Your thermostat has the ability to reset all settings to the factory defaults. If you
are certain you want to do this:
In standby mode(when thermostat is turned off), press and hold button
and for 5 seconds until RES is shown on LCD.
Set the Time
Configure the menu
Resetting factory defaults
Setting temperature
1) Press and hold button until the time flashes
2) Use button or to change the time
3) Press button to accept and exit
Press or once, you will see set temperature flashing. Use
or again to adjust to the
temperature you want your room
to maintain. Press button to accept
and exit.
Buttons and LCD display
Buttons Press < 5 seconds Press > 5 seconds
Turning on/off thermostat
Menu button
Increase the set value
View floor temperature (AF model only)
Decrease the set value
Lock /unlock buttons
Reset to factory settings
(when thermostat is turned off)
+
+
Set the time
Confirm settings
The buttons are locked.
Displays when heating is active
Symbol Description
Set temperature
Set At
Sensor selection. This thermostat is a combination model allowing you to choose
between 3 different models. (A, AF,F )
A model: air only, with built in sensor
AF model: air & floo r , with both built in and remote sensor
F model: floor only, with remote sensor
Press and hold button for 5 seconds. Now you can see Menu 01, to proeceed to other menu, press button again. To exit menu, press button
Menu #
01
Switching differential.
Calibrate the room temperature. This feature is used to compensate for any difference
Calibrate the floor temperature. This feature is used to compensate for any difference
Set the floor temperature limit.
Select temperature format
06
03
04
05
02
Feature Description Factory Default
Feature Value
0
°C
40
°C
20
°C ~
40
°C
°C
/
°F
°C
A / AF / F A
Press or to select
The numbers of degree difference before switching.
between the displayed room temperature and a thermometer.
between the displayed floor temperature and a thermometer.
This feature is to protect the floor surface.
°C or °F.
The default is 1°C which means the thermostat will switch the
heating on
0.5°C below the set temperature and will turn it off 0.5°C above the set temperature.
With a 2°C differential,
the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
1°C 1°C ~ 5°C
-5°C ~ +5°C
0
°C -5°C ~ +5°C
Installation and Wiring
Carefully separate the front half of the thermostat from the back plate by placing a
small flat head terminal driver into the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat.
Place the thermostat front half somewhere safe. Terminate the diagrams below.
Screw the thermostat back plate on to the back box.
Re-connect the thermostat ribbon cable and clip the two halves together.
CS-11 LCD Simple Digital Thermostat
Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DW
Tel: 01993 824900 : www.emmeti.co.uk : e: sales@emmeti.co.uk


Produkt Specifikationer

Mærke: Emmeti
Kategori: Termostat
Model: CS-11- U9310020

Har du brug for hjælp?

Hvis du har brug for hjælp til Emmeti CS-11- U9310020 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termostat Emmeti Manualer

Termostat Manualer

Nyeste Termostat Manualer