use in a computer room as dened in the Standard for the Protection of Electronic Computer/Data Processing Equipment,
ANSI/NFPA 75.
CAUTION! To reduce the risk of re, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in
accordance with the National Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
applications. use in any circumstance that would aect the operation safety of life support equipment, medical applications, or DO NOT and
patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of re or electric shock, do not use with or near an aquarium. Condensation
from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of re or electric shock, do not use the unit on any transportation
such as airplanes or ships. The eect of shock or vibration caused ing transit and the damp environment can cause the unit to short out. dur
INTRODUCTION
Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and
performance during the lifetime of the product.
UNPACKING
Inspect the UPS upon receipt The box should contain the following: .
(a) UPS (b) User’s manual (c USB A+B type cable Function Setup Guide ) (d)
*PowerPanel® Personal Edition software is available on our website. Please visit www.cpsww.com and go to the Software Section for
free download.
OVERVIEW
T BRG850AVRLCD/BRG1000AVRLCD provides complete power protection from utility power that is not he
always consistent. The BRG850AVRLCD/BRG1000AVRLCD features 1080 Joules of surge protection. Both
units ovide long las ting battery backup during power outages with maintenance free batteries. The pr
BRG850AVRLCD/BRG1000AVRLCD ensures consistent power to your computer system and includes software
that will automatically save your open les and shutdown your computer system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The BRG850AVRLCD/BRG1000AVRLCD stabilizes inconsistent utility power voltage to nominal levels that are safe for equipment. Inconsistent
incoming utility power may be damaging to important data les and hardware, but with Automatic Voltage Regulation (AVR), damaging voltage
levels are corrected to safe levels. AVR automatically increases low utility power or decreases high utility power to a consistent and safe
110/120 volts.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. 850 Ensure that the equipment plugged into the y (outlet does not exceed the UPS’s rated capacit VA/510W for BRG850AVRLCD,
1000VA/600W for BRG1000AVRLCD). If the rated capacities of the units are exceeded, an overload condition may occur and cause the
UPS to shut down or the circuit breaker to trip.
2. There are many factors that can aect the amount of power that your computer system will require. It is suggested that the load placed on
the battery outlets not exceed 80% of the unit s capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the
battery s maximum charge capacity, it is recommended that you charge the battery for at least 8 hours.
Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the
battery will automatically charge whether the UPS is turned on or o.
2. Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment.
The rst time you turn the UPS , you will need to have it connected to AC power or it will not power up. on
3. With the UPS unit turned o and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup into the
battery power supplied outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large
electrical devices into the Battery and Surge Protected Outlets The power demands of these devices may overload and damage “ ”.
the UPS.
4. To protect a fax, phone or modem, connect a telephone cable or network cable from the wall jack outlet to the IN
jack of the UPS. Connect a telephone cable or network cable from the OUT jack of the UPS to a fax machine,
telephone, modem, or network devices.
5. ed Plug the UPS into a 2 pole, 3 wire ground receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
conditioner, The warranty prohibits the use of extension cords, outlet strips, and surge strips. copier, etc…).
6. Press the power switch to turn the unit on. The Power On indicator light will illumin . ate and the unit will “beep”
If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS o and unplug at
least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three
months to e ure battery life. ns
9. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
DESCRIPTION
1 Power Switch
Used as the master on/o switch for equipment connected to the battery power supplied outle . ts
2 Power On Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
3 LCD module display
The LCD display shows all the UPS information using icons and messages. For more information please review the Denitions for
Illuminated LCD Indicators section below.
4 Down/Display Button
The button can be used to select the LCD display contents including Input Voltage, Output Voltage, and Estimated Run Time. Short press
the button to scroll down the function menu. Pressing the button for 2 seconds will keep the LCD display always on or turn the LCD display
o while in AC/Utility power mode. For more information about the Down/Display Button, please refer to the Function Setup Guide.
5 Up/Mute Button
Short press the button to scroll up the function menu. Holding the button for more than 2 seconds will silence the alarm. For more
information about the /Mute Button, please refer to the Up Function Setup Guide.
6 Enter/Setup Button
Press the button for 2 seconds to enter the setup menu and then select the functions for conguration. For more information about the
Enter/Setup Button, please refer to the Function Setup Guide.
7 USB Charging Ports
The USB Charging ports provide 5V 1A power output. 2.
8 ttery and Surge Protected Outlets Ba
The UPS has ve battery powered/surge suppression outlets for connected equipment ensure temporary uninterrupted operation of your to
equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other
large electrical devices into the Battery and Surge Protected Outlets The power demands of these devices may overload and “ ”.
damage the unit.)
9 Full-Time Surge Protection Outlets
The UPS has ve surge suppression outlets to provide protection against surges and spikes.
10 Circuit Breaker
