The Smoke/Heat Alarm is mounted on the EI 128R and when a fire is de-
tected the relay contacts change over. The electrically isolated contacts
can be used for signalling, turning on lights etc.
WARNING: This pattress must only be used with one of the above smoke
alarms as per these instructions - otherwise the unit will not comply with
the mandatory safety regulations.
With the yellow slide switch “on” (as supplied) the relay changes over
when the fire is detected and only resets when the smoke/heat alarm re-
sets. With the slide switch “off” the relay changes over for 2 to 12 seconds
when fire is detected and then resets – this is useful with warden call pan-
els. If momentary operation is required, push the slide switch gently and
carefully with a screwdriver to turn it off.
WARNING: Mains powered Smoke/Heat Alarms should be installed by a
qualified electrician in accordance with the Building Regulations for Elec-
trical Installations published by the Institution of Electrical Engineers
(UK). Failure to install the unit correctly may expose the user to shock or
fire hazards.
Warning: First disconnect the mains from the circuit to be used.
1.Chose a mounting position following the siting instructions in the
Smoke/Heat Alarm leaflet. Where the incoming wiring is on the surface of
the ceiling, the appropriately sized ducting/conduit must be chosen to
mate with the unit. Use a sharp knife to remove to material from the se-
lected knockout, making sure that there is no gap when mated with
ducting / conduit. There are three knockouts – two on the sidewall and
one on the rear.
2.Screw the pattress EI 128R to the ceiling after first removing the re-
quired knockout and bringing the house wires through it (see figure 1). If
the central knockout is being used, seal around the wires with silicone or
similar to prevent air draughts affecting the smoke entering the alarm.
3.Connect the house wires (L - Live, N - Neutral and IC - Interconnect, if it
is being used) to the terminal block on the pattress. If an EI 161R or EI
166R (with remote TEST/HUSH) is being installed, attach the “R” wire
from the EI 152 (see the EI 152 instruction) to the terminal marked “R” in
the pattress (see figure 1). If the EI 161R or EI 166R is being used with a
manual call point MCP400 or MCP400A then connect the R terminal to
the call point (see figure 2). Otherwise do not connect anything to the ”R”
terminal.
4.Connect the three wires (“L”, “N” and “IC”) from the pattress to the con-
nectors on the Smoke/Heat Alarms mounting plate. This “IC” wire must
be connected even if it is a single alarm installation. Connect the earth
wire (if present) from the house wiring directly to the terminal on the
mounting plate. Replace the cover over the terminal wires.
Connect the wires to the required relay contacts for controlling the auxil-
iary device (the contacts are isolated and are rated at 250VAC, 5 amps re-
sistive). If momentary relay operation is required, carefully and gently
slide the yellow switch to the off position with a small screwdriver (see fig-
ure 1).
5.Screw the mounting plate to the pattress pillars using the two screws
supplied.
6.Slide the alarm on to the mounting plate.
7.Connect the mains power – the green LED light on the alarm should be
on. When the test button is pressed the horn should sound and the relay
will switch within 10 seconds. (Note - with ionisation alarms the relay nor-
mally switches 4 seconds after the horn sounds. With optical alarms the
relay normally switches within 2 seconds of the horn sounding).
Note 1: A maximum of 12 Smoke/Heat Alarm of the types specified may
be interconnected to one EI 128R unit. When one alarm senses fire all in-
terconnected units will alarm and the relay will switch.
Note 2: An alarm with battery back-up will continue to operate during a
mains failure but will not be able to switch the relay. (The relay requires
the 230 VAC to operate).
Note 3: Devices connected to the relay contacts must not give a fire warn-
ing until the contacts have switched for at least 200mSec. (The contacts
may switch momentarily when subjected to electromagnetic interfer-
ence).
Aico Ltd., Mile End Business Park, Maesbury Road, Oswestry,
Shropshire SY10 8NN, U.K.
EI Electronics., Shannon Industrial Estate, Shannon, Co. Clare.
