This air conditioner meets strict safety and operating
standards. The installer of this unit must install or service
this unit so it operates safely and efficiently.
The lightning flash with arrowhead symbol,
within an equilateral triangle is intended to
alert the user to the presence of uninsulat-
ed dangerous voltage within the product’s
enclosure that may be of sufficient magni-
tude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and main-
tenance (servicing) instructions in the liter-
ature accompanying the appliance.
Contact Installer if Necessary:
The installation instructions are for a experienced
installer. If you are not an experienced installer, contact a
local installer for help. If you require help with service,
contact your certified dealer or Daewoo Electronics for
additional instructions.
If Unit is Installed Improperly:
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this manual.
Precautions When Wiring:
Do not plug in the unit until all connections (tubing,
drain hose, mounting, etc.) have been made and dou-
ble-checked.
High voltages are present in this unit and are very dan-
gerous. Please refer to these instructions and diagrams
when wiring. Improper connections or inadequate
grounding can cause accidental injury.
This unit must be grounded in accordance with local
electrical codes.
Connect wires and pipes securely and tightly as loose
connections/wiring may cause overheating at connec-
tions and a possible fire hazard.
Precautions When Transporting:
When transporting the unit, be very careful and get help
as the units are very heavy. Be careful of sharp edges
on the units also.
Precautions When Installing:
When installing in a ceiling or wall, make sure the
ceiling/wall is strong enough to hold the unit’s weight. A
frame may be necessary for added support.
When installing in a room, make sure the tubes are
well insulated to protect the walls and furniture from
sweating of the tubes.
• When installing in moist or uneven locations, make
sure to use a raised level concrete pad or concrete
blocks to provide a level, solid foundation for the out-
door unit; this prevents water damage and vibration.
When installing in an area of high winds, make sure
to securely anchor the outdoor unit down with bolts and
a metal frame.
When Connecting Refrigerant Tubing:
Keep all tubing as short as possible.
Use the flare method for connecting tubing.
Apply refrigerant lubricant to the matching surfaces of
the flare and union tubes before connecting them, then
tighten , making sure not to overtighten.
• Check the tubes carefully for leaks before starting the
test run.
When Servicing:
Make sure the power is off and the unit is unplugged
before opening the unit to troubleshoot or repair electri-
cal parts and wiring.
Keep your fingers and clothing away from any moving
parts.
• Clean up the sight after you finish, making sure no
metal scraps and wiring are left in the unit.
• The Air conditioner shall be installed in accordance with
the nationed wiring regulation.
SAFETY INSTRUCTIONS
1
PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE
INSTALLING AND OPERATING THE UNIT:
IMPORTANT NOTES
Adhere to all safety instructions and warnings
throughout this manual.
Read this manual carefully before installing or operat-
ing this unit to become familiar with its features and
obtain the performance that will bring you continued
enjoyment for many years.
Follow each installation or repair step exactly as
shown in the manual.
Observe all local, state and national electric codes.
Contact your local government for more information
on electrical codes.
WARNING:
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSON-
AL INJURY OR DEATH. ONLY A QUALIFIED, EXPERI-
ENCED ELECTRICIAN/INSTALLER SHOULD ATTEMPT
TO WIRE THIS SYSTEM.
THE APPLIANCE IS NOT INTENDED FOR USE BY CHIL-
DRENOR INFIRM PERSONS WITHOUT SUPERVISION.
YOUNG CHILDREN SHOULD BE SUPERVISED TO
ENSURE THAT DO NOT PLAY WITH THE APPLIANCE


Produkt Specifikationer

Mærke: Daewoo
Kategori: Klimaanlæg
Model: dsb 182 lh

Har du brug for hjælp?

Hvis du har brug for hjælp til Daewoo dsb 182 lh stil et spørgsmål nedenfor, og andre brugere vil svare dig




Klimaanlæg Daewoo Manualer

Klimaanlæg Manualer

Nyeste Klimaanlæg Manualer

NewAir

NewAir AC-14100H Manual

21 November 2024
NewAir

NewAir NAC14KWHH2 Manual

21 November 2024
NewAir

NewAir NAC08KWH01 Manual

21 November 2024
Gree

Gree GPAC12D Manual

20 November 2024
Gree

Gree GPAC09D Manual

20 November 2024
Daitsu

Daitsu ABD 18K DB Manual

20 November 2024
Daitsu

Daitsu ABD 12K DB Manual

20 November 2024
Daitsu

Daitsu APD 09X Manual

20 November 2024
Daizuki

Daizuki DX1C12426-22 Manual

18 November 2024