Smoke detector
Art. no. 32-1988, 32-3381, 32-3382,
32-3383
Placing of smoke
detector
Do not put asmoke detector in the
following places
• Do not place asmoke detector in akitchen
with poor ventilation. Smoke and fumes from
thepreparation of food and baking can trigger
thealarm.
• Do not place smoke detector near fans or
ventilation conduits. Smoke could drift in their
direction instead of toward thesmoke detector.
• Do not place asmoke detector in agarage.
A cars exhaust may trigger analarm.
• Do not place asmoke detector in very damp
spaces or aspace exposed to broad temperature
variations. A smoke detector should not be placed
in anarea where thetemperature is below 5 °C or
above 40 °C.
A smoke detector should not be painted.
Assembly
Test and care
1. Test thesmoke detector at least once every
month, and preferably once per week, e.g.,
when you house clean.
2. Always test thesmoke detector after returning
from holidays or after being away for aprolonged
period. The smoke detector can be tested with
thetest button or by blowing alittle smoke
toward thesmoke detector.
3. The smoke detector sounds as long as thetest
button is pressed down or as long as there is
smoke in it.
4. Make sure thebattery is correctly positioned. Replace
battery if thesmoke detector makes no noise.
5. Below thetest button is ared diode that blinks
1–2 times per minute. It shows that thesmoke
detector is working.
6. Wipe thesurface of thesmoke detector with
amoist cloth when needed. When cleaning
house, thesmoke detector may be vacuumed
slightly as you do house cleaning.
Switching off thealarm sound
(model 32-3383)
When asmoke detector is placed in, say, akitchen
thealarm may be sometimes set off unintentionally.
The alarm sound can then be shut off for about ten
minutes by pressing on thetest button. Two signals
are heard when thesmoke detector returns again to
its normal state.
Changing batteries
A battery lasts for about one year. About one month
before thebattery is completely discharged, thesmoke
detector will start to emit short signals at about
one-half minute intervals. It is then time to replace
thebattery. Once this is done thedetector will start
working again.
Battery: 9 V standard or alkaline battery, e.g.,
Duracell MN 1604, Eveready no. 522, 1222 or 216,
Gold Peak 1604 P.
Always test smoke thedetector after replacing
thebattery.
Full
battery
When
sound
heard
Replace
battery
Control
lamp
Blinks
1–2 times/
min
Blinks
without
interrup-
tion
Alarm signal +
blinks once per
minute
Alarm
signal
Interrupted
signal
Alarm
signal
Blinks + Alarm
signal once/min
Guarantee
The smoke detector has a5-year guarantee
calculated from day of delivery. The guarantee covers
material and manufacturing flaws and is limited to
new for old or repairs. The guarantee is valid provided
only that theinstructions are followed. Return
adefective smoke detector to vendor or importer
(address below) with indication of defect and battery.
Announcement from (Finnish)
Radiation Safety Centre
(Does not apply to optical smoke detector model
32-3382).
This smoke detector contains asmall amount of
radioactive substance – americium 241.
The Finnish Radiation Safety Centre has investigated
and approved theradiation safety of this type of
smoke detector. In said test, normal use of thesmoke
detector does not expose humans to doses harmful
to thehealth.
Normal use entails:
• Correct choice of where to place thedetector.
• Smoke detector is used in frequented places.
• Proper care of smoke detector, e.g., instructions
for replacing battery and for cleaning are followed.
• The smoke detector must not be used by
children. The smoke detector may be disposed of
with thehousehold rubbish.
• The approval number of theFinnish Radiation
Safety Centre and theimporters address are on
thelabel on thesmoke detector.
Bedroom Bedroom
Bedroom
Bedroom
Bedroom
Cellar
Place in ceiling 50 cm
from wall
On wall 15–20 cm
from ceiling
• The smoke detector should bee placed in
theceiling near bedrooms
• If thebedrooms are in different parts of
thedwelling, asmoke detector should be placed
in each room.
• In abuilding with several flats there should be
asmoke detector in every flat.
• Make sure thesound from thesmoke detector is
distinctly heard.
• The earlier your family is warned thegreater
thechance of saving family members and
salvaging property.
1. Remove
thebottom plate
by turning it
slightly.
2. Insert battery
and attach
theconnecting
wires.
3. Press thetest
button and hold
down afew
seconds to test
thealarm sound.
4. Next check that thered light diode is blinking afew
times per minute.
5. Attach thebottom plate to theceiling with
theenclosed screws. Then screw thesmoke
detector tightly to thebottom plate.
Connecting function
Pull cable (e.g. oval wire SKF 2×0.75 mm²) between
thesmoke detectors that shall be connected.
The smoke detectors should be connected in parallel.


Produkt Specifikationer

Mærke: Deltronic
Kategori: Røgdetektor
Model: S-1201

Har du brug for hjælp?

Hvis du har brug for hjælp til Deltronic S-1201 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Røgdetektor Deltronic Manualer

Deltronic

Deltronic FHB-150 Manual

29 August 2024
Deltronic

Deltronic S-1201 Manual

28 August 2024
Deltronic

Deltronic 10401 Manual

28 August 2024

Røgdetektor Manualer

Nyeste Røgdetektor Manualer

First Alert

First Alert HD6135FB Manual

14 Oktober 2024
Elro

Elro FS151021M Manual

8 Oktober 2024
Elro

Elro 2001-023 Manual

3 Oktober 2024
FireHawk

FireHawk FHB10 Manual

2 Oktober 2024
First Alert

First Alert SA410 Manual

1 Oktober 2024
König

König SAS-SA2002 Manual

1 Oktober 2024
FireAngel

FireAngel ST-622 Manual

30 September 2024
Alecto

Alecto SA-49/1 Manual

29 September 2024