Daikin FTXJ35A2V1BB9 Manual

Daikin Ikke kategoriseret FTXJ35A2V1BB9

Læs nedenfor 📖 manual på dansk for Daikin FTXJ35A2V1BB9 (72 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 16 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/72
User reference guide
Daikin room air conditioner
FTXJ20A2V1BW9
FTXJ25A2V1BW9
FTXJ35A2V1BW9
FTXJ42A2V1BW9
FTXJ50A2V1BW9
FTXJ20A2V1BB9
FTXJ25A2V1BB9
FTXJ35A2V1BB9
FTXJ42A2V1BB9
FTXJ50A2V1BB9
FTXJ20A2V1BS9
FTXJ25A2V1BS9
FTXJ35A2V1BS9
FTXJ42A2V1BS9
FTXJ50A2V1BS9
Table of Contents
User reference guide
2
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
Table of Contents
1 About the documentation 4
1.1 About this document...................................................................................................................................................... 4
1.2 Meaning of warnings and symbols ................................................................................................................................ 5
2 User safety instructions 7
2.1 General ........................................................................................................................................................................... 7
2.2 Instructions for safe operation ...................................................................................................................................... 8
3 About the system 12
3.1 Indoor unit...................................................................................................................................................................... 12
3.1.1 Daikin eye indication lamp............................................................................................................................. 13
3.2 About the user interface ................................................................................................................................................ 14
3.2.1 Components: Wireless remote control......................................................................................................... 14
3.2.2 To operate the wireless remote control ....................................................................................................... 15
3.2.3 Status: Wireless remote control LCD ............................................................................................................ 15
3.2.4 Main menu: Wireless remote control........................................................................................................... 17
4 Before operation 20
4.1 To insert the batteries.................................................................................................................................................... 20
4.2 To mount the wireless remote control magnetic holder .............................................................................................. 21
4.3 To turn on the power supply.......................................................................................................................................... 21
4.4 Indoor unit setting.......................................................................................................................................................... 21
4.4.1 Brightness of the Daikin eye.......................................................................................................................... 22
4.4.2 Open the front panel ..................................................................................................................................... 22
4.4.3 Wireless LAN connection............................................................................................................................... 22
4.4.4 Vertical airflow function ................................................................................................................................ 27
4.4.5 About indoor unit installation position ......................................................................................................... 27
4.4.6 Keep dry ......................................................................................................................................................... 28
4.5 Wireless remote control setting .................................................................................................................................... 28
4.5.1 To set contrast of the LCD ............................................................................................................................. 29
4.5.2 To set brightness of the LCD.......................................................................................................................... 29
4.5.3 To set automatic LCD turn off time............................................................................................................... 29
4.5.4 To set automatic send after select................................................................................................................ 29
4.5.5 To set a different channel of the indoor unit infrared signal receiver ......................................................... 30
5 Operation 31
5.1 Operation range ............................................................................................................................................................. 31
5.2 When to use which feature............................................................................................................................................ 31
5.3 Operation mode and temperature setpoint.................................................................................................................. 33
5.3.1 To start/stop operation mode and to set the temperature ......................................................................... 34
5.4 Airflow rate..................................................................................................................................................................... 34
5.4.1 To adjust the airflow rate .............................................................................................................................. 35
5.5 Airflow direction............................................................................................................................................................. 35
5.5.1 To adjust vertical airflow direction................................................................................................................ 37
5.5.2 To adjust horizontal airflow direction ........................................................................................................... 38
5.5.3 To use 3D airflow direction............................................................................................................................ 38
5.5.4 To start/stop Comfort airflow operation ...................................................................................................... 39
5.6 Intelligent eye operation................................................................................................................................................ 39
5.6.1 To start/stop Intelligent eye operation ......................................................................................................... 39
5.7 Powerful operation ........................................................................................................................................................ 40
5.7.1 To start/stop Powerful operation.................................................................................................................. 40
5.8 Econo operation ............................................................................................................................................................. 41
5.8.1 To start/stop Econo operation ...................................................................................................................... 41
5.9 Outdoor unit quiet operation ........................................................................................................................................ 42
5.9.1 To start/stop Outdoor unit quiet operation.................................................................................................. 42
5.10 Flash Streamer (air cleaning) operation ........................................................................................................................ 43
5.10.1 To start/stop Flash Streamer (air cleaning) operation.................................................................................. 43
5.11 Clock and timer setting .................................................................................................................................................. 43
5.11.1 The clock setting ............................................................................................................................................ 43
5.11.2 OFF/ON timer operation................................................................................................................................ 45
5.11.3 Weekly timer operation................................................................................................................................. 47
5.12 About Multi system ........................................................................................................................................................ 49
5.12.1 Priority room setting...................................................................................................................................... 49
5.12.2 Night quiet mode........................................................................................................................................... 50
5.12.3 Cooling/heating mode lock in Multi-system ................................................................................................. 50
1 About the documentation |
User reference guide
5
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
1.2 Meaning of warnings and symbols
DANGER
Indicates a situation that results in death or serious injury.
