Emko Eco Light Manual
Læs nedenfor 📖 manual på dansk for Emko Eco Light (4 sider) i kategorien Termostat. Denne guide var nyttig for 10 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/4
3
2
1
PO1
PO2
°C
°F
/
LITE
Eco
AL1
45
6
PO1
PO2
°C
°F
/
LITE
Eco
AL1
1- Before mount ng the dev ce n your � � �
panel, make sure that the cutout s of �
the r ght s ze.� �
2- Check front panel gasket pos t on.� �
3- Insert the dev ce through the cutout. �
If the mount ng clamps are on the un t, � �
put out them before nsert ng the un t to � � �
the panel.
4- Insert the mount ng clamps to the two �
of des gnated holes that located four �
s des of dev ce. � �
5- Drag the mount ng clamps n � �
d rect on 5 unt l the dev ce completely � � � �
� � � �mmob le w th n the panel.
6- In order to remove dev ce push on �
the mount ng clamp as shown w th � �
arrow 6 and pull back.
Introduct�on Brochure. ENG EcoLITE 01 V06 10/19
DISPLAY
Process D splay:� 16 mm Red 3 d g t LED D splay� � �
Set Value D splay:� 9 mm Orange 4 d g t LED D splay� � �
Led Ind cators:� PO1 (Process Output-1 Status Led), PO2 (Process
Output-2 Status Led), ºC, ºF LEDs
ENVIRONMENTAL RATINGS and PHYSICAL SPECIFICATIONS
Operat ng Temperature:� 0...50ºC
Hum d ty:� � 0-90%RH (none condens ng)�
Protect on Class:� IP65 at front, IP20 at rear
We ght:� 150 gr.
D mens on:� � 48 x 48 mm, Depth: 86,5 mm
Panel CutOut: 46 x 46 mm
Access and Change Set Values
Eco LITE, On/Off Temperature Control Un t�
- 3 d g t process (PV) and 4 d g t set (SV) d splay� � � � �
- Process �nput (TC,RTD)
- ON/OFF control form
- Selectable heat ng and cool ng funct on� � �
- Operat ng type select on w th hysteres s� � � �
- Adjustment of temperature offset value
- M n mum pull ng t me adjustment for control outputs� � � �
- Password protect on for programm ng mode� �
Eco ser es temperature controllers are des gned for measur ng and � � �
controll ng temperature. They can be used n many appl cat ons w th � � � � �
the r TC and RTD temperature measurement � �nput, On/Off control form
and heat ng and cool ng select on. � � �
They are ma nly used n glass, plast c, petro-chem stry, text le, � � � � �
automot ve and mach ne product on � � � � �ndustr es.
SPECIFICATIONS
Process Input: TC, RTD
Thermocouple (TC): J, K, R, S, T and L (IEC584.1)(ITS90)
Termores stance (RTD): Cu-50 and PT-100 (IEC751)(ITS90)�
Measurement Range: Please refer to process �nput type select on � �n
process menu parameters sect on.�
Accuracy:
Thermocouple (TC):( ± 0.25% of full scale or ± 3ºC, wh ch one � �s
greater) ±1 d g t max. � �
Thermores stance (RTD):( ± 0.25% of full scale or ± 2ºC, wh ch one � � �s
greater) ±1 d g t max.� �
Cold Junct on Compensat on:� � Automat cally ±0.1°C/1°C�
L ne Compensat on:� � Max mum 10 Ohm�
Sensor Break Protect on:� Upscale
