Battery Replacement
Instructions
CyberPower encourages environmentally sound
methods for disposal and recycling of its UPS and
batteries. Please dispose of and/or recycle your
UPS and batteries in accordance to the local
regulations of your state.
MODEL: CP900AVRa, CP1200AVRa, CP1350AVRLCDa,
CP1500AVRTa, LX1100G, LX1325GU, LX1500GU,
CST135XLU, CST150XLU
1 2
IMPORTANT SAFETY INSTRUCTIONS
Read and follow the important safety instructions before
servicing the batteries. Visit CyberPower o˜cial website
www.cyberpower.com or contact your dealer for more
information on battery replacement.
CAUTION! Use only the specified CyberPower replacement
battery, or battery pack.
CAUTION! Do not dispose of batteries in a fire. The batteries
may explode.
CAUTION! Do not open or mutilate batteries. Released
material is harmful to the skin and eyes. It may be toxic.
Take the following precautions before replacing the battery:
1. Remove watches, rings, or other metal objects.
2. Use tools with insulated handles.
3. Wear rubber gloves and boots.
4. Do not lay tools or metal parts on top of batteries.
5. Determine if battery is inadvertently grounded. If
inadvertently grounded, remove source from ground.
CONTACT WITH ANY PART OF A GROUNDED BATTERY
CAN RESULT IN ELECTRICAL SHOCK. The likelihood of
such shock can be reduced if such grounds are removed
during installation and maintenance (applicable to
equipment and remote battery supplies not having a
grounded supply circuit).
1
Smart APP Intelligent LCD Series
MODEL: OR500LCDRM1U, OR700LCDRM1U, OR1000LCDRM1U,
OR1500LCDRM1U
Intelligent LCD Series, AVR Series
MODEL: CP600LCD, CP825LCD, CP800AVR, CP685AVR-G,
CP825AVR-G, CP685AVRLCD-G, CP825AVRLCD-G,
AVRG750U, AVRG900U, AVRG750LCD, AVRG900LCD
2 31
1. Place the UPS on its top and remove the retaining screw (figure 1).
2. Slide the battery compartment cover completely o˛ of the unit
(figure 2).
3. Remove the battery from the compartment and disconnect the
battery wires from the battery. Install the replacement battery by
connecting the red wire to the positive (+) terminal and the black
wire to the negative (-) terminal of the battery. (figure 3)
4. Slide the battery compartment cover over the battery and tighten
the retaining screw.
5. Charge the unit for 4–8 hours to ensure the UPS performs
expected runtimes.
MODEL: CP850AVRLCD, CP1000AVRLCD
1 2 3
1. Place the UPS on its side and locate the battery compartment
cover on the bottom of the UPS. Remove the four (4) retaining
screws and pull the battery compartment cover o˛ the UPS
(figure 1 & 2).
2. Remove the battery from the compartment and disconnect the
battery wires from the batteries. Install the replacement batteries
by connecting the red wire and black wire to the same color wires
from the battery pack. Put the battery pack into the compartment
(figure 3).
3. Slide the battery compartment cover over the battery and tighten
the retaining screw. Charge the unit for 4–8 hours to ensure the
UPS performs expected runtimes.
2
MODEL: CPS1500AVR
1 2 3
Standby Series
MODEL: RT650, RT650EI
1 2
3 4
1. Place the UPS on its side and remove the retaining screw.
2. Slide the battery compartment cover completely o˛ of the unit.
3. Remove the battery from the compartment and disconnect the
battery wires from the battery.
4. Install the replacement battery by connecting the red wire and
black wire to the positive (+) and negative (-) terminal of the
battery. Put the battery back into the compartment.
5. Slide back the battery compartment cover and tighten the
retaining screw.
6. Charge the unit for 8 hours to ensure the UPS performs
expected runtimes.
3
Smart APP SINEWAVE Series
MODEL: PR750LCD, PR750 JP, PR750ELCD
1 2
AVR Series
MODEL: BRG850AVRLCD, BRG1000AVRLCD, CP850AVRLCDa,
CP1000AVRLCDa
1 2
3 4
1. Place the UPS on its side.
2. Remove the front panel retaining screws located on the bottom
of the UPS.
3. Slide the battery compartment cover (front panel) completely
o˛ of the unit.
4. Disconnect the battery wires from the battery and remove the
battery from the compartment.