Installation
Pattress with Relay Model EI 128R
For use only with EI 140, 141, 144, 145, 146, 161, 161R,
164, 166, 166R Smoke/Heat Alarms
Relay Output 250VAC/5amps
Professional
®
P/N A13915 Rev 0
CONDUIT
N
NO
ON OFF
IC
NC
L
R
C
CONNECT RELAY WIRES
TO THIS TERMINAL BLOCK
CONNECT TO SMOKE ALAR
M
MOUNTING PLATE TERMINAL
S
FOR EI161R/166R
REMOTE CONTROL ONLY
DOUBLE
INSULATE
A
LL WIRES
KNOCKOUT
CONTINUOUS RELAY RELAY CHANGES
FOR 5 SECONDS
SLIDE SWITCH
NO
NC
N
C
IC
L
- NORMALLY OPEN
- EARTH (IF PRESEN
T)
- NORMALLY CLOSED
- NEUTRAL
- COMMON
- INTERCONNECT
- LIVE
N
IC
L
KNOCKOUT
Figure 1
R - Remote
N - Neutral
I
C - Interconnect
L - Live 2 3
Smoke Alarm
EI 161R or EI 166R
EI 152 Manual Call Poi
nt
MCP 400
(or MCP 400A
)
Pattress
EI 127R/128R
Mounting
Plate
EI 16XR
Figure 2
Produkt Specifikationer
Mærke: | Ei Electronics |
Kategori: | Detektor |
Model: | Ei128R |
Bredde: | 141 mm |
Dybde: | 21 mm |
Højde: | 141 mm |
Vægt: | 155 g |
Produktfarve: | Hvid |
Relativ luftfugtighed ved drift (H-H): | 0 - 90 % |
Driftstemperatur (T-T): | 0 - 40 °C |
Kan forbindes indbyrdes: | Ja |
Monteringstype: | Overflademonteret |
Indgangsspænding: | 240 V |
Mængde af sammenkoblede alarmer (maks): | 12 |
Backup batteri: | Ingen |
UL 94 antændelsesstandard: | V0 |
Indbygget relæ: | Ja |
Har du brug for hjælp?
Hvis du har brug for hjælp til Ei Electronics Ei128R stil et spørgsmål nedenfor, og andre brugere vil svare dig
Detektor Ei Electronics Manualer
3 August 2024
25 Oktober 2023
6 August 2023
16 November 2022
Detektor Manualer
- Detektor Bosch
- Detektor Denver
- Detektor Hager
- Detektor Extech
- Detektor Silverline
- Detektor Skil
- Detektor Pioneer
- Detektor Soler & Palau
- Detektor Garmin
- Detektor Pyle
- Detektor Nedis
- Detektor Abus
- Detektor Edimax
- Detektor Optex
- Detektor Smartwares
- Detektor Kyoritsu
- Detektor Laserliner
- Detektor Black And Decker
- Detektor Dometic
- Detektor Busch-Jaeger
- Detektor Trotec
- Detektor Honeywell
- Detektor Uniden
- Detektor König
- Detektor FireAngel
- Detektor Elro
- Detektor Steinel
- Detektor Powerfix
- Detektor Maginon
- Detektor Tripp Lite
- Detektor Mercury
- Detektor Genie
- Detektor National Geographic
- Detektor Alecto
- Detektor Olympia
- Detektor Techly
- Detektor B/R/K
- Detektor Voltcraft
- Detektor GEV
- Detektor Testboy
- Detektor Cobra
- Detektor Velleman
- Detektor FLIR
- Detektor JUNG
- Detektor Byron
- Detektor Vemer
- Detektor ORNO
- Detektor Netatmo
- Detektor Amprobe
- Detektor Fluke
- Detektor Hikvision
- Detektor Sun Joe
- Detektor Gossen
- Detektor Pentatech
- Detektor Testo
- Detektor Grothe
- Detektor Siedle
- Detektor Evolveo
- Detektor Multimetrix
- Detektor Axis
- Detektor X-Sense
- Detektor Vimar
- Detektor Dahua Technology
- Detektor ZKTeco
- Detektor Joy-It
- Detektor Nexa
- Detektor HT Instruments
- Detektor AcuRite
- Detektor Toolcraft
- Detektor Homematic IP
- Detektor V-TAC
- Detektor Schwaiger
- Detektor Beha-Amprobe
- Detektor Bearware
- Detektor Ferguson
- Detektor Inovonics
- Detektor AngelEye
- Detektor Royal Sovereign
- Detektor Marquant
- Detektor Safescan
- Detektor Xavax
- Detektor X4-Tech
- Detektor FireX
- Detektor DSC
- Detektor Iget
- Detektor Satel
- Detektor Sauter
- Detektor Garrett
- Detektor Kreator
- Detektor Gamma Scout
- Detektor Winland
- Detektor Escort
- Detektor Ebode
- Detektor System Sensor
- Detektor Guardian Avionics
- Detektor Thitronik
- Detektor Whistler
- Detektor Cavius
- Detektor PCE Instruments
- Detektor Flow Smoke Detector
- Detektor Benewake
- Detektor BeeSecure
- Detektor Fisher
- Detektor SureCall
- Detektor STI
- Detektor Schabus
- Detektor Zircon
- Detektor Sanwa
- Detektor Minelab
- Detektor Resideo
- Detektor BlendMount
- Detektor K40
- Detektor Gewiss
- Detektor Seco-Larm
- Detektor Silent Knight
- Detektor S.E. International
- Detektor Rocky Mountain
- Detektor Skyscan
- Detektor Noyafa
- Detektor Gigahertz Solutions
Nyeste Detektor Manualer
21 November 2024
21 November 2024
19 November 2024
18 November 2024
16 November 2024
16 Oktober 2024
16 Oktober 2024
30 September 2024
21 September 2024
13 September 2024