Daitsu HOLLY CADR 65 Manual

Daitsu Luftrenser HOLLY CADR 65

Læs nedenfor 📖 manual på dansk for Daitsu HOLLY CADR 65 (120 sider) i kategorien Luftrenser. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/120
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.
If you have lost the Owner’s Manual, please contact the local agent or visit
sat.eurofredgroup.com.
Split Air Conditioner
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervi-
sion or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible harm to the environment or human
health from uncontrolled waste disposal, recycle it responsibly to promote the sustaina-
ble reuse of material resources. To return your used device, please use the return and
collection systems or contact the retailer where the product was purchased. They can
take this product for environmental safe recycling.
R410A(R32/125: 50/50):
Content
Operation Notices
Precautions...........................................................................................................1
Parts Name...........................................................................................................6
ScreenOperation Guide
.......................................................................7
Emergency operation 1 ......................................................................................... 1
Maintenance
Clean and Maintenance......................................................................................11
Malfunction
Malfunction analysis 1 ........................................................................................... 5
2087.5
Remote control operation ............
5
Precautions
WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Working temperature range
Indoor side DB/WB (°C) Outdoor side DB/WB (°C)
Maximum cooling 32/23 43/26
Maximum heating 27/- 24/18
NOTICE:
The operating temperature range (outdoor temperature) for cooling is -15ºC~43ºC;
Heating temperature range for the model without electric heating belt for chassis
is -15ºC~24ºC Heating temperature range for the model with electric heating belt
for chassis is -20ºC~24ºC.
6
Parts Name
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
(Display content or position may be different from
above graphics, please refer to actual products)
air inlet
panel
lter
aux.button
horizontal louver
air outlet
cooling
indicator
power
indicator
receiver
window
display
heating
indicator
temp.
indicator
drying
indicator
Indoor Unit
17
Malfunction analysis
Phenomenon Check items Solution
Odours are
emitted
Whether there’s odour
source, such as furniture and
cigarette, etc.
Eliminate the odour source.
Clean the filter.
Air condition-
er operates
normally
suddenly
Whether there’s interference,
such as thunder, wireless
devices, etc.
Disconnect power, put back
power, and then turn on the
unit again.
Outdoor unit
has vapor
Heating mode is turned on? During defrosting under
heating mode, it may
generate vapor, which is a
normal phenomenon.
“Water ow-
ing” noise
Air conditioner is turned on or
turned off just now?
The noise is the sound of
refrigerant flowing inside
the unit, which is a normal
phenomenon.
Cracking
noise
Air conditioner is turned on or
turned off just now?
This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.