©2014 Tyco S ecurity Products, Toronto, Canada www.dsc.com Tech. Support: 1-800-387-3630
PG9944/8944/4944 Installation
Instructions
W ireless Outdoor PIR Detector with C amera
Overview
The PGx9 44 use s eight PIR sensors, each actin g a s a
Quad detector to accurately and reliably determine
whether an alarm is justified . Features & benefits
include:
lOptimum performance even in poor weather con-
ditions such as snow, rain, dust, wind and direct
sunlight.
lTamper protection prevents opening and removal
from wall.
lBuilt-in link quality indicators reduce installation
time by eliminating the need for the installer to
physically approach the control panel.
lMicroprocessor-controlled compensation.
lImmunity to pets weighing up to 18 Kg (40lb).
NOTE: Pet immunity feature has not been evaluated
to UL 639 or ULC-S306-03 due to the feature not
being addressed in either standard.
CAMERA FEATU RES
lColor or black & white images
lAuto-setup for brightness and contrast via the con-
trol panel
lDay and night CMOS camera, with IR illumination.
This allows taking pictures in full darkness
lCamera range of 12m (40ft); with IR illumination
10m (33ft)
lCamera operation modes:
lPost alarm – pictures are taken after detec-
tion by detector.
lVisual Verification
Device Setup
WARNING! To comply with FCC and IC RF exposure
compliance requirements, the PIR detector should be
located at a distance of at least 20 cm from all persons
during normal operation. The antennas used for this
product must not be co-located or operated in con-
junction with any other antenna or transmitter.
NOTE: The PG Series wireless PIR Motion detectors
shall be installed and used within an environment that
provides the pollution degree max 2 and overvoltages
category II in NON HAZARDOUS LOCATIONS.
The equipment is designed to be installed only by qual-
ified service persons.
NOTE: To ensure the continued op eration of all wire-
less devices after performing a system default, a
global upload of all wireless programmin g via DLS is
recommended before defaulting the system. After
completing the sy stem default, download the wireless
programming.
NOTE: Back tamper switch is req uired for UL com-
mercial b urglary installations.
BA TTERY INSTALLA TI ON
Initial battery installation should be done on a flat sur-
face. After inserting the batteries, the LED flashes for
60 seconds and the detector enters a 15 minute local
diagnostic mode.
NOTE: W h en manually programming wireless
devices, if a devic e has been pow ered up for more
than 48 hours it cannot be enrolled into the system
until the device has been tampered and restored.
When programming the panel using Quick Enroll, fol-
low the steps detailed in "Enrollment."
NOTE: A fter restoring a low battery trouble the sys-
tem may take up to 5 minutes to clear the trouble.
EN ROLLMENT
To quick enroll:
1. On a keypad press [*] [8] [Installer Code] [804]
[000].
2. Press and hold the device enroll button until the
LED lights steady and then release the enroll but-
ton while the LED is still lit. A confirmation mes-
sage then appears on the keypad.
3. Press [*] key to confirm ID.
4. Enter [3 digit zone #].
5. Enter [3 digit zone type].
6. Enter [1 digit partition #] for all desired partitions
and press [#]. If using an LCD keypad you can
scroll to the desired partitions and press [*] to
toggle the partition.
7. On an LCD keypad enter the label by using word
library.
To pre-enroll:
1. Remotely configure the unique ID number into the
system. For more information see the HSM2HOST
manual.
2. When on-site, press the device enroll button.
NOTE: If the wireless device has been powered for
more than 48 hours without b eing e nrolled, tampe r
and restore the dev ice to enroll it.
PLACEMENT AND W ALK TES TI NG
Before permanently mounting any wireless device,
temporarily mount the device and perform a Place-
ment test. Perform a walk test of the coverage area at
least once a year to ensure that the detector is work-
ing correctly.
1. Tamper the device by removing the cover.
2. Restore the tamper. The device
now enters Placement test
mode for 15 minutes.