Sampl ng Cycle:� 0.1 second
Input F lter:� Programmable
Control Form: ON/OFF
ON/OFF Hysteres s:� It can be conf gured for two control outputs �
OUTPUT
Process Output - 1: Relay (5A@250V at res st ve load)V� �
Process Output - 2: Relay (5A@250VVat res st ve load)� �
ON/OFF TEMPERATURE CONTROL UNIT
LITE
Eco
SUPPLY VOLTAGE (It must be determ ned � �n order)
230V (±15%) 50/60Hz - 2VAV
115V (±15%) 50/60Hz - 2VAV
100-240V 50/60Hz - 2VAV
24V (±%15) 50/60Hz - 2VAV
24V (±%15) 50/60Hz - 2VAW
10...30V - 2WZ
Electr cal W r ngs� � �
The Dev ce w th One Relay:� �
The Dev ce w th Two Relays:� �
To reduce the effect of electr cal no se on dev ce, low voltage l ne (espec ally sensor � � � � �
� � � � � �nput cable) w r ng must be separetely from h gh current and voltage l ne. If poss ble,
use sh elded cable and sh eld must be connected to ground only one s de.� � �
c
LITE
Eco
1
2
3
4
5
6
7
8
9
10
11
12
13
14
C
NO
Process
Input
5A@250V
PT-100
TC
Supply
Sw tch�
L
N
Supply
Voltage
1A T
Fuse
PO1
(Process Output 1)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
C
NO
NO
PO1
(Process Output 1)
PO2 / AL1
(Process Output 2 or
Alarm Output 1)
Process
Input
5A@250V
5A@250V
PT-100
TC
Supply
Sw tch�
L
N
Supply
Voltage
1A T
Fuse
LITE
Eco
D mens ons� �
6 mm / 0.24 nch�80,52 mm / 3.17 nch�
Max mum 9 mm / 0.35 nch� �
48 mm / 1.89 nch�
48 mm / 1.89 nch�
PO1
PO2
°C
°F
/
LITE
Eco
AL1
Panel Mount ng�
PO2
PO1
AL1
AL2
°C
°F
/
Press ncrement or decrement�
button to change Set1 value.
Press Enter button to save new
Set1 value and open Set2 screen.
Ma n Screen�
PO2
PO1
AL1
AL2
°C
°F
/ PO2
PO1
AL1
AL2
°C
°F
/
Ma n Screen�
PO2
PO1
AL1
AL2
°C
°F
/PO2
PO1
AL1
AL2
°C
°F
/ PO2
PO1
AL1
AL2
°C
°F
/
Press ncrement or decrement�
button to change Set2 value.
Press Enter button to save new
Set2 value and return ma n screen.�
Note1: User can ex t from set value sect on w thout sav ng the values by press ng � � � � �
button. If no operat on for 120 seconds, dev ce automat cally ex ts from Set Value � � � �
sect on.�
Note2: D splayed set value at ma n screen could be changed accord ng to � � �
parameter
Note3: Set values can be adjusted between Set Value Low and H gh L m ts.� � �
PO2
PO1
AL1
AL2
°C
°F
/
Ma n Screen�
PO2
PO1
AL1
AL2
°C
°F
/PO2
PO1
AL1
AL2
°C
°F
/
Password Screen
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*1
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*5
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*4
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*2
PO2
PO1
AL1
AL2
°C
°F
/ PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/ PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*3
PO2
PO1
AL1
AL2
°C
°F
/
PO2
PO1
AL1
AL2
°C
°F
/
*3
*3
To enter program menu
press button
Enter Password w th�
�ncrement or decrement buttons.