5. Install the replacement battery by connecting the red wire (+) and
black wire (-) to the same color connectors from the battery pack.
Put the battery back into the compartment.
6. Slide back the battery compartment cover and tighten the
retaining screws.
7. Charge the UPS for 8-16 hours to ensure the UPS performs
expected runtimes.
MODEL: BRG1350AVRLCD, BRG1500AVRLCD, CP1500AVRLCDa
1 2
3 4
1. Place the UPS on its side.
2. Remove the front panel retaining screws located on the bottom
of the UPS.
3. Slide the battery compartment cover (front panel) completely
o˛ of the unit.
4. Disconnect the battery wires from the batteries and remove the
batteries from the compartment.
5. Install the replacement batteries by connecting the red wire (+) and
black wire (-) to the same color connectors from both the upper and
lower battery pack. Put the batteries back into the compartment.
Note: Make sure both batteries are new and replaced at the
same time to ensure maximum battery lifespan.
6. Slide back the battery compartment cover and tighten the
retaining screws.
7. Charge the UPS for 8-16 hours to ensure the UPS performs
expected runtimes. 4
MODEL: PR1500LCD, PR1500 JP, PR1500ELCD
1 2 3 4
MODEL: CP900AVR, CP1200AVR, CP1500AVRT,
CP1285AVRLCD, CP1350AVRLCD, CP1500AVRLCD
1 2 3
4 5 6
1. Place the UPS on its side to locate and remove the front panel
retaining screw from the bottom of the UPS.
2. Slide the cover (front panel) towards the bottom of the UPS.
3. Detach the cover from the unit.
4. Disconnect the cable located at the top of the cover and remove
the cover from the unit.
5. Disconnect the battery wires from the batteries.
6. Remove the batteries from the compartment.
7. Install the replacement batteries by connecting the red and black
wires to the same color wires from the battery pack. Put the
battery pack back into the compartment.
8. Replace the battery compartment cover and tighten the retaining
screw.
9. Charge the unit for 4-8 hours to ensure the UPS performs
expected runtimes.
MODEL: BRG1500AVRLCD2, CP1350AVRLCD3,
CP1500AVRLCD3
1 CONNECT BATTERY
(+) RED (-) BLACK
2
3
4
5
1. Switch o˛ and unplug all the connected equipment.
2. Switch o˛ the UPS and disconnect it from the wall outlet.
3. Place the product on its side, on a solid and stable surface.
4. Loosen the battery compartment cover screws.
5. Press on the locking latch and slide the battery compartment
cover.
6. Using the handles on both sides of the battery pack, lift the
battery pack 30 degrees upward to expose the battery connector.
Connect the wires as shown above.
7. Replace the new battery pack into the unit and connect the wires
as above steps.
8. Align the side rails on the cover with the rails on the UPS and slide
the cover till it locks and screws in position.
9. Recharge the UPS for 8-16 hours to fully charge the battery.
5
MODEL: PR2200LCD, PR3000LC, PR2200ELCD, PR3000ELCD
1 2 3 4
1 2 3
4 5
1. Remove the front panel of the UPS. 1. Remove the front panel of the UPS and two screws from the
4 2. Remove two screws from the battery compartment cover and
4 5 battery compartment cover and slide the cover completely o˛
slide the cover completely o˛ of the unit.
3 4 of the unit.
2. Pull out the battery pack on the outside from the compartment.
Disconnect the battery connector from the batteries.
3. Before removing the battery pack on the inside, unlock the
cable tie and pull out the battery wires. Disconnect the battery
3. Remove the batteries from the compartment. Disconnect the
battery wires from the batteries.
4. Install the replacement batteries by connecting the wire bundle
(composed of one red wire and one black wire) to the
connector from the battery pack.
1. Remove the right side front panel. connector from the batteries.
5. Put the batteries back into the compartment. Re-install the
1. Remove the right side front panel. 2. Remove the two retaining screws for the cable protection cover
2. Remove the three retaining screws for the cable protection cover and remove the cover. 1. Remove the front panel of the UPS. 4. Install the replacement battery pack on the inside by
connecting the wire bundle connector (composed of one red
battery compartment cover and tighten the retaining screws.
5 6
Put the front panel back on the UPS.
2. Pull out both round knobs and remove the battery compartment
and remove the cover. 3. Disconnect the black and red cable. wire and one black wire) to the connector from the battery
pack. Lock the battery wires back with the cable tie.