Located on the back of the UPS, the circuit breaker provides overload and fault protection.
11 Serial/USB Ports to PC
The USB port allows connection and communication between the USB t on the computer and the S. por UP
12 Communication Protection Ports
Communication protection ports will protect any standard modem, fax telephone line, network or Ethernet connection (RJ11/RJ45). ,
13 Wiring Fault Indicator (red)
This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If
this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The UPS will
not provide surge protection without being plugged into a grounded and properly wired wall outlet.
14 Coax/Cable/DSS Surge Protection
The Coax/Cable/DSS protection ports will protect any cable modem, CATV converter, or DSS receiver.
REPLACING THE BATTERY
Replacement of batteries located in an OPERATOR ACCESS AREA.
1. When replacing batteries, replace with the same number of the following battery: CyberPower / RB1280A for the BRG850AVRLCD and
CyberPower / RB1290 for the BRG1000AVRLCD.
2. 12 Risk of Energy HazardCAUTION! , V, maximum 9 Ampere-hour battery. Before replacing batteries, remove conductive jewelry such
as chains, wrist watches, and rings. High energy conducted through these materials could cause severe burns.
3. Do not dispose of batteries in a re. The batteries may explode. CAUTION!
4. Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. CAUTION!
5. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed CAUTION:
when working on batteries:
1) Remove watches rings, or other metal objects.
2) Use tools with insulated handles.
CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING
TO LOCAL REGULATIONS.
BATTERY REPLACEMENT PROCEDURE:
1. Turn o and unplug all connected equipment.
2. Turn the UPS o and unplug it from the AC power source.
3. Turn the UPS on its side.
4. Remove the front panel retaining screws located on the bottom of the UPS.
5. Slide the battery compartment cover (front panel) completely o of the unit.
6. Disconnect the battery wires from the battery.
7. Remove the battery from the compartment.
8. Put the battery back into the compartment.
9. Install the replacement battery by connecting the red wire ( and black wire (-) to the same color connectors from the battery pack. +)
10. Slide back the battery compartment cover and tighten the retaining screws.
11. Recharge the UPS for 8-16 hours to fully charge the battery.
REMINDER: Batteries are consider ed HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead-acid batteries
collect used batteries for recycling, as required by local regulations.
1. ONLINE: The UPS is supplying utility power to connected equipment.
2. BATTERY: During a severe brownout or blackout, this icon appears and an alarm sounds
(two short beeps followed by a pause) to indicate the UPS is operating f m its internal batteries. ro
During a prolonged brownout or blackout, the alarm will beep rapidly every 1/2 second to indicate
the UPS’s batteries are nearly out of power. You should save files and turn o your equipment
immediately or allow the software to shut the system down.
3. Energy-Saving: The UPS in energy-saving bypass mode. See CyberPower is
GreenPower UPS
TM Technology section for more information.
4. LOAD capacity / Sensitivity setup: LOAD capacity: This meter displays the approximate
output load level (in 20% increments) of the UPS battery outlets.
Sensitivity setup: This meter is also used to setup the UPS sensitivity when you are in the programming mode. If the connected equipment
can tolerate more power events (example: unstable power often associated with stormy weather), select Low Sensitivity and the UPS will go
to Battery Mode less often. If the connected equipment is more sensitive to power events, select High Sensitivity and the UPS will go to
Battery Mode more often.
5. BATTERY capacity: This meter displays the approximate charge level (in 20% increments) of the UPS s internal battery. During a
blackout or severe brownout, the UPS switches to battery power, the BATTERY icon appears, and the charge level decreases.
6. FAULT: This icon appears if there is a problem with the U Press the POWER button to turn the UPS o. PS.
F01: Battery Mode or AC/Utility Power Mode Overload fault (Unplug at least one piece of equipment from battery outlets turn the and
UPS again.) on
F02: Battery Output Short fault (Unplug at least one piece of equipment from battery outlets and turn the UPS on again.)
F03: Charger Fault (Contact CyberPower Systems for support.)
F04: Internal Fault (Contact CyberPower Systems for support.)
7. OVER LOAD: This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload,
unplug one piece of equipment from the battery-supplied outlets at a time until the icon turns o and the alarm stops.
8. SCHEDULE: Users can setup the schedule to turn on and shut down the computer and UPS through PowerPanel
® Personal Edition
software. The LCD display will show how much time is left before the UPS will turn back on or shut down.
9. ESTIMATED RUNTIME: This displays the run time estimate of the UPS with current battery capacity and load.
10. OUTPUT Meter: This meter measure, in real time, the AC voltage that the UPS system is providing to the computer, such as normal AC
line mode, AVR mode, and battery backup mode. (Note: The OUTPUT meter shows the status of the battery backup outlets in terms of load,
frequency, and voltage.)
11. INPUT Meter: This meter measures the AC voltage that the UPS system is receiving from the utility wall outlet. The UPS is designed,
through the use of automatic voltage regulation, to continuously correct output voltage to connected equipment to a safe 110/120 voltage
BASIC OPERATION
INSTALLING YOUR UPS SYSTEM
IMPORTANT SAFETY INSTRUCTIONS
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
PRODUCT REGISTRATION


Produkt Specifikationer

Mærke: CyberPower
Kategori: Uafbrydelig strømforsyning (UPS)
Model: Intelligent LCD BRG850AVRLCD

Har du brug for hjælp?

Hvis du har brug for hjælp til CyberPower Intelligent LCD BRG850AVRLCD stil et spørgsmål nedenfor, og andre brugere vil svare dig




Uafbrydelig strømforsyning (UPS) CyberPower Manualer

Uafbrydelig strømforsyning (UPS) Manualer

Nyeste Uafbrydelig strømforsyning (UPS) Manualer