Extech 38070 Manual


Læs nedenfor 📖 manual på dansk for Extech 38070 (2 sider) i kategorien Multimeter. Denne guide var nyttig for 13 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
User’s Guide
Analog Multimeter
Model 38070
Introduction
Congratulations on your purchase of the Extech model 38070 Analog
Multimeter. This device measures AC/DC Voltage, DC Current, Resistance,
and dB, displaying measurements in analog format. Properly used, this meter
will provide many years of reliable service.
WARNING: USE EXTREME CAUTION IN THE USE OF THIS DEVICE.
Improper use of this device can result in injury or death. Follow all safeguards
suggested in this manual in addition to the normal safety precautions used in
working with electrical circuits. DO NOT service this device if you are not
qualified to do so.
Safety Instructions
This meter has been designed for safe use, but must be operated with caution.
The rules listed below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified
maximum:
Input Protection Limits
Function Maximum Input
V DC or V AC 500V AC and DC
mA DC 500mA DC
Resistance 50V DC/AC
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds
500V above earth ground.
4. NEVER connect the meter leads across a voltage source while the
function switch is in the current or resistance mode. Doing so can
damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and disconnect the
power when making resistance tests.
6. ALWAYS turn off power and disconnect test leads before opening the
covers to replace the fuse or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse
covers are in place and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
Safety Symbols
This symbol adjacent to another symbol, terminal or operating
device indicates that the operator must refer to an explanation
in the Operating Instructions to avoid personal injury or damage
to the meter.
This WARNING symbol indicates a potentially hazardous
situation, which if not avoided, could result in death or serious
injury.
This CAUTION symbol indicates a potentially hazardous
situation, which if not avoided, may result damage to the
product.
This symbol advises the user that the terminal(s) so marked
must not be connected to a circuit point at which the voltage
with respect to earth ground exceeds 500V.
This symbol adjacent to one or more terminals identifies them
as being associated with ranges that may, in normal use, be
subjected to particularly hazardous voltages. For maximum
safety, the meter and its test leads should not be handled when
these terminals are energized.
This symbol indicates that a device is protected throughout by
double insulation or reinforced insulation.
Controls and Jacks
1. Scale
2. Pointer
3. Scale zero adjust
4. Ohms zero adjust
5. Rotary function switch
6. Positive V, mA and input jack
7. COM input jack
Specifications
Function Range Accuracy
DC Voltage 500V
± 4% of full scale
250V
50V
10V
AC Voltage
(50/60Hz)
500V
± 5% of full scale
250V
50V
10V
DC Current
250mA
± 4% of full scale 50Ma
0.5mA
Resistance Rx10 (10,000 ± 5% of full scale
Rx1k (1,000,000
Decibels -10 to +56 dB (4 ranges) 0dB=1mW in 600
Max input voltage 500V AC/DC
Input Sensitivity, 2kV
Frequency Range 50/60Hz
Battery 0ne (1) 1.5V AA battery
Fuse 500mA/250 fast blow (5mmx20mm)
Operating Temperature 41 oF to 104oF (5oC to 40oC)
Storage Temperature 14 oF to 122oF (-10oC to 50oC)
Operating Humidity Max 80% up to 87ºF (31ºC) decreasing linearly to
50% at 104ºF (40ºC)
Storage Humidity <80%
Operating Altitude 7000ft. (2000meters) maximum.
Weight 3.88oz (110g)
Size 3.82x3.34x1.3” (97x65x33mm)
Safety For indoor use and in accordance with the
requirements for double insulation to IEC1010-1
(1995): EN61010-1 (1995) Overvoltage Category II
500V, Pollution Degree 2. UL, CE Approved
1
2
3
4
5
6
7
WARNING
CAUTION
MAX
500V
SupportLines:U.S.(877)439 (603) 3248324;International:+1  ‐7800
Technical  ‐Support: Option 3; E mail: support@extech.com
Repair & Returns:Option4; ‐E mail: repair@extech.com
Productspecificationsare subject tochangewithoutnotice
Please ‐ ‐visit our website for the most up to date information
www.extech.com
FLIRCommercialSystems,Inc.,9   Townsend West, Nashua, NH 03063
USA
ISO9001Certified


Produkt Specifikationer

Mærke: Extech
Kategori: Multimeter
Model: 38070

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech 38070 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Extech Manualer

Extech

Extech MA440 Manual

28 August 2024
Extech

Extech EX355 Manual

27 August 2024
Extech

Extech EX623 Manual

27 August 2024
Extech

Extech MA443 Manual

27 August 2024
Extech

Extech Ex 830 Manual

17 August 2024
Extech

Extech EX 710 Manual

13 August 2024
Extech

Extech MN35 Manual

29 Juli 2024
Extech

Extech EX540 Manual

28 Juli 2024
Extech

Extech EX360 Manual

27 Juli 2024
Extech

Extech MM560A Manual

25 Juli 2024

Multimeter Manualer

Nyeste Multimeter Manualer

Velleman

Velleman DVM840 Manual

4 Oktober 2024
Voltcraft

Voltcraft VC131 SE Manual

1 Oktober 2024
Voltcraft

Voltcraft PMM 3005-20 Manual

30 September 2024
Velleman

Velleman DVM831 Manual

22 September 2024
Bearware

Bearware 306998 Manual

21 September 2024
Bearware

Bearware 307001 Manual

21 September 2024
Kyoritsu

Kyoritsu KEW2046R Manual

20 September 2024
Silverline

Silverline 650926 Manual

17 September 2024
Digitus

Digitus DA-70612 Manual

15 September 2024