DPA D:screet 60 Manual

DPA Mikrofon D:screet 60

Læs nedenfor 📖 manual på dansk for DPA D:screet 60 (2 sider) i kategorien Mikrofon. Denne guide var nyttig for 18 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Introduction
The DPA d:screet™ Miniature Microphones are designed for
use with wired or wireless systems in theater, film, television,
conferences and instrument close-miking applications.
To ensure optimal performance of your d:screet™ Miniature
Microphone, please follow the simple care and maintenance
instructions below. Our d:screet Miniature Microphones are
designed to be resistant to humidity and moisture. Highly resist-
ant materials like gold plated stainless steel, and features like the
double-vent protection system, ensures that you avoid damage
by fluids. Keep your d:screet Miniature Mics away from water
and cleaning fluids, and keep the microphone element dry at all
times.
Cleaning guide
The cable and protection grid are the only parts that may be
cleaned. Do not use any kind of cleaning fluid other than demin-
eralized water. Avoid all kinds of spray or uids containing chemi-
cal components to remove static electricity on or close to the
microphone as this could cause damage to the electret layer.
When mounting a d:screet Miniature Microphone directly on or
close to the skin of a performer, care should be taken to avoid
sweat from running into the microphone. If the microphone has
been exposed to sweat, it must be rinsed out in demineralized
water and left to dry out to recover its original specifications.
Drying out the microphone between exposures to humidity will
also help to extend its lifetime. If the microphone gets lled up
with water it will not be damaged, but possibly turn deaf while
the water is captured inside the microphone, behind the pro-
tection grid. Remove the water by shaking the microphone or
drying it with a piece of lint free cloth.
Cleaning the microphone grid
During use in environments where the microphone is exposed to
makeup or dusty materials, the grid may get clogged up. Remove
the microphone grid from the microphone element (not applicable
to SC4071, SCO71-H and 4080) and clean the grid using a soft
cloth and demineralized water only. Make sure the grid is dry before
re-mounting it on the microphone housing. For SC4071, SCO71-H
and 4080 (which do not feature removable grids) cleaning the grid
is done using a soft cloth and demineralized water.
Cleaning the microphone cable
Residue from tape, glue, or makeup on the cable must be re-
moved after use. Leaving these substances on the cable over
longer periods of time may etch into the cable jacket and will
make the cable more susceptible to breaks. The cable can easily
be cleaned using organic oil (e.g. olive oil) or lukewarm, dem-
ineralized water. Do not bend the cable or rub it harshly since
this may stress the inner cores of the cable and cause them to
break over time.
Microphone grids
The d:screet Miniature Microphones (SC4060/61/62/63 and
SCO60/61-H) are supplied with two dierent grids for acoustic
equalization, depending on the placement on the performer; a
soft boost grid (pre-fitted) giving a 3 dB soft boost at 8-20 kHz.
Alternatively, the high boost grid for chest mounting gives ap-
proximately 10 dB boost at 12 kHz. Without any grid mounted,
the microphone is linear, but unprotected against dirt.
The d:screet Miniature Microphones with presence boost
(SC4071 and SCO71-H) and the 4080 have a fixed presence
boost grid. These types are pre-equalized to provide optimal
speech intelligibility when using chest placement.
Mounting
Several mounting accessories are specially designed to mount,
place or conceal the d:screet Miniature Microphones. Refer to
www.dpamicrophones.com/dscreet for an up-to-date selection
and overview.
d:screetTM 4080
Special for the 4080 is that it is delivered with a pre-mounted pop-
filter in a holder with an integrated shock mount, fixed on the
DPA clip (fig. 1). The 4080 is designed to be always used in this
setup. When mounting the holder on to the clip, a small loop of
1.5 cm (0.6 in) (fig. 2) should be left between the microphone and
the holder. Press the cable gently into the cable trail and secure the
cable with the cable clamp (fig. 3). To ensure the optimal sound of
the 4080, the best position on the performers body is 20 - 25 cm
(8 10 in) from the speaker’s mouth (fig. 4). With its innovative
mounting solution it can easily be turned in all directions, upwards
and sidewards, to get the best sound. Furthermore, it ensures that
the 4080 fits both left and right buttoned shirts.
Microphone element
The diaphragm in the microphone element is the most sensi-
tive part of the unit, and must be left untouched to preserve its
original characteristics. Do not spray any substances such as hair
spray directly into the microphone and avoid getting makeup or
paint on the microphone element and housing.
Correct treatment of the microphone cable
The cable is usually longer than required for its actual purpose.
Make sure that superfluous cable is wound up in soft loops (pref-
erably 6 – 8 cm (2.4 3 in) in diameter). Avoid kinks in the cable.
Handling noise from the cable can be reduced significantly by
making a loose cable loop, as close to the microphone element
as possible.
Correct use of adapters and MicroDot connectors
To provide users with safe and compact mounting of connec-
tors, all our d:screet Miniature Microphones are fitted with the
MicroDot connector. A broad range of adapters is oered as
optional accessories for most wireless systems for professional
use. Never attempt to loosen or tighten the connector by the
cable or its strain relief. Some wireless systems require the use
of electronic components inside the adapter to optimize the
signal level, the DC-oset filtering, and powering of the built-in
microphone preamplifier.
Always use the adapters from DPA Microphones with the wire-
less systems to ensure the correct electronic circuit. Do not use
non-standard adapters or connectors as you might damage the
microphone preamplifier.
w w w . d p a m i c r o p h o n e s . c o m
Learn more at www.dpamicrophones.com
Fig. 1. 4080 Miniature Cardioid Microphone, Lavalier
Fig. 3. Securing the cable with the cable clamp on 4080
Fig. 4. Place 4080 20-25 cm from mouth Fig. 7. SCO60-H Heavy Duty in SCM0001 Miniature Clip(8 – 10 in)
Fig. 5. 2 x SC4071 in SCM0008 Miniature Clip Fig. 8. SC4060 in SCM0004 Miniature Clip, Small
Fig. 6. SC4060 in SCM0017 Miniature Mic Holder
Fig. 2. Loop between holder and clip on 4080


Produkt Specifikationer

Mærke: DPA
Kategori: Mikrofon
Model: D:screet 60

Har du brug for hjælp?

Hvis du har brug for hjælp til DPA D:screet 60 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Mikrofon DPA Manualer

DPA

DPA 6061 Manual

14 September 2024
DPA

DPA d:screet 4061 Manual

9 September 2024
DPA

DPA 4017C Manual

4 September 2024
DPA

DPA 4017B Manual

4 September 2024
DPA

DPA 4017ES Manual

4 September 2024
DPA

DPA 2017 Manual

28 August 2024
DPA

DPA 4560 CORE Manual

31 Juli 2024
DPA

DPA D:screet 60 Manual

29 Juli 2024
DPA

DPA 2028 Manual

29 Juli 2024

Mikrofon Manualer

Nyeste Mikrofon Manualer

Audibax

Audibax AWM 403 TD Manual

4 November 2024
Audibax

Audibax AWM 202 Manual

3 November 2024
Audibax

Audibax Oslo 1600 Manual

3 November 2024
Audibax

Audibax Berlin 1800 Manual

3 November 2024
Audibax

Audibax Dublin 3000 Manual

2 November 2024
Audibax

Audibax Mic 900 Manual

2 November 2024
Audibax

Audibax AWM 402 Manual

2 November 2024
Audibax

Audibax AWM 404 TD Manual

2 November 2024
Audibax

Audibax IEW 600 Manual

2 November 2024