DANGER: RISK OF ELECTROCUTION
Indicates a situation that could result in electrocution.
DANGER: RISK OF BURNING/SCALDING
Indicates a situation that could result in burning/scalding because of extreme hot or
cold temperatures.
DANGER: RISK OF EXPLOSION
Indicates a situation that could result in explosion.
WARNING
Indicates a situation that could result in death or serious injury.
WARNING: FLAMMABLE MATERIAL
CAUTION
Indicates a situation that could result in minor or moderate injury.
NOTICE
Indicates a situation that could result in equipment or property damage.
INFORMATION
Indicates useful tips or additional information.
Symbols used on the unit:
Symbol Explanation
Before installation, read the installation and operation
manual, and the wiring instruction sheet.
Before performing maintenance and service tasks, read the
service manual.
For more information, see the installer and user reference
guide.
The unit contains rotating parts. Be careful when servicing or
inspecting the unit.
Symbols used in the documentation:
Symbol Explanation
Indicates a figure title or a reference to it.
Example: " 1–3 Figure title" means "Figure 3 in chapter 1".
2 User safety instructions |
User reference guide
10
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
WARNING
The refrigerant inside the unit is mildly flammable, but
normally does NOT leak. If the refrigerant leaks in the
room and comes in contact with fire from a burner, a
heater, or a cooker, this may result in fire, or the
formation of a harmful gas.
Turn OFF any combustible heating devices, ventilate the
room, and contact the dealer where you purchased the
unit.
Do NOT use the unit until a service person confirms that
the part from which the refrigerant leaked has been
repaired.
WARNING
Do NOT pierce or burn refrigerant cycle parts.
Do NOT use cleaning materials or means to accelerate
the defrosting process other than those recommended
by the manufacturer.
Be aware that the refrigerant inside the system is
odourless.
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without
continuously operating ignition sources (e.g. open flames,
an operating gas appliance, or an operating electric
heater). The room size shall be as specified in the General
safety precaution.
DANGER: RISK OF ELECTROCUTION
To clean the air conditioner or air filter, be sure to stop
operation and turn all power supplies OFF. Otherwise, an
electrical shock and injury may result.
CAUTION
After a long use, check the unit stand and fitting for
damage. If damaged, the unit may fall and result in injury.
CAUTION
Do NOT touch the heat exchanger fins. These fins are
sharp and could result in cutting injuries.
2 User safety instructions |
User reference guide
11
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
WARNING
Be careful with ladders when working in high places.
WARNING
Improper detergents or cleaning procedure may cause
damage on plastic components or water leakage. Splashed
detergent on electric components, such as motors, may
cause failure, smoke or ignition.
DANGER: RISK OF ELECTROCUTION
Before cleaning, be sure to stop the operation, turn the
breaker OFF or pull out the supply cord. Otherwise, an
electrical shock and injury may result.
WARNING
Stop operation and shut OFF the power if anything
unusual occurs (burning smells etc.).
Leaving the unit running under such circumstances may
cause breakage, electrical shock or fire. Contact your
dealer.
3 About the system |
User reference guide
12
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
3 About the system
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
CAUTION
The indoor unit contains radio equipment, minimum separation distance between
the radiating part of the equipment and the user is 10 cm.
NOTICE
Do NOT use the system for other purposes. In order to avoid any quality
deterioration, do NOT use the unit for cooling precision instruments, food, plants,
animals, or works of art.
