1.Introduction
1.1 Key Characteristics
1.2 Pulse output
1.3 RS485 Serial – Modbus RTU
1.4 Mbus for SDM230-Mbus
User Manual V1.6
SDM230 Series
Single Phase Two Wire Multifunction Din Rail Meter
.
T h e b i- di re c t i o n al m ea su re me nt m ak e s t h e m e t e r
s u i t a bl e f o r a ct iv e a n d r e ac t iv e e n e r gy a n d p o w er
mon itor ing app licatio ns, and al so pe rf ec t f or s ol ar PV
me as ur emen ts . Wit h RS 48 5 M od bu s an d M -b us p or t,
the me ter is eas y to remo te co mmun ic at io n wit h ot he r
AMR/SCADA systems.
·Bi-directional measure and display
·Multi-function measurements
·Two Pulse outputs
·RS485 Modbus / M-bus
·100A direct connection
·Two module size (35mm)
·Password protected set-up
·Backlighted LCD
·2 tariff dual power source
The meter provides two pulse outputs. Both pulse outputs
are passive type.
Pulse output 1 can be set to generate pulses to represent
total / import/export kWh or kVArh.
The pulse constant can be set to generate 1 pulse per:
0.001/0.01/0.1/1kWh/kVArh (default is 0.001 export kWh).
Pulse width: 200/100/60ms
Pulse output 2 is non-configurable. It is fixed up with active
kWh (Imp). The constant is 1000imp/kWh.
RS485 serial port with Modbus RTU protoco l to provide
a me ans o f r em ot el y m on ito ri ng a nd c on t r oll ing t h e
Uni t . Se t- up s cr e e ns a re p ro vi d e d f o r se t ti ng up th e
RS485 port.
This unit has an M-BUS serial port with M-BUS protocol
to provide a means of remotely monitoring and controlling
the unit set-up screens are p rovi ded for se tti ng up the
M-bus port.
1.5 2T by time relay for SDM230-2T
The unit has a time relay inside which can monitor if there
is external 230V signal input. If there is 230V signal inp ut,
the meter switches Tariff 2 measurement, otherwise it will
measure as Tariff 1.
2.Operation
2.1 LCD Display
Model Measurements Pulse Outputs Multi
Tariffs
SDM230-
Modbus
U, I, P, Q, S , PF, Hz,
Dmd, kWh, kVArh,
Import, Export
RS485
Modbus
1:
congurable
2:
1000imp/kwh
NO
SDM230-
2T
1:
congurable
2:
1000imp/kwh
U, I, P, Q, S , PF, Hz,
Dmd, kWh, kVArh,
Import, Export
SDM230-
Mbus
U, I, P, Q, S , PF, Hz,
Dmd, kWh, kVArh,
Import, Export
M-bus
EN13757-3
1:
congurable
2:
1000imp/kwh
NO
Communi-
cation
1
1
1
11
2
2
2
22 3
3
3
33 4
4
4
44 5
5
5
55 6
6
6
66
7
7
7
77
8
8
8
88
9
9
9
99
1
1
1
110
0
0
00
11
11
11
1111
1
1
1
112
2
2
22
1
1
1
113
3
3
33
2 Tariffs
(time relay)
RS485
Modbus
10 Import(input)reactive energy
Example: 5.00kVArh
11 Export(output)reactive energy
Example: 5.00kVArh
9
T2 reactive energy
Example: 2.00kVArh
(for SDM230-2T only)
The setting is done correctly
The entering information is
wrong. The operation fails.
12 Resettable total energy
Warnings
Im p or ta nt S af e ty In fo rma ti o n i s con t ai n ed in th e
Maint enance sect ion. Famili arize yourself with this
infor mation befo re attempti ng ins tal lat io n or o the r
proce d ures.
Risk of Danger: These instructions contain
important safety information. Read them before
starting installation or servicing of the equipment.
Caution: Risk of Electric Shock
!
!
!
!!
11
NO.
2
3
4
5
6
7
8
9
10
13
Descriptions
7 digits used to display measured values
Total value
Import information, Export information
Max. Demand for Power or Current.
Pulse output 1and Pulse output2
Measurement units
PF = power factor Hz = frequency
Bar display of Power
Communication indicatior
Lock symbol
Tariff information
2.3 Scroll display by Buttons
After initialization and self-checking program, the meter
display the measured values. The default page is total
kWh . If the user wa nts to ch eck oth er inf orma tion , he
needs to press the scroll button on the front panel.
The display order by scroll button :
Total kWh→ Import kWhExport kWh→ Resettable kWh
Total kVArhImport kVArh→ Export kVArh→Resettable kVArh
→ Max. Power Demand→ VoltageCurrentWVar →
VA→ Power FactorFrequency →Pulse Constant→ Modbus ID
Baud Rate →Continuous Running Time
Display No:1,4~7,10~24.
*For SDM230-Modbus:
*For SDM230-2T:
Total kWh→ T1 total kWh→ T2 total kWhImport kWh→
Export kWh →resettable kWh→Total kVArhT1 total kVArh
→T2 total kVArh→Import kVArh→ Export kVArh→ resettable kVArh
Max. Power Demand→ Voltage CurrentW→ Var →VA
Power Factor Frequency Pulse Constant Modbus ID
Baud Rate Continuous Running Time
Display No: 1~24.
7Total reactive energy
Example: 10.00kVArh
Software version (please check
the real software version on the
product as the final).
Modbus ID or Mbus Primary Address
2.2 Initialization Display
All dis play s egments light up,
display check.
*For SDM230-Mbus:
Total kWh Impor t kWh Expo rt kWh Resettable kWh
Total kVArh Import kVArh Export kVArh→ Resettable kVArh
Max. Power Demand Voltage CurrentW→ Var →VA
→ Power Factor → Frequency →Pulse Constant
Mbus Primary AddressMbus Secondary Address
Baud Rate→Continuous Running Time
Display No:1,4~7,10~24.
2
T1 active energy
Example: 10.00kWh
(for SDM230-2T only)
3
T2 active energy
Example: 10.00kWh
(for SDM230-2T only)
1Total active energy
Example:70.00kWh
4Import(input) active energy
Example: 50.00kWh
5Export(output) active energy
Example: 20.00kWh
8
T1 reactive energy
Example: 2.00kVArh
(for SDM230-2T only)
6Resettable total energy
2.4 Set-up Mode
To get into Set-up Mode, the user needs to press the “Enter
button for 3 seconds.
17 Reactive power
Example: 1030Var
18 Apparent power
Example: 4811VA
19 Power factor
Example: 1.000
20 Frequency
Example: 49.99Hz
21 Pulse 2 constant
Example: 1000
22
Modbus address
Example: 001
Mbus primary address
Example:001
22-1
High and Low bit of MBUS
Secondary address
(Default 00 00 00 01)
Example: if the Secondary
address high bit is 0000,
low bit is 0001,that means
the integral Secondary
address is 00 00 00 01
(for SDM230-Mbus only)
23 Baud rate
Example: 9600
Continuous running time
(since last time reset)
24
This document provides operating, maintenance and
installation instructions of SDM230 series made by
Ea str on E le ct ron ic Co . , L td . Th e S DM 23 0 s er ies
measure and display the characteristics of single phase
two wire (1p2w) network. The SDM230 series covers 5
m o de l s : S DM 2 3 0 - M od b u s , SD M 2 3 0 -P u l s e , SD M 2 3 0 -
Mbus, SDM230-2T and SDM230-Std.
SDM230-
Pulse
U, I, P, Q, S , PF, Hz,
Dmd, kWh, kVArh,
Import, Export
NO
1:
congurable
2:
1000imp/kwh
NO
SDM230-
Std
1:
congurable
2:
1000imp/kwh
kWh, kVArh,
Import, Export
RS485
Modbus NO
Baud rate.
Total kWh.
Mbus Secondary Addres s (Low)
(for SDM230-Mbus only)
Mbus Secondary Addres s (High)
(for SDM230-Mbus only)
Total kWh→ Import kWhExport kWh→ Resettable kWh
total kVArhImport kVArh→ Export kVArh→resettable kVArh
→ Max. Power Demand→ VoltageCurrentWVar →
VA→ Power FactorFrequency →Pulse Constant
Display No:1,4~7,10~21.
*For SDM230-Pulse:
*For SDM230-Std:
Total kWh Impor t kWh Expo rt kWh Resettable kWh
Total kVArh Import kVArh Export kVArh→ Resettable kVArh
Pulse Constant→ Modbus ID→ Baud Rate →
Continuous Running Time
Display No:1,4~7,10~12, 21~24.
16 Active power
Example: 4700W
Current
Example: 30.156A
15
Voltage
Example: 229.8V
14
13 Max. power demand
Example: 6938W