6. Connect to AC power and charge the new batteries for up to 16
cover completely o˛ of the unit.
3. Disconnect the black and red cable. 4. Remove the four retaining screws holding the battery pack in hours to insure a full charge.
3. Remove the batteries from the compartment.
4. Remove the one retaining screw holding the battery pack in place. place. 5. Install the replacement batteries on the outside by connecting
4. Disconnect the battery wires from the batteries.
5. Remove the battery pack. 5. Remove the battery pack. the wire bundle connector (composed of one red wire and one
MODEL: PR2000SL JP, PR3000SL JP, PR2200LCDSL,
5. Install the replacement batteries by connecting the wire bundle
6. Install the new battery pack. Assemble the screws, cover, cable 6. Install the new battery pack. Assemble the screws, cover, cable black wire) to the connector from the battery pack. Put the
(+) Red (composed of one red wire and one black wire) to the connector PR3000LCDSL, PR2200ELCDSL, PR3000ELCDSL,
and front panel in the reverse order of the previous steps. Charge and front panel in the reverse order of the previous steps.
the unit for 4-8 hours to ensure the UPS performs expected Charge the unit for at least 12 hours to ensure the UPS performs
battery pack on the outside back into the compartment.
(-) Black from the battery pack. Put the batteries back into the compartment. M550L, M750L, M1100XL 6. Re-install the battery compartment cover and tighten the
6. Re-install the battery compartment cover and push both round
runtimes. expected runtimes. retaining screws and put the front panel back on the UPS.
7. Connect to AC power and charge the new batteries for up to 16
7 8 knobs back into place. Put the front panel back on the UPS. 1 2
7. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.
MODEL: OR1500LCDRM2U, OR2200LCDRM2U hours to insure a full charge. Note: The battery pack on the outside has a fuse, while the
OR1500LCDRTXL2U, OR2200LCDRTXL2U battery pack on the inside does not.
OR1500LCDRT2U, OR2200LCDRT2U MODEL: PR1000LCD, PR1000 JP, PR1000ELCD
MODEL: PR750LCD3C, PR750LCD3CJP
1 2 3 1 2
(-) Black
(+) Red 1 2 3 4 5
3 4
1. Place the UPS on its side and remove the two retaining screws
located on the bottom of the UPS.
2. Slide the battery compartment cover completely o˛ the unit.
3. Remove the battery which is located on the right side from the 3 4
compartment and disconnect the battery wires from the right 4 5 6
side of the battery.
4. Slide the remaining battery from the left side to the right side of
the compartment. 1. Turn o˛ and unplug all connected equipment.
1. Remove the front panel of the UPS.
5. Remove the remaining battery from the compartment and
disconnect the battery wires from it. 2. Turn the UPS o˛ and unplug it from the AC power source.
2. Remove two screws from the battery compartment cover and 3. Push the buckle and remove the front panel of the UPS.
slide the cover completely o˛ of the unit.
6. Install the "left side" replacement battery by connecting the
yellow wire (+) to the red connector from the battery and the 4. Loosen the screw and remove the battery compartment plate.
3. Remove the batteries from the compartment.
1. Remove the right side front panel. 1. Remove the front panel of the UPS. 5. Remove the batteries from the compartment.
4. Disconnect the battery wires from the batteries.
2. Remove the three retaining screws for the cable protection cover
black wire (-) to the black connector from the battery. Place the 2. Remove two screws from the battery compartment cover and 6. Disconnect the battery wires from the batteries.
5. Install the replace batteries by connecting the red wire (+) and
and remove the cover.battery into the left side of the compartment. slide the cover completely o˛ of the unit. 7. Install the replacement batteries by connecting the wire bundle
black wire (-) to the same color connectors from the battery pack.
3. Remove the two retaining screws from the cable connectors.
7. Install the "right side" replacement battery by connecting the red 3. Remove the batteries from the compartment. Disconnect the (composed of one red wire and one black wire) to the connector
6. Put the batteries back into the compartment.
wire (+) to the red connector from the battery and yellow wire 4. Disconnect the black and red cable. battery wires from the batteries. from the battery pack.
8. Put the batteries back into the compartment.
7. Re-install the battery compartment cover and tighten the
retaining screws.