3. Trip the device and the red
LED blinks once to identify
that a signal is being sent to the
receiver and then blinks three
times to identify the signal
strength. To perform a walk
test, walk across the far end of
coverage pattern in both dir-
ections. The following table indicates received sig-
nal strength indication.
LED Res ponse Signal Strength
Green LED bl ink s STRONG
Orange LED blinks GOOD
Red LED bli nks POOR
No blinks No communication
IMPORTANT! Only GOOD or STRONG signal
stren gths are acceptable. If you receive a POOR sig-
nal from the device, re-locate it and re- test until a
GOOD or STRONG signal is received.
NOTE: For UL/ULC insta llations, only ST RONG sig-
nal levels are acceptable. After installation v erify the
product functionality in conjunction with the com-
patible receivers HSM2HOST9, HS2LCDRF(P) 9,
HS2ICNRF(P) 9 and PG9920.
NOTE: For detailed Placement instructions refer to
the control panel Reference Manual.
MOUNTI NG THE D EVI CE
Installation Notes: The top cover should only be
accessed by authorized service personn el or man-
ufacturer. Do not obscure the detector field of view
with large objects. Install in position such that expec -
ted intruder motion is perpendicular to the zones o f
detection.
Alarms triggered by conditions such as weather, blow-
ing leav es and b rush, or related environmental con-
ditions, etc., need to be considered wh en asse ssing the
installation and application. If nuisance trips are not
tolerable it is recommended that the wireless outdoor
intrusion detection unit is enrolled in the system to a
zone that is defined as a trouble alarm circuit.
1. Fix the bracket firmly on a stable wall or pillar.
The orientation of the fixed bracket must be as par-
allel as possible to the surveyed ground surface.
2. Mark drilling point
3. Drill
4. Fasten with three long screws
5. Fasten the detector to the bracket with two short
screws.
Adjust the detector's horizontal and
vertical angles according to the
surveyed ground surface. The ver-
tical angle indicator position for
various installation height and cov-
erage distance combinations is
detailed in the following table (the
information refers to a relatively
flat surveyed area. Verify the ver-
tical adjustment by walk-test).
Mounting Height
Coverage Distance
2m
6.7 ft
4m
13 ft
6m
20 ft
8m
26 ft
10m
33 ft
12m
39 ft
3.0m/ 10 ft - 1 2 2 3 3
2.5m/ 8 ft 1 1 2 3 4 4
2.0m/ 7 ft 1 2 3 4 5 5
1.5m/ 5 ft 2 3 4 5 - -
LED Operation
LED Indic ations Event
Red LED blinks Stabilization (warm-up 60 sec.)
Red LED on 0.2
sec. Tamper open/close
Red LED 2 blinks One quad PIR detection in dia-
gnostic mode
Red LED on 2 sec. Intruder alarm
Configuration
To enter the wireless configuration section enter
[804][Zone Number].
DEVI CE TOGGLE
[001][01] Alarm LED - Defaul t [Y]
Enables the devices LED to
activate when an alarm event
occurs .
[001][04] Supervision - Default [Y]
Enables s upervision of the
device.
[001][09] More Options
[03] 24Hr/Ni ght - Default [Y]
Define i f motion alarms are
always enabled or only
enabled at night. For UL/ULC
installations night mode is to
used to s upplement the pro-
tecti on covering the detec-
tion area.
DEVI CE OPTI ONS
[003] Hightraffic Shutdown - Default [01]
Activating this feature helps conserve battery
power when the s ystem is disarmed by c on-
figuring a reporting timer. When motion is
detected, the device transmits an alarm to the
rec eiv er and will not report any further events
until the timer ex pires. Any moti on detected
duri ng the configured period wi ll be reported
once the timer ex pires. No Delay causes the
device to report an alarm each time the
detector is tri pped.
[01] Detector
Disabled
(whil e dis-
armed)
[02] No Delay [03] 5 second
delay
[04] 15
second delay
[05] 30
second delay [06] 1m delay
[07] 5m delay [08] 10m
delay [09] 20m delay
[10] 60m
delay
[004] Image Brightness - Default [04]
Lightens and darkens the image
[01] Image
Bright
-3
[02] Image
Bright
-2
[03] Image
Bright
-1
[04] Image
Bright
0
[05] Image
Bright
+1
[06] Image
Bright
+2
[07] Image
Bright
+3
[005] Image Contrast - Default [04]