3.1 Indoor unit
CAUTION
Do NOT insert fingers, rods or other objects into the air inlet or outlet. When the fan
is rotating at high speed, it will cause injury.
INFORMATION
The sound pressure level is less than 70dBA.
WARNING
Do NOT modify, disassemble, remove, reinstall or repair the unit yourself as
incorrect dismantling or installation may cause an electrical shock or fire. Contact
your dealer.
In case of accidental refrigerant leaks, make sure there are no naked flames. The
refrigerant itself is entirely safe, non-toxic and mildly flammable, but it will
generate toxic gas when it accidentally leaks into a room where combustible air
from fan heaters, gas cookers, etc. is present. Always have qualified service
personnel confirm that the point of leakage has been repaired or corrected
before resuming operation.
b
a
j
i
c
e
d
g
h
f
4 Before operation |
User reference guide
21
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
4.2 To mount the wireless remote control magnetic holder
cba
aWireless remote controller
bScrews (field supply)
cWireless remote controller magnetic holder
1Choose a place where the signals reach the unit.
2Attach the holder with screws to the wall or a similar location.
3Hang the wireless remote control on the holder.
INFORMATION
The wireless remote control holder is magnetic. Make sure to install the holder with
the right side up.
4.3 To turn on the power supply
1Turn the circuit breaker on.
Result: The flap of the indoor unit will open and close to set the reference position.
4.4 Indoor unit setting
1Enter the main menu by pressing and navigate to the indoor unit setting
menu using and . Press to enter the menu.
Indoor unit setting menu
2Perform the settings listed below.
3Press to return to the main menu or press to exit to the home screen.
Setting list
4.4.1 Brightness of the Daikin eye .................................................................................................................................. 22
4.4.2 Open the front panel ............................................................................................................................................. 22
4.4.3 Wireless LAN connection ....................................................................................................................................... 22
4.4.4 Vertical airflow function......................................................................................................................................... 27
4.4.5 About indoor unit installation position.................................................................................................................. 27
4.4.6 Keep dry ................................................................................................................................................................. 28
4 Before operation |
User reference guide
22
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
4.4.1 Brightness of the Daikin eye
You can set the brightness of the Daikin eye on the indoor unit to high, low or turn
it OFF.
To set the brightness of the Daikin eye
1In the indoor unit setting menu, navigate to the brightness of the Daikin eye
setting screen using and .
High
H
O
Low
H
O
OFF
H
O
2Change the setting using and .
Result: The brightness of the Daikin eye changes.
3Press again to return to the main menu or press to return to the home
screen.
4.4.2 Open the front panel
The front panel opens automatically when the operation starts. When you want to
open the front panel when the operation is OFF, use this feature. duringExample:
maintenance.
To open the front panel using the wireless remote control
1Make sure the operation is OFF. If not, turn it OFF using .
2In the indoor unit setting menu, navigate to the open the front panel screen
using and .
Open the front panel screen
SEND
3Press to confirm.
Result: The front panel opens.
4Press again to close the front panel or press to return to the home
screen.
4.4.3 Wireless LAN connection
Simply connect your unit to your home network and download the app to change
the thermostat, set temperature schedules, review your energy consumption and
more.
For details on specifications, setting methods, FAQ, troubleshooting tips, visit
app.daikineurope.com.
The customer is responsible for providing:
4 Before operation |
User reference guide
24
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
INFORMATION
If the QR code is difficult to read, switch the displayed QR code using or , then
try again.
To set the wireless connection
There are two options to connect the wireless adapter to your home network.
Using a smart device (smartphone, tablet) and SSID (Service Set Identifier) and
KEY (password)
Using the WPS (Wi-Fi Protected Setup) button on your Wi-Fi router.
For more information and FAQ, refer to .
app.daikineurope.com
Note: Setting is done by the wireless remote control in the wireless LAN setting
menu. During setting, always aim the wireless remote control at the infrared signal
receiver on the unit.
INFORMATION
Make sure operation is stopped before setting the wireless connection. Connection
CANNOT be made when the unit is in operation.
1 Stop operation before setting the wireless connection.
2Make sure the wireless router is close enough to the unit and nothing
obstructs the signal.