(-) to the black connector from the battery. Place the battery into 5. Remove the four retaining screws holding the battery pack in 4. Install the replacement batteries by connecting the wire bundle
the right side of the compartment. place. (composed of one red wire and one black wire) to the 9. Re-install the battery compartment plate and tighten the screw
8. Put the front panel back on the UPS.
Note: Make sure both batteries are new and replaced at the same 6. Remove the battery pack. connector from the battery pack. back into place.
10. Put the front panel back on the UPS.
9. Connect to AC power and charge the new batteries for up to 16
time to ensure maximum battery lifespan. 7. Install the new battery pack. Assemble the screws, cover, cable 5. Put the batteries back into the compartment. Re-install the hours to insure a full charge.
8. Slide back the battery compartment cover and tighten the and front panel in the reverse order of the previous steps. Charge battery compartment cover and tighten the retaining screws. 11. Connect to AC power and charge the new batteries for up to 8
retaining screws. the unit for at least 12 hours to ensure the UPS performs Put the front panel back on the UPS. hours to insure a full charge.
9. Charge the UPS for 8-16 hours to ensure the UPS performs expected runtimes. 6. Connect to AC power and charge the new batteries for up to 16
expected runtimes. hours to insure a full charge.
6 7 8 9 10 11
Copyright © 2024 Cyber Power Systems, Inc. All rights reserved.
Produkt Specifikationer
Mærke: | CyberPower |
Kategori: | Accu |
Model: | RB1270X2F |
Har du brug for hjælp?
Hvis du har brug for hjælp til CyberPower RB1270X2F stil et spørgsmål nedenfor, og andre brugere vil svare dig
Accu CyberPower Manualer
24 December 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
21 September 2024
6 September 2024
30 August 2024
19 August 2024
Accu Manualer
- Accu Bosch
- Accu Ozito
- Accu Sony
- Accu Canon
- Accu Panasonic
- Accu Metabo
- Accu DeWalt
- Accu RYOBI
- Accu LG
- Accu Victron Energy
- Accu TOA
- Accu Gardena
- Accu Epson
- Accu Sandberg
- Accu Sennheiser
- Accu McCulloch
- Accu Worx
- Accu Nikon
- Accu Biltema
- Accu Vonroc
- Accu Milwaukee
- Accu Black And Decker
- Accu Mestic
- Accu Einhell
- Accu Leica
- Accu Hikoki
- Accu Greenworks
- Accu Kress
- Accu Cramer
- Accu EGO
- Accu Ranex
- Accu Targus
- Accu Deltaco
- Accu Fein
- Accu Tripp Lite
- Accu Powerplus
- Accu Digitus
- Accu Ansmann
- Accu Varta
- Accu HQ
- Accu EnerGenie
- Accu DJI
- Accu APC
- Accu Cobra
- Accu Fluke
- Accu Hikvision
- Accu Monacor
- Accu Xtorm
- Accu Berg
- Accu Hähnel
- Accu Cortina
- Accu Watson
- Accu Arris
- Accu SOUNDBOKS
- Accu Shure
- Accu Aluratek
- Accu Speed-Link
- Accu Scosche
- Accu Duracell
- Accu Toolcraft
- Accu Crestron
- Accu Fuxtec
- Accu Sungrow
- Accu Energizer
- Accu Enphase
- Accu Growatt
- Accu Impact
- Accu Neewer
- Accu Bolt
- Accu Anton/Bauer
- Accu Cocraft
- Accu Inovonics
- Accu A-solar
- Accu Stinger
- Accu Kensington
- Accu Valcom
- Accu Conrad
- Accu For_Q
- Accu Wentronic
- Accu Team Orion
- Accu SolarEdge
- Accu Venom
- Accu BlackVue
- Accu Red Power
- Accu Ultron
- Accu E-flite
- Accu Whistler
- Accu PNY
- Accu PowerDrive
- Accu LSI
- Accu Variotek
- Accu Lenmar
- Accu Renata
- Accu Fxlion
- Accu FeinTech
- Accu Verico
- Accu Levolta
- Accu HART
- Accu TCW Technologies
- Accu Enerdrive
- Accu PAG
Nyeste Accu Manualer
22 December 2024
15 December 2024
13 December 2024
13 December 2024
13 December 2024
13 December 2024
13 December 2024
13 December 2024
13 December 2024
13 December 2024