Lightens and darkens the contrast.
[01] Image
Contrast
-3
[02] Image
Contrast
-2
[03] Image
Contrast
-1
[04] Image
Contrast
0
[05] Image
Contrast
+1
[06] Image
Contrast
+2
[07] Image
Contrast
+3
[007] Detection Sensitivity - Default [02]
Selects the sensitivity range of PIR devices.
[01] Low Sens-
itivity
[02] Mid Sens -
itivity
[03] High
Sensitivity
[04] UL Stand-
ard
[011] Camera Toggles
[01] Color -
Default [Y]
[02] High Res.
- Default [Y]
[03] Normal
Res. - Default
[N]
[09] More
Options
[09][01] AC
Power -
Default [N]
SPECIFICATIONS
Caution! Risk of explosion if b attery is replaced by
an incorrect type. Dispo se o f used batteries according
to the manufacturer's instructions and according to
loc al rule s and regulations. Batteries a re to be
replaced by service persons only.
OPTICAL
Black Mir ro r Max . Cover age: At least 12 m (40 ft) /
90°
Detector Technology: 8 indep endent quad PIR detect-
ors operating in true Quad configuration
Pet Immunity: Up to 18 Kg (40 lb)
ELECTRICAL
Input Power: Two 3 V CR1745 0 Lithium batterie s
Note: For UL installations use Eve Energy Co.
CR17450 3V only.
Battery Life (fo r typical use): minimum one year, typ-
ica l 3 ye ars (not ver ified by UL/U LC)
Low Battery Threshold: 4.0 V
Functional
Picture Resolution: 320x2 40 pixels QVGA
Frame Rate: up to 2 fps (for user)
Alarm period: 2 seconds
WIRELESS
Frequency Band (MHz): CE Listed PG4944:
433MHz; CE/EN listed PG8944: 868MHz ;
FCC/IC/UL/ULC liste d PG9944: 912 -91 9MHz
MOUNTING
Mounting type: Wall mounting
Mounting Height: 1.5 3.0 m (5 10 ft). Must be 8
feet for UL/ULC listed installations.
Horizontal Adjustment: -45° to +45°, in 5° steps
VerticalAdjustment: 0° to -10°, in 2.5 ° steps
ENVIRONMENTAL
Temperature range: - 40ºC to + 70ºC (UL /ULC only
verified the range - 35ºC to +66ºC)
Relative Humidity: up to max. 93%RH, non-con-
densing
White Light Immunity: Above 25000 lux
PHYSICAL
Size (H x L x W): 157 x 147 x 124 mm (6-3/16 x 5-
13/16 x 4- 7/8”)
W eight ( with ba tte ry): 6 00 g (21 oz)
COMPATIBLE RECEIVERS
433MHz Band: HSM2HOST4; HS2LCDRF(P)
4;HS2ICNRF(P)4 ; PG4920
868MHz Band: HSM2HOST8; HS2LCDRF(P)8;
HS2ICNRF(P) 8;PG8920
912-919MHz Band: HSM2HOST9; HS2LCDRF(P)9;
HS2ICNRF(P) 9; PG9920
NOTE: Only devices operating in band 912-91 9MHz
are UL/ULC listed.
Notice
The PGx9 44 detector was designed to adhere to
applicable privacy re gulations and only processes
data needed for the prima ry func tionality of the
device. Before using the detector you will be ask ed to
provide consent with processing of the personal d ata
that the detector may capture. No te that the detector
record s video to secure the best functionality of the
device. The recordings are processed securely and
automatically erased on a periodic basis. Based on the
location of the module you may have the obligation to
issue a notice about using it.
The data recorded through the PGx9 44 detector are
processed and maintained primarily by the data con-
troller. Data controller is the entity that provides mon-
itoring services to you. You have the right to enquire
about your data with them. For more information
about their privacy practices please contact the data
controller.
For more information about Tyco privacy practices
please visit our website http://www.tyco.com/privacy.
UL/ULC No t e s
Only model PG9944operat ing in thefr equenc yband 912-919MH z is UL/ ULC listed. ThePG9944 has
beenlisted by UL for com mer cialandresidentialburglary applications andbyU LC for residential
burglaryapplications in accordance with ther equirements in theStandardsU L639 and ULC- S306
for I ntr usion D etectionUnits.


Produkt Specifikationer

Mærke: DSC
Kategori: Overvågningskamera
Model: PG9944

Har du brug for hjælp?

Hvis du har brug for hjælp til DSC PG9944 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Overvågningskamera DSC Manualer

DSC

DSC PG9905 Manual

2 September 2024
DSC

DSC PG9914 Manual

2 September 2024
DSC

DSC HS2TCHP Manual

2 September 2024
DSC

DSC HS2064 Manual

2 September 2024
DSC

DSC PG9944 Manual

25 Juli 2024

Overvågningskamera Manualer

Nyeste Overvågningskamera Manualer