Approve password
w th Enter button�
*1 - M n mum pull ng t me parameter for Output-1( ) s not seen unless operat on � � � � � �
type select on for output-1 parameter( ) s set as .� �
*2 - Out-2( ) parameters are not seen on dev ces w th one relay.� �
*3 - Alarm parameters( , and ) are not seen unless operat on type�
select on for output-2 parameter( ) s set as . � �
*4 - M n mum pull ng t me parameter for Output-2( ) s not seen unless operat on � � � � � �
type select on for output-2 parameter( ) s set as .� �
*5 - If s d fferent from 0 and user enters to program menu w thout enter ng the � � � �
password menu s not seen.�
Note: User can ex t from any parameter screen w thout sav ng the values by � � �
press ng button. If no operat on for 120 seconds, dev ce automat cally return to � � � �
the ma n screen.�
Easy Access D agram For Program Parameters�
: Output-1 Parameters
: Operat on Type Select on for Output-1. It can be or .� �
(Default: )
: Hysteres s Value for Output-1. It can be adjusted from %0 to %50 of �
the Operat on Scale ( - ). (Default: 3)�
: Set1 Value Low L m t. M n mum Set1 value s def ned w th th s � � � � � � � �
parameter. It can be adjusted from Operat on Scale Low L m t( ) to � � �
Set1 H gh L m t( ). (Default: 0)� � �
: Set1 Value H gh L m t. Max mum Set1 value s def ned w th th s � � � � � � � �
parameter. It can be adjusted from Set1 Low L m t( ) to Operat on � � �
Scale H gh L m t( ). (Default: 500)� � �
: M n mum Pull ng T me for Output-1. When Output-1 s nact ve th s � � � � � � � �
t me must be exp red for Output-1 to become act ve aga n. It can be � � � �
adjusted from 0 to 100 seconds. (Default: 0)
: Output-2 Parameters (Only for dev ces w th two relays)� �
: Operat on Type Select on for Output-2. It can be , or . � �
(Default: )
: Hysteres s Value for Output-2. It can be adjusted from %0 to %50 of �
the Operat on Scale ( - ). (Default: 3)�
: Alarm type select on. See "Alarm Types" sect on. (Default: )� �
: Set2 Value Low L m t. M n mum Set2 value s def ned w th th s � � � � � � � �
parameter. It can be adjusted from Operat on Scale Low L m t( ) to � � �
Set1 H gh L m t( ). (Default: 0)� � �
: Set2 Value H gh L m t. Max mum Set2 value s def ned w th th s � � � � � � � �
parameter. It can be adjusted from Set2 Low L m t( ) to Operat on � � �
Scale H gh L m t( ). (Default: 500)� � �
: M n mum Pull ng T me for Output-2. When Output-2 s nact ve th s � � � � � � � �
t me must be exp red for Output-2 to become act ve aga n. It can be � � � �
adjusted from 0 to 100 seconds. (Default: 0)
: Alarm on Delay T me. It can be adjusted from 0 to 9999 seconds. �
(Default: 0)
: Alarm off Delay T me. It can be adjusted from 0 to 9998 seconds. If �
� � � � �t s h gher than 9998, s seen on the screen and alarm latch ng
output s selected. In alarm latch ng output mode n order to make � � �
pass ve alarm outputs, press enter button at ma n screen. (Default: 0)� �
: Protec on Menu Parameters�
: Password for access ng to the programm ng sect on. It can be � � �
adjusted from 0 to 9999.If s 0, password screen s not seen. If � �
� � � �s d fferent from 0 and user enters to the menu pages w thout enter ng the
password, all menus can be seen except protect on menu . But �
dev ce does not allow to do any changes n parameters. (Default: 0)� �
: User default parameters. Th s parameter s used for sav ng all � � �
parameters to restore later or restore all parameters saved before. If
� �s chosen, all parameters saved before are restored. If s chosen, all
parameters saved to restore later. If s chosen, noth ng s changed.� � �
(Default: )
: Th s parameter s used for restore factory defaults. If s chosen, � � �
factory defaults parameters restored. If s chosen, noth ng s changed.� � �
(Default: )
Remove all nput/output connect ons on term nals before � � �
restor ng parameters to user/factory defaults.�
c
: Process nput type select on. (Default: )� �
: J type (Fe,Cu,N ) Thermocouple , -199ºC,900ºC ; -199ºF,999ºF�
: J type (Fe,Cu,N ) Thermocouple , -19.9ºC,99.9ºC ; -19.9ºF,99.9ºF�
: K type (N ,Cr,N ) Thermocouple , -199ºC,999ºC ; -199ºF,999ºF� �
: K type (N ,Cr,N ) Thermocouple , -19.9ºC,99.9ºC ; -19.9ºF,99.9ºF� �
: R type (Pt13%RhPt) Thermocouple , 0ºC,999ºC ; 32ºF,999ºF
: R type (Pt13%RhPt) Thermocouple , 0.0ºC,99.9ºC ; 32.0ºF,99.9ºF
: S type (Pt10%RhPt) Thermocouple , 0ºC,999ºC ; 32ºF,999ºF
: S type (Pt10%RhPt) Thermocouple , 0.0ºC,99.9ºC ; 32.0ºF,99.9ºF
: T type (Cu,Cu,N ) Thermocouple , -199ºC,400ºC ; -199ºF,752ºF�
: T type (Cu,Cu,N ) Thermocouple , -19.9ºC,99.9ºC ; -19.9ºF,99.9�
: L type (N ,Cr,Co / N ,Fe,Mn,Cu) Thermocouple , -150ºC,800ºC ; � �
-199ºF,999ºF
: L type (N ,Cr,Co / N ,Fe,Mn,Cu) Thermocouple , -19.9ºC,99.9ºC ; � �
-19.9ºF,99.9ºF
: Cu-50 , -199ºC,200ºC ; -199ºF,392ºF
: Cu-50 , -19.9ºC,99.9ºC ; -19.9ºF,99.9ºF
: Pt-100 , -199ºC,650ºC ; -199ºF,999ºF
: Pt-100 , -19.9ºC,99.9ºC ; -19.9ºF,99.9ºF
: Un t Select on. or can be chosen. (Default: )� �
: Operat on Scale m n mum (Low L m t) value. It changes accord ng � � � � � �
to the process nput type and scale. (Default: -199)�
: Operat on Scale max mum (H gh L m t) value. It changes accord ng � � � � � �
to the process nput type and scale. (Default: 900)�
: D splay offset for process value. It can be adjusted from -10% of �
scale to 10% ofscale. It s added to the process d splay value. (Default: 0)� �
: Def ne f lter t me(sec) for d splayed value. (Default: 1.0)� � � �
: Select on of wh ch set value d splayed at ma n screen.� � � �
(Default: )
: Process Menu Parameters
Produkt Specifikationer
Mærke: | Emko |
Kategori: | Termostat |
Model: | Eco Light |
Har du brug for hjælp?
Hvis du har brug for hjælp til Emko Eco Light stil et spørgsmål nedenfor, og andre brugere vil svare dig
Termostat Emko Manualer
3 September 2024
28 August 2024
28 August 2024
27 August 2024
27 August 2024
27 August 2024
12 August 2024
Termostat Manualer
- Termostat Bosch
- Termostat SilverCrest
- Termostat Siemens
- Termostat GE
- Termostat Daikin
- Termostat Panasonic
- Termostat Hager
- Termostat TP-Link
- Termostat AEG
- Termostat Gigaset
- Termostat Finder
- Termostat Atag
- Termostat Emos
- Termostat Google
- Termostat Worcester
- Termostat TFA
- Termostat Baxi
- Termostat Carel
- Termostat De Dietrich
- Termostat Buderus
- Termostat AVM
- Termostat Hama
- Termostat Theben
- Termostat Busch-Jaeger
- Termostat Trotec
- Termostat Honeywell
- Termostat Ariston Thermo
- Termostat Truma
- Termostat Elro
- Termostat Max
- Termostat Vaillant
- Termostat RADEMACHER
- Termostat Carrier
- Termostat Danfoss
- Termostat Wolf
- Termostat Nest
- Termostat Dimplex
- Termostat Eberle
- Termostat Grässlin
