Energizer CR2450 Manual

Energizer Accu CR2450

Læs nedenfor 📖 manual på dansk for Energizer CR2450 (1 sider) i kategorien Accu. Denne guide var nyttig for 14 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/1
Classification: "Lithium Coin"
Chemical System:
Lithium / Manganese Dioxide (Li/MnO2)
Designation: ANSI / NEDA-5029LC, IEC-CR2450
Nominal Voltage: 3.0 Volts
Typical Capacity:
620 mAh (to 2.0 volts)
(Rated at 7.5K ohms at 21°C)
Typical Weight: 6.8 grams (0.22 oz.)
Typical Volume: 2.4 cubic centimeters (0.14 cubic inch)
Max Rev Charge: 1 microampere
Energy Density: 183 milliwatt hr/g, 647 milliwatt hr/cc
Typical Li Content: < 0.3g
Operating Temp: -30C to 60C
Self Discharge: ~1% / year
Load Cutoff
2.0V
(ohms) (hours)
7,500 1,590 ContinuousBkgnd Drain:
7.5K ohms
0.39 mA @2.9V
Pulse Drain: 2 seconds X 12 times/day
300 ohms
9.0 mA @2.7V
Safety:
(1) KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to
serious injury or death in as little as 2 hours due to chemical burns and
potential perforation of the esophagus. Immediately see doctor; have
doctor phone (800) 498-8666.
(2) Battery compartment design. To prevent children from removing
batteries, battery compartments should be designed with one of the
following methods: a) a tool such as screwdriver or coin is required to open
battery compartment or b) the battery compartment door/cover requires
the application of a minimum of two independent and simultaneous
movements of the securing mechanism to open by hand. Screws should
remain captive with the battery door or cover.
Industry Standard Dimensions
Simulated Application test
Typical Performance at 21°C (70°F)
ENERGIZER CR2450
Specifications
mm (inches)
Lithium Coin
Continuous
Contents herein do not constitute a warranty and are for reference only.
Typical Drains:
at 2.9V
(mA)
0.39
Pulse Test at 21°C (70°F)
Typical Discharge Characteristics
Internal Resistance Characteristics
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
Schedule:
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0 400 800 1200 1600
Voltage, CCV
Service, Hours
Load: 7.5K ohms - Continuous
Typical Drain @ 2.9V: 0.39 mA
0
20
40
60
80
100
120
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0 100 200 250 300 500 60050
IR, ohms
Voltage, CCV
Capacity, mAh
IR
Pulse
Bkgnd
24.50 (0.965)
24.30 (0.957)
R1.25 (0.049) Ref.
R0.75 (0.030) Ref.
3.45 (0.136) Ref.
3.15 (0.124) Ref.
1.00 (0.039) Ref.
Minimum
5.00 (0.197)
4.60 (0.181)
0.25 (0.010) Maximum Ref.
Permissible deflection from a flat.
Form No. 2450NA0618 Page 1 of 1


Produkt Specifikationer

Mærke: Energizer
Kategori: Accu
Model: CR2450

Har du brug for hjælp?

Hvis du har brug for hjælp til Energizer CR2450 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Accu Energizer Manualer

Energizer

Energizer CR2450 Manual

9 August 2024
Energizer

Energizer XP8000 Manual

8 August 2024

Accu Manualer

Nyeste Accu Manualer

Ranex

Ranex RX3328 Manual

15 December 2024
Milwaukee

Milwaukee M18 HB3 Manual

13 December 2024
Milwaukee

Milwaukee M4 B2 Manual

13 December 2024
Milwaukee

Milwaukee M18 HB12 Manual

13 December 2024
Milwaukee

Milwaukee M28 BX Manual

13 December 2024
Milwaukee

Milwaukee M18 HB5.5 Manual

13 December 2024
Milwaukee

Milwaukee M18 HB8 Manual

13 December 2024
Milwaukee

Milwaukee M18 FB8 Manual

13 December 2024
Milwaukee

Milwaukee M18 FB12 Manual

13 December 2024