Eberspacher Mini-Clock Manual

Eberspacher Opvarmning Mini-Clock

Læs nedenfor 📖 manual på dansk for Eberspacher Mini-Clock (1 sider) i kategorien Opvarmning. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
Operating / Installation Instructions
Mini-Clock
D
S
GB
F
1
2
3
ON
20:05
1
2
3
8
5
6
7
4
General remarks
Setting and operating the Mini-Clock
If a key is not depressed within 15 seconds, the display will return
to its initial state – Current time.
When setting the time with the keys 2 or 3, the setting speed is
accelerated when the key is kept depressed.
Up to three preset times can be set and activated on this Mini-
Clock. Each preset time is deactivated after the heating period,
and it must be newly activated for each new heating period – see
activate / deactivate the preset time.
Setting functions on the Mini-Clock
Setting-up for the first time:
After connection to the power supply all symbols on the display will
start to flash. The heater cannot be turned on in this state. The
current time has to be set first.
Press key 1: The clock time flashes. Set the time with key 2 or 3.
Press key 1: The time is displayed; the colon flashes.
Setting the time:
Press key 1 for more than 3 seconds: The time flashes. Set the time
with key 2 or 3. Press key 1 within 5 seconds: The time is displayed
and the colon flashes.
Note:
If, after the time has been set, key 1 is not pressed within 5 seconds,
the Mini-Clock will be transferred to the mode “Setting the Heating
Time”.
Setting the heating time:
Press key 1 for more than 3 seconds: The time flashes. The Mini-
Clock is automatically transferred to the mode “Setting the Heating
Time” if no key is pressed for 5 seconds.
The heating symbol is displayed, and the heating time flashes.
Set the heating time (10 to 120 minutes) with key 2 or 3.
Press key 1: The time is displayed once again and the colon flashes.
Setting the preset time:
Press key 1 once, twice or three times to call the preset time 1, 2
or 3. The display will then indicate the preset time, for instance 1
and symbol 1. Set the preset time with key 2 or 3. The preset time
is activated or deactivated with key 4. The “ON” symbol is displayed
when the preset time has been activated.
Symbol 1, 2 or 3 is displayed when the preset time is activated.
Operating functions of the Mini-Clock
Switching on the heater:
Press key 4. The heating duration is … minutes.
The display indicates the remaining heating time and symbol 7.
Switching off the heater:
Press key 4. The heating continues for approx. 3 minutes.
The display indicates the current time.
1Key to activate the setting capabilities
2 / 3 Time setting keys forwards / backwards
4ON / OFF key to activate / deactivate the preset time
5Current time, preset time and heating time
6Symbol for activated preset time
7Symbol for heater operation
8Symbol for preset time 1, 2 or 3
Continuous operation:
Press key 3 and keep it depressed while pressing key 4. The
heater will now remain switched on until key 4 (switching off the
heater) is pressed again.
Preset time – Activate / deactivate:
Press key 1 to select the preset time 1, 2 or 3. Activate or deacti-
vate the preset time with key 4.
The “ON” symbol is displayed when the preset time is activated.
Symbol 1, 2 or 3 is displayed when the preset time is activated.
Special functions only in conjunction
with the TP41 / TP41i remote control
Programming the receiver to recognize the transmitter:
Press key 2 and keep it depressed while pressing key 4.
The display indicates 2 horizontal lines.
The display returns to its initial state when the receiver has been
successfully programmed. The display automatically returns to the
initial status after 35 seconds if the transmitter is not recognized. In
this case repeat the above procedure once again.
Installing and connecting the Mini-Clock
Follow the drawing to install the Mini-Clock.
The drilling template (can be peeled off and is self-adhesive)
is applied on the front.
Follow the diagram to connect the Mini-Clock.
Note:
Do not press the display and control panel when installing the Mini-
Clock.
Connecting diagram
1
2
3
ON
20:05
o 7,5
o 2,5
Eberspächer
Mounting drawing
4
23
1
2
4
1
3
1 3
2 4
B1 S1
88:88
ge
br
bl
rt
0,5 br
0,5 ge
0,5 rt
4 3 2 1
B1
S1
Drilling template Resilient base
for uneven mounting surfaces
Connection for TP41 / TP41i remote control
Plug and socket case are shown from the line entry side.


Produkt Specifikationer

Mærke: Eberspacher
Kategori: Opvarmning
Model: Mini-Clock

Har du brug for hjælp?

Hvis du har brug for hjælp til Eberspacher Mini-Clock stil et spørgsmål nedenfor, og andre brugere vil svare dig




Opvarmning Eberspacher Manualer

Opvarmning Manualer

Nyeste Opvarmning Manualer