- Termostat Heimeier
- Termostat Junkers
- Termostat Salus
- Termostat TrickleStar
- Termostat Weishaupt
- Termostat Alecto
- Termostat Westfalia
- Termostat Boneco
- Termostat HQ
- Termostat EnerGenie
- Termostat Schneider
- Termostat Basetech
- Termostat Tesla
- Termostat Grohe
- Termostat Ferroli
- Termostat Velleman
- Termostat Perel
- Termostat Joblotron
- Termostat Saunier Duval
- Termostat JUNG
- Termostat Vemer
- Termostat ORNO
- Termostat Watts
- Termostat Netatmo
- Termostat Technoline
- Termostat Somfy
- Termostat EQ3
- Termostat Techno Line
- Termostat Brennenstuhl
- Termostat Cotech
- Termostat Intergas
- Termostat Devolo
- Termostat Aube
- Termostat Elgato
- Termostat Renkforce
- Termostat SPC
- Termostat Hunter
- Termostat Viessmann
- Termostat Nobo
- Termostat Orbis
- Termostat Remeha
- Termostat Seitron
- Termostat Stiebel Eltron
- Termostat ACV
- Termostat Mikoterm
- Termostat Hive
- Termostat Tado
- Termostat Fibaro
- Termostat Noma
- Termostat POER
- Termostat EQ-3
- Termostat Vimar
- Termostat Oregon Scientific
- Termostat Corbero
- Termostat Remko
- Termostat Nexa
- Termostat Avidsen
- Termostat Crestron
- Termostat Emerson
- Termostat Elektrobock
- Termostat Delta Dore
- Termostat Homematic IP
- Termostat H-Tronic
- Termostat Schwaiger
- Termostat Bearware
- Termostat Ferguson
- Termostat Nefit
- Termostat Amfra
- Termostat Itho
- Termostat Fenix
- Termostat Magnum
- Termostat Horstmann
- Termostat Oventrop
- Termostat King
- Termostat Arnold Rak
- Termostat Heatmiser
- Termostat Itho-Daalderop
- Termostat Bticino
- Termostat Sygonix
- Termostat Plieger
- Termostat Conrad
- Termostat Zehnder
- Termostat Bulex
- Termostat UPM
- Termostat Optima
- Termostat AWB
- Termostat Xavax
- Termostat Fantini Cosmi
- Termostat Niko
- Termostat Gira
- Termostat Eneco
- Termostat Frico
- Termostat Vasco
- Termostat Radson
- Termostat Go Green
- Termostat Extraflame
- Termostat ICY
- Termostat HomeMatic
- Termostat Computherm
- Termostat Brink
- Termostat Drayton
- Termostat Heatit
- Termostat 2Heat
- Termostat Bryant
- Termostat Eqiva
- Termostat Etherma
- Termostat Veria
- Termostat Emmeti
- Termostat Thermy
- Termostat Coati
- Termostat Essent
- Termostat ThermoSmart
- Termostat Plugwise
- Termostat Eurotronic
- Termostat Hornbach
- Termostat Tru Components
- Termostat HomePilot
- Termostat Muller
- Termostat Worcester-Bosch
- Termostat Econo-Heat
- Termostat VDH
- Termostat PECO
- Termostat IR-V
- Termostat EasyTemp
- Termostat Intertechno
- Termostat Helios (Amfra)
- Termostat Easy Timer
- Termostat Z-Wave
- Termostat Hugo Muller
- Termostat IMIT
- Termostat Innogy
- Termostat Wallair
- Termostat Maico
- Termostat Levica
- Termostat Ouellet
- Termostat THERMAFLEX
- Termostat Wachendorff
- Termostat STI
- Termostat Yokis
- Termostat ChiliTec
- Termostat Eliwell
- Termostat Johnson Control
- Termostat Webasto
- Termostat Drayton Erie
- Termostat OJ ELECTRONICS
- Termostat Tellur
- Termostat RWE
- Termostat Lowes
- Termostat Jumo
- Termostat Warmup
- Termostat Qubino
- Termostat ELKO
- Termostat Gewiss
- Termostat Sinustec
- Termostat Rose LM
- Termostat Otio
- Termostat MundoControl
- Termostat Enda
- Termostat GENERAL Life
- Termostat Oreg
- Termostat Braeburn
Nyeste Termostat Manualer
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024