Menu Description
ON = Wireless LAN ON (AP mode/RUN mode (SSID + KEY)
connection setting)
OFF = Wireless LAN OFF
EXIT
Exit to setting menu
WPS
WPS connection setting
RESET
Reset to factory default
STATUS
Connection status check
To connect the wireless LAN to your home network
The wireless adapter can be connected to your home network using the:
WPS button (Wi-Fi Protected Setup) on the router (if present),
The SSID (Service Set Identifier) and the KEY (password) - located on the unit.
1In the indoor unit setting menu, navigate to the Wireless LAN connection
setting using and . Press to enter the menu.
Indoor unit setting menu Wireless LAN connection setting
5 Operation |
User reference guide
33
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
Timer features
"5.11.2OFF/ON timer operation"[445]
To automatically turn ON or OFF the system.
"5.11.3Weekly timer operation"[447]
To automatically turn ON or OFF the system on a weekly basis.
Special features
"4.4.3Wireless LAN connection"[422]
To operate the unit using smart devices
5.3 Operation mode and temperature setpoint
When. Adjust the system operation mode and set the temperature when you want
to:
Heat up or cool down a room
Blow air in a room without heating or cooling
Decrease the humidity in a room
What. The system operates differently, depending on the user selection.
Setting Description
Automatic The system cools down or heats up a room to the
temperature setpoint. It automatically switches
between cooling and heating if necessary.
Cooling The system cools down a room to the temperature
setpoint.
Heating The system heats up a room to the temperature
setpoint.
Heat boost
This feature is automatic; it quickly heats up your home
when starting up the unit in heating mode.
Fan only The system only controls the airflow (airflow rate and
airflow direction).
During this operation you CANNOT set the temperature.
Drying The system decreases the humidity in the room.
During this operation you CANNOT set the temperature.
Additional info:
Outside temperature. The system's cooling or heating effect decreases when the
outside temperature is too high or too low.
Defrost operation. During heating operation, frost might occur on the outdoor
unit and decrease the heating capacity. In that case, the system automatically
switches to defrosting operation to remove the frost. During defrosting
operation, hot air is NOT blown from the indoor unit.
Humidity sensor. Control the humidity by decreasing the humidity during cooling
process.
5 Operation |
User reference guide
41
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
Powerful operation active Powerful operation disabled
INFORMATION
Powerful operation can be set only when the unit is running; the symbol on
the screen indicates that the function is currently prohibited.
If you press or if you change the operation mode, operation will be cancelled;
disappears from the bottom of the home screen.
5.8 Econo operation
This is a function which enables efficient operation by limiting the maximum power
consumption value. This function is useful for cases in which attention should be
paid to ensure a circuit breaker will not trip when the product runs alongside other
appliances.
INFORMATION
Powerful and Econo operation CANNOT be used at the same time. The last
selected function takes priority.
Econo operation reduces power consumption of the outdoor unit by limiting the
rotation speed of the compressor. If power consumption is already low, Econo
operation will NOT further reduce power consumption.
a
A
B
b
c
d
ARunning current and power consumption
BTime
aMaximum during normal operation
bMaximum during Econo operation
cNormal operation
dEcono operation
The diagram is for illustrative purposes only.
The maximum running current and power consumption of the air conditioner in
Econo operation varies with the connected outdoor unit.
5.8.1 To start/stop Econo operation
1Press to enter the main menu and navigate to the Econo screen using
and .
2Change the setting using and .
5 Operation |
User reference guide
43
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
5.10 Flash Streamer (air cleaning) operation
Streamer generates a high-speed electron stream with a high oxidizing power,
reducing bad odours. Together with the titanium apatite deodorising filter and the
air filters, this function cleans the air in the room.
INFORMATION
The high-speed electrons are generated and go away inside the unit to ensure
safe operation.
The Streamer discharge may generate a fizzing sound.
If the airflow becomes weak, the Streamer discharge may stop temporarily to
prevent ozone smell.
5.10.1 To start/stop Flash Streamer (air cleaning) operation
1Press to enter the main menu. The Flash Streamer screen is on the first
position of the main menu.
2Change the setting using and .
Flash Streamer operation active Flash Streamer operation disabled
3Press to confirm your selection.
Result: active:Flash streamer operation appears on the bottom of the
home screen.