Produkt Specifikationer

Mærke: Eastron
Kategori: Måleudstyr
Model: SDM230M

Har du brug for hjælp?

Hvis du har brug for hjælp til Eastron SDM230M stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måleudstyr Eastron Manualer

Eastron

Eastron SDM630-EV Manual

15 September 2024
Eastron

Eastron SDM54-M Manual

13 September 2024
Eastron

Eastron SDM72CTM Manual

15 August 2024
Eastron

Eastron SDM72D-M Manual

2 August 2024
Eastron

Eastron SDM230M Manual

29 Juli 2024
Eastron

Eastron SDM530D Manual

21 Juli 2024
Eastron

Eastron SDM230 Manual

21 Juli 2024

Måleudstyr Manualer

Nyeste Måleudstyr Manualer

Stamos

Stamos S-LS-28 Manual

15 Oktober 2024
Stamos

Stamos S-LS-86 Manual

15 Oktober 2024
Stamos

Stamos S-LS-61 Manual

15 Oktober 2024
Stamos

Stamos S-LS-81 Manual

15 Oktober 2024
Stamos

Stamos S-LS-84 Manual

15 Oktober 2024
Stamos

Stamos S-LS-74 Manual

15 Oktober 2024
Stamos

Stamos S-LS-42 Manual

15 Oktober 2024
Stamos

Stamos S-LS-75 Manual

15 Oktober 2024
Stamos

Stamos S-LS-35 Manual

15 Oktober 2024
Stamos

Stamos S-LS-38 Manual

15 Oktober 2024