Enda ET2411 Manual
Enda
Thermostaat
ET2411
Læs nedenfor 📖 manual på dansk for Enda ET2411 (2 sider) i kategorien Thermostaat. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
ENDA 2411 ON/OFF HEAT CONTROLLER ET
SET
°C
SET
ET2411
ENDA
°F C1
230V AC + % - %, 50/60Hz 24V AC %10 20 or 12/ /DC 10
Max. 3 VA
Power connector : 2.5mm² screw-terminal, Signal connector : 1,5mm² screw-terminal conenction.
EN 61326-1 : 2013 (Performance criterion B is satised for EN 61000-4-3)
EEPROM ( 10 )Min. years
Max. 100ohm
EN 61010-1 : 20 (Pollution degree 2, overvoltage category II) 10
12 bit , sampling time.resolution 100ms
Max. 2000m
Do not use the device in locations subject to corrosive and ammable gasses.
Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
0 ... +50 / -25... +70
°C °C without icing( )
According to EN60529; Front panel: IP65 Rear panel : IP20
S alc e Range Accuracy
EN 60751
- ... 0 °C -76.0...302.0°F60.0 15 .0
± 1% (for full scale) ± 1 Digit
Supply
HOUSING
Housing Type
Dimensions
Weight
Enclosure Materials
CONTROL
ontrolC Type
Control Algorithm
A/D Converter
Hysteresis
INPUT
Height
Ambient/Storage temperature
Relative Humidity
Protection Class
Input Type
NTC Sensor Typ 103AT-2
at 25 °C - 10 kOhm
77mm
61mm 5mm
2
Connection
Cable Panel Rubber
Packing
71,5mm
1
For 5A Models : 250V AC, 5A (resistive load), NO control output.
For 8A Models : 250V AC, 8A ( ), NO and NC control output.resistive load
For 16A Models : 250V AC, 16A ( ), NO control output.resistive load
For 5A Models : 5. Switching for no-load operation; 100.000 switching for 5A resistive load at 250VAC. Mio.
OUTPUT
Life Expectancy for Relay
C1 Output
Thank you for choosing ON/OFF Heat Controller.ENDA ET2411
Read this document carefully before using this device. The guarantee will be expired by device
demages if you don't attend to the directions in the user manual. Also we don't accept any
compensations for personal injury, material damage or capital disadvantages.
Holding screw
0.4-0.5Nm.
Equipment is protected throughout
by DOUBLE INSULATION
5
6
SUPPLY:
NOTE:
184-253V AC
50/60Hz 3VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identication of the
relevant instrument and it should be easily
accessible by the operator.
TECHNICAL SPECIFICATIONS
ENVIRONMENTAL CONDITIONS
ELECTRICAL CHARACTERISTICS
Power onsumptionC
Wiring
Indicator
EMC
Safety Requirements
Data Retention
Line Resistance
4 digits, 12.5mm, 7 segment red LED
Single and alarm .-setpoint control
Adjustable between 0.1 and 20.0°C/F.
according to DIN 43 700.Suitable for ush-panel mounting
5 1W77xH3 xD6 mm
Approx. 215g (A )fter packing
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Dimensions
For removing mounting clamps:
-Push the ush-mounting clamp
in direction as shown in the
gure below.Then,pull
out the clamp in direction .
1
2
Depth
Flush mounting
clamp
Flush mounting
clamp Panel cut-out Note:1) Panel thickness should
be maximum 7mm.
2) If there is no 60mm free
space at the back side of
the device,it would be
dicult to remove it from
the panel.
t
ENDA ET2411 is intended for installation within control panels. Make sure that the device is used only for
intended purpose. The shielding must be grounded on the instrument side. During an installation, all of the
cables that are connected to the device must be free of electrical power. The device must be protected against
inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is not exceeded.
All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables.
These cables should not be close to the power cables or components. The installation and electrical connections must
be carried out by a qualied sta and must be according to the relevant locally applicable regulations.
For 8A Models : 30. Switching for no-load operation; 300.000 switching for 8A resistive load at 250VAC. Mio.
For 16A Models : 30. Switching for no-load operation; 100.000 switching for 16A resistive load at 250VAC. Mio.
ET2411-230-08
DIGITAL THERMOSTAT
250V AC 8A
RESISTIVE LOAD
8 680407 71 5 299
Made in Turkey
C1
1 2 3 4 5 6 7 8 9 10 11 12
NTC
SN: XXXXXXXXX
ENDA INDUSTRIAL ELECTRONICS
ET2411-230-16
DIGITAL THERMOSTAT
250V AC 16A
RESISTIVE LOAD
8 680407 71 5 367
Made in Turkey
C1
1 2 3 4 5 6 7 8 9 10 11 12
NTC
SN: XXXXXXXXX
ENDA INDUSTRIAL ELECTRONICS
ET2411-SM-05
DIGITAL THERMOSTAT
250V AC 5A
RESISTIVE LOAD
8 680407 71 5 350
Made in Turkey
C1
1 2 3 4 5 6 7 8 9 10 11 12
NTC
SN: XXXXXXXXX
ENDA INDUSTRIAL ELECTRONICS
ET2411-230-08
DIGITAL THERMOSTAT
250V AC 8A
RESISTIVE LOAD
680407715299
Made in Turkey
C1
1 2 3 4 5 6 7 8 9 10 11 12
NTC
SN: XXXXXXXXX
ENDA INDUSTRIAL ELECTRONICS
Order Code : ET2411 - -
1 2
1 - Supply Voltage
230... 230V AC
24........24V AC
.....
