Delta Dore Tyxia RF 642 Manual

Delta Dore Modtager Tyxia RF 642

Læs nedenfor 📖 manual på dansk for Delta Dore Tyxia RF 642 (2 sider) i kategorien Modtager. Denne guide var nyttig for 21 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
• Carefully read these instructions prior to installation.
The unit must be installed in compliance with
current standards.
• Always switch off the mains before installing or
servicing the unit.
• Do not attempt to repair the unit yourself;
an after-sales service is available.
• Check that the fastenings are suited to the surface
to which the unit will be attached (plasterboard,
brick, etc.).
The diagrams provided are simplified for greater
clarity. Protections and other accessories required
by standards are not illustrated.
Standard and good practice must be complied with.
Connected or nearby equipment must not generate
excessive interference (directive 2014/30/EU).
www.deltadore.com
TYXIA RF 642
Wireless receiver - 1 channel
Presentation
1
Mounting
3
Connection to the heating
4
Pulse mode (remote control switch, garage door, electric gate)
7
Associating the receiver with a
transmitter thermostat
5
Associating the receiver with a
door/window opening detector
6
Location
2
TYXIA RF 642 may be used for two types of
application:
- Control of automatic devices: lighting, a garage
door or an electric gate,
- Heating control: associated with a transmitter
thermostat, it can be connected to a boiler or
used to control an electric heating system (via a
contactor).
Removing the cover
To remove the cover, push the
tab and lift the cover.
Attachment with screws
Mounted on a wall using the screws
and plugs supplied.
Connecting a boiler with thermostat input
Connect receiver terminals 3 and
4 to both terminals of the boiler
thermostat input.
If necessary, remove the shunt (electric wire)
connecting the two thermostat input terminals.
Connection
Operation on the TYXIA RF 642
Pressing the button on the receiver changes the
current state (on or off).
Operation with an associated TYXIA or
TYDOM transmitter
On the receiver, press the button until the LED
flashes (~3 seconds).
You now have two options.
Slow flashing: simple lighting mode
Quick flashing: pulse mode
Press the receiver button briefly to switch from
one rate of flashing to the other.
Select the quick flashing option.
On the transmitter, press and hold the o button
down for 5 seconds.
The button will light up, go out then light up again.
Release.
Check that the receiver’s LED is no longer flashing.
The transmitter o button is associated with
the receiver in pulse mode.
Mounting by double-sided
adhesive tape
Mounted on a wall using the
double-sided adhesive tape supplied.
Ensure that the surface on which the
tape is applied is thoroughly clean
before mounting.
Connection
To connect the control wires,
run the wires along the raceway
provided or by piercing the hole at .Ê
Refer to the section that deals
with your type of installation.
When the connection is made,
fit the cover and switch on the
current at the circuit breaker.
Connecting a boiler
without thermostat input
If the boiler does not have
a thermostat input, you can
directly control the circulator
located next to the boiler.
To control electric convectors, you MUST use
a power contact switch that
is suitable for the total power
to be controlled.
The receiver must be placed near the automated de-
vice control (electrical switchboard) or heating control
(burner or thermostat input for a boiler, electrical
switchboard when used with a contact switch).
To avoid interference with the radio transmission,
the antenna must be free from any metallic elements
(cables, electrical switchboard, metallic covers).
The receiver power supply must be provided through
an electrical cable connected to the 230 V mains.
Antenna
Button
Removable
cover
LED
1
2
1
Because of changes in standards and equipment, the characteristics given in the
text and the illustrations in this document are not binding unless confirmed by our
services.
N
L
230V
On the receiver, press the button until the LED
flashes (~3 seconds).
Put the transmitter into association mode
(see transmitter guide).
Check that the receiver LED is no longer flashing.
The receiver is associated with the transmitter.
When associated with the receiver, a door/window
opening detector can prompt the heating to switch
automatically to frost protection whenever a window
is opened, for example.
On the receiver, press the button until the LED
flashes (~3 seconds).
On the door/window opening detector, press the test
button.
Check that the receiver LED is no longer flashing.
The door/window opening detector is associated with
the receiver.
230V
Example of a boiler
terminal box
Boiler
Circulator Power supply
230V/50Hz
N
N
L
L
230V
N
Power supply
230V/50Hz
Convector(s)
Convector(s)
Power supply of the
contact switch coilr OR
Direct convector control
if power < 3000 W
contact switch (not
supplied) fitted in the
electrical switchboard
If the boiler has a clock input,
do not mistake it for the
thermostat input.
Remove the
shunt
Wires to be
connected to the
receiver
Entrée
thermostat
de la chaudière
IMPORTANT: To use the receiver in pulse mode, it
must be associated with a transmitter.
Power supply
230V
Remote
switch Control of an
opening (for
example : a gate
Le mode impulsionnel ne peut être commandé
qu’avec une touche o (TYXIA).
OU
(modification de l’état en cours)


Produkt Specifikationer

Mærke: Delta Dore
Kategori: Modtager
Model: Tyxia RF 642

Har du brug for hjælp?

Hvis du har brug for hjælp til Delta Dore Tyxia RF 642 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Modtager Delta Dore Manualer

Modtager Manualer

Nyeste Modtager Manualer

Onkyo

Onkyo TX-RZ30 Manual

23 November 2024
Sony

Sony STR-DE185 Manual

23 November 2024
QSC

QSC PowerLight 9.0 Manual

20 November 2024
Ashly

Ashly FX-125.4 Manual

20 November 2024
Harman Kardon

Harman Kardon CA5250 Manual

19 November 2024
Esoteric

Esoteric F-05 Manual

19 November 2024
Konig & Meyer

Konig & Meyer 28075 Manual

18 November 2024
IFi Audio

IFi Audio ZEN CAN 3 Manual

18 November 2024