Extech MN36 Manual


Læs nedenfor 📖 manual på dansk for Extech MN36 (2 sider) i kategorien Multimeter. Denne guide var nyttig for 41 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
MN36- -US_V2.3 10/20 en
Safety
This symbol, adjacent to another symbol or terminal, indicates
the user must refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under
normal use, hazardous voltages may be present
Double insulation
1. Improper use of this meter can cause damage, shock, injury or death.
Read and understand this user manual before operating the meter.
2. Make sure any covers or battery doors are properly closed and ured.
3. Always remove the test leads before replacing the battery or fuses.
4. Inspect the condition of the test leads and the meter itself for any
damage before operating the meter. Repair any damage before use.
5. Do not exceed the maximum rated input limits.
6. Use great care when making measurements if the voltages are
greater than 25VAC rms or 35VDC. These voltages are considered a
shock hazard.
7. Always discharge capacitors and remove power from the device
under test before performing Diode, Resistance or Continuity tests.
8. Remove the battery from the meter if the meter is to be stored for
long periods.
9. To avoid electric shock, do not measure AC current on any circuit
whose voltage exceeds 250V AC.
Input Limits
Function
Maximum Input
VDC, VAC
600V AC/600V AC
Resistance, Diode, Continuity
500V DC/AC
mA DC
200mA DC
10A DC
10A DC (15 seconds max.
every 15 min.)
Frequency
250V DC/AC
Two-year Warranty
FLIR Systems, Inc. warrants this Extech brand instrument to be free
of defects in parts and workmanship for from date of two years
shipment (a six-month limited warranty applies to sensors and cables).
To view the full warranty text please visit:
http://www.extech.com/support/warranties.
Calibration and Repair Services
FLIR Systems, Inc. oers calibration and repair services r the fo
Extech brand products we sell. We oer NIST traceable calibration for
most of our products. Contact us for information on calibration and repair
availability, refer to the contact information below. Annual calibrations
should be performed to verify meter performance and accuracy. Product
specications are subject to change without notice. Please visit our
website for the most up- -date product information: . to www.extech.com
Contact Customer Support
Customer Support Telephone List: https://support.ir.com/contact
Calibration, Repair and Returns, : repair@extech.com
Technical Support: https://support.ir.com
Copyright 2004-2020 FLIR Systems, Inc. ©
All rights reserved including the right of reproduction in whole or in part
in any form
www.extech.com
User Manual
MiniTecTM Series
Model MN36
Auto-Ranging Mini MultiMeter
Introduction
Congratulations o Auto-Ranging n your purchase of Extech’s MN36
Multimeter. This meter measures AC/DC Voltage, AC/DC Current,
Resistance, Capacitance, Frequency, Temperature, Diode Test and
Continuity. Proper use and care of this meter will provide many years of
reliable service.
Specications
Accuracy Stated at 73oF 10oF (23oC 5 oC) and less than
70% RH
Diode Test Test current of 0.6mA maximum, open circuit
voltage 1.5V DC typical
Continuity Check Audible signal will sound if the resistance is less
than approximately <8
Temperature sensor Requires type K thermocouple
Input Impedance 10M AC/ ) (V DC
Display 3999 count LCD
Overrange is displayed “OL
Polarity Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity.
Measurement Rate 3 times per second, nominal
Low Battery is displayed if battery voltage drops below
operating voltage
Batteries Requires (2) AAA batteries
Fuses mA range; 250mA/250V fast blow
10A range, no protection
Operating Temp 32oF to 104o
F (0 oC to 40oC)
Storage Temp -4o
F to 140 o
F (-20 o
C to 60 oC)
Relative Humidity Maximum relative humidity 80% for temperatures
up to 31 C decreasing linearly to 50% relative °
humidity at 40 °C.
Operating Altitude 7000ft (2000 meters) maximum
Weight 5.4 oz. (153g).
Size 138mm x 72mm x 38mm) 5.43” x 2.83x 1.5” (
Safety For indoor use and in accordance with
Overvoltage Category II, Pollution Degree 2.
Category II includes local level, appliance,
portable equipment, etc., with transient
overvoltages less than Overvoltage