Result: disabled:Flash streamer operation disappears from the bottom of
the home screen.
5.11 Clock and timer setting
1Enter the main menu by pressing and navigate to the clock and timer
setting menu using and . Press to enter the menu.
Clock and timer setting menu
2In this menu, perform the following clock and timer setting. Then press to
return to the main menu or press to exit to the home screen.
Setting list
5.11.1 The clock setting .................................................................................................................................................... 43
5.11.2 OFF/ON timer operation........................................................................................................................................ 45
5.11.3 Weekly timer operation......................................................................................................................................... 47
5.11.1 The clock setting
If the indoor unit's internal clock is NOT set to the correct time, the ON timer, OFF
timer and weekly timer will NOT operate correctly. The clock must be set again:
5 Operation |
User reference guide
48
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
To set Weekly timer operation
1In the clock and timer setting menu, navigate to the weekly timer settings
menu using and .
2Change OFF to ON using and , then press to confirm your selection.
Result: The Daikin eye lights orange. Settings for the first day of the week will
display (4entries for each day).
Weekly timer disabled Weekly timer active
3Navigate between days using and . Navigate between 4entries using
and .
Example:
MON
1/7
1.
2.
Empty field – no setting
for Monday
TUE
2/7
1.
16:50 25.0°c
2.
Unit : on Tuesday atstarts
16:50 with 25°C
temperature setpoint
WED
3/7
1.
8:00 OFF
2.
Unit : on Wednesdaystops
at 8:00
4Press to enter the setting.
5Change the setting to ON, OFF or DEL.
ON timer
TUE
1/4
16:50
25.0°c
ON
The unit starts at set time
and temperature
setpoint.
OFF timer
TUE
1/4
16:50
OFF
The unit stops at set time.
Delete
TUE
1/4
DEL
Deletes this entry
ON/OFF timer
6Go to the hour setting using and change the hour setting using and
in 24-hour format.
7Go to the minutes setting using and change the minutes setting using
and in 10-minute intervals.
8 For OFF timer. Confirm the setting using .
Result: The day of the week with 4 day entries is displayed. The new entry is
present in the entry list. The unit turns ON or OFF at the set time. The entry
list is sorted by time.
9 For ON timer, you can also set the temperature setpoint. Go to the
temperature setting using and change the setpoint using and .
Confirm the setting using .
Result: The day of the week with 4 day entries is displayed. The new entry is
present in the entry list. The unit starts operating with the temperature
setpoint. The entry list is sorted by time.
5 Operation |
User reference guide
50
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
1Set Outdoor unit quiet operation in all rooms using the wireless remote
controls of the units.
2To cancel Outdoor unit quiet operation, you may stop operation in 1 room
using a wireless remote control.
Result: Operation will stop in all rooms. will remain on the display of the
other wireless remote controls.
3To remove the symbol from the other wireless remote controls, stop Outdoor
unit quiet operation in all rooms separately.
Result: The symbol will disappear.
When priority room setting is active
You can select a different operation mode for each room.
Example: Room A has priority, cooling operation mode is selected.
Operation mode in room B, C, D Status of room B, C and D
Cooling, drying or fan only Current operation mode maintained
Heating Standby mode. Operation resumes when room
A stops operating.
Automatic If cooling operation continues. If heating units
enter standby mode. Operation resumes when
room A stops operating.
Priority when using Powerful operation
Example: Room A has priority. Rooms B, C and D are operating.
1Set Powerful operation in room A.
Result: Capacity in room A is increased. Cooling or heating efficiency in rooms B, C
and D may be slightly reduced.
Priority when using Outdoor unit quiet operation
Example: Room A has priority.
1Set Outdoor unit quiet operation on one unit.
Result: All units enter the Outdoor unit quiet operation mode at once.
5.12.2 Night quiet mode
The Night quiet mode requires initial programming during installation. Please
consult your dealer for assistance. This mode reduces the operation noise of the
outdoor unit during the night by reducing the cooling efficiency.
The Night quiet mode is activated automatically when the temperature drops ≥5°C
below the highest temperature recorded that day.