0 /DC
012........12V AC/DC
SM.........7-24VAC/9-30VDC
2 - Relay Current Selection
05.....5A Re
08.....8A
lay Output
Relay Output
16...16A Relay Output
SET
°C
SET
ET2411
ENDA
°F C1
- 77 x 35mm sized.
- Single NTC sensor input.
- Zero point input shift.
- Selectable heating or cooling control for C1 relay output.
- Upper and lower setpoint limits can be adjusted.
- Temperature unit can be selected as °C or °F.
- CE marked according to European Norms.
- Selectable heating or cooling control.
- In the case of sensor failure, relay state can be set to ON or OFF.
english
SURAN Industrieelektronik
Dettinger Str. 9
D-72160 Horb a.N.
Tel.: +49 (0)7451 / 625 617 E-mail : info@suran-elektronik.de
Fax: +49 (0)7451 / 625 0650 Internet : www.suran-elektronik.de
up to date: 25.03.2019, modication reserved and can be change any time previous notice !
ET2411-E-25032019
1. / 2
R HS
Konform
Produkt Specifikationer
Mærke: | Enda |
Kategori: | Thermostaat |
Model: | ET2411 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Enda ET2411 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Thermostaat Enda Manualer
3 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
Thermostaat Manualer
- Thermostaat Bosch
- Thermostaat Siemens
- Thermostaat Hager
- Thermostaat TP-Link
- Thermostaat AEG
- Thermostaat Atag
- Thermostaat Emos
- Thermostaat TFA
- Thermostaat Baxi
- Thermostaat De Dietrich
- Thermostaat Buderus
- Thermostaat AVM
- Thermostaat Theben
- Thermostaat Honeywell
- Thermostaat Truma
- Thermostaat Elro
- Thermostaat Max
- Thermostaat Vaillant
- Thermostaat Carrier
- Thermostaat Danfoss
- Thermostaat Wolf
- Thermostaat Dimplex
- Thermostaat Eberle
- Thermostaat Grässlin
- Thermostaat Junkers
- Thermostaat Salus
- Thermostaat Weishaupt
- Thermostaat Westfalia
- Thermostaat HQ
- Thermostaat EnerGenie
- Thermostaat Schneider
- Thermostaat Basetech
- Thermostaat Ferroli
- Thermostaat Perel
- Thermostaat Saunier Duval
- Thermostaat JUNG
- Thermostaat Vemer
- Thermostaat ORNO
- Thermostaat Watts
- Thermostaat Netatmo
- Thermostaat Technoline
- Thermostaat Somfy
- Thermostaat EQ3
- Thermostaat Techno Line
- Thermostaat Devolo
- Thermostaat SPC
- Thermostaat Hunter
- Thermostaat Viessmann
- Thermostaat Nobo
- Thermostaat Orbis
- Thermostaat Remeha
- Thermostaat Stiebel Eltron
- Thermostaat Tado
- Thermostaat Fibaro
- Thermostaat POER
- Thermostaat EQ-3
- Thermostaat Vimar
- Thermostaat Corbero
- Thermostaat Remko
- Thermostaat Avidsen
- Thermostaat Crestron
- Thermostaat Elektrobock
- Thermostaat Delta Dore
- Thermostaat Homematic IP
- Thermostaat H-Tronic
- Thermostaat Emko
- Thermostaat Bearware
- Thermostaat Nefit
- Thermostaat Amfra
- Thermostaat Itho
- Thermostaat Magnum
- Thermostaat Horstmann
- Thermostaat King
- Thermostaat Arnold Rak
- Thermostaat Heatmiser
- Thermostaat Itho-Daalderop
- Thermostaat Bticino
- Thermostaat Plieger
- Thermostaat Conrad
- Thermostaat Zehnder
- Thermostaat Bulex
- Thermostaat Optima
- Thermostaat AWB
- Thermostaat Xavax
- Thermostaat Fantini Cosmi
- Thermostaat Niko
- Thermostaat Gira
- Thermostaat Eneco
- Thermostaat Frico
- Thermostaat Radson
- Thermostaat Go Green
- Thermostaat ICY
- Thermostaat Computherm
- Thermostaat Drayton
- Thermostaat Bryant
- Thermostaat Eqiva
- Thermostaat Etherma
- Thermostaat Emmeti
- Thermostaat Thermy
- Thermostaat Coati
- Thermostaat Essent
- Thermostaat ThermoSmart
- Thermostaat Plugwise
- Thermostaat Eurotronic
- Thermostaat Hornbach
- Thermostaat HomePilot
- Thermostaat Econo-Heat
- Thermostaat VDH
- Thermostaat PECO
- Thermostaat Z-Wave
- Thermostaat IMIT
- Thermostaat Wallair
- Thermostaat Maico
- Thermostaat Levica
- Thermostaat THERMAFLEX
- Thermostaat Wachendorff
- Thermostaat STI
- Thermostaat ChiliTec
- Thermostaat Eliwell
- Thermostaat Johnson Control
- Thermostaat Webasto
- Thermostaat Drayton Erie
- Thermostaat RWE
- Thermostaat Lowes
- Thermostaat ELKO
- Thermostaat Gewiss
- Thermostaat Rose LM
- Thermostaat Otio
- Thermostaat MundoControl
- Thermostaat GENERAL Life
Nyeste Thermostaat Manualer
18 September 2024
18 September 2024
18 September 2024
17 September 2024
17 September 2024
16 September 2024
16 September 2024
16 September 2024
15 September 2024
15 September 2024