5.12.3 Cooling/heating mode lock in Multi-system
The cooling/heating mode lock can be set via the Multi outdoor unit. Please
consult your authorized dealer for assistance. The cooling/heating mode lock sets
the unit forcibly to either cooling or heating operation. Activate this function if you
wish to set all indoor units connected in a Multi-system to 1 operation mode.
INFORMATION
The Cooling/heating mode lock CANNOT be activated together with the priority room
setting.
7 Maintenance and service |
User reference guide
55
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
NOTICE
Do NOT use gasoline, benzene, thinner, polishing powder or liquid insecticide.
Possible consequence: Discoloration and deformation.
Do NOT use water or air of 40°C or higher. DiscolorationPossible consequence:
and deformation.
Do NOT use polishing compounds.
Do NOT use a scrubbing brush. The surface finishing peelsPossible consequence:
off.
As an end user, you may NEVER clean inside parts of the unit by yourself; this
work must be performed by a qualified service person. Contact your dealer.
1Clean with a soft cloth. If it is difficult to remove stains, use water or a neutral
detergent.
7.3 To clean the front panel
1Clean the front panel with a soft cloth. If it is difficult to remove stains, use
water or a neutral detergent.
7.4 To open the front panel
1Stop operation by .
Result: The front panel closes automatically.
2Open the front panel using the wireless remote control. See "4.4.2 Open the
front panel"[422].
Result: The front panel opens.
3Turn the power supply OFF.
4Pull down both locks on the back of the front panel.
5Open the front panel until the support fits into the fixing tab.
d
c
b
a
aLock (1 on each side)
bBackside of the front panel
cFixing tab
dSupport
7 Maintenance and service |
User reference guide
56
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
INFORMATION
If you CANNOT find the wireless remote control or you use another optional
controller. Pull the front panel carefully up by hand as shown in the following figure.
7.5 About the air filters
Operating the unit with dirty filters means that the filter:
CANNOT deodorise the air,
CANNOT clean the air,
poor heating/cooling,
causes odour.
7.6 To clean the air filters
1Push the tab at the centre of each air filter, then pull it down.
2Pull out the air filters.
12
3Remove the titanium apatite deodorising filter and silver particle filter from
the tabs.
4Wash the air filters with water or clean them with a vacuum cleaner.
5Soak in lukewarm water for about 10 to 15 minutes.
7 Maintenance and service |
User reference guide
57
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
INFORMATION
If the dust does NOT come off easily, wash the air filters with a neutral detergent
diluted in lukewarm water. Dry the air filters in the shade.
Be sure to remove the titanium apatite deodorising and silver particle filters.
It is recommended to clean the air filters every 2 weeks.
7.7 To clean the titanium apatite deodorising filter and the silver
particle filter (Ag-ion filter)
INFORMATION
Clean the filter with water every 6 months.
1Remove titanium apatite deodorising filter and the silver allergen removal air
purifying filter from all 4 claws.
aClaw
2Remove the dust from the filter with a vacuum cleaner.
3Soak the filter for 10 to 15minutes in warm water.
Note: Do NOT remove the filter from the frame.
4After washing, shake off remaining water and dry the filter in the shade. Do
NOT wring out the filter when removing water.
7 Maintenance and service |
User reference guide
59
FTXJ-A(W)(S)(B)9
Daikin room air conditioner
4P518786-20Q – 2024.07
7.10 To remove the front panel
INFORMATION
Remove the front panel only in case it MUST be replaced.
1Open the front panel. See [
"7.4To open the front panel" 455].
2Open the panel locks on the back side of the panel (1on each side).
a
a
aPanel lock
3Push the right arm lightly to the right to disconnect the shaft from the shaft
slot on the right side.
a
c
b
aArm
bShaft slot
cShaft
4Disconnect the front panel shaft from the shaft slot on the left side.
a
cb
aArm
bShaft slot
cShaft
5Remove the front panel.
6To re-install the front panel, perform the steps in the opposite order.
7.11 To take following items into account before a long idle period
Operate the unit several hours in mode to dry the inside of the unit.fan only


Produkt Specifikationer

Mærke: Daikin
Kategori: Ikke kategoriseret
Model: FTXJ35A2V1BB9

Har du brug for hjælp?

Hvis du har brug for hjælp til Daikin FTXJ35A2V1BB9 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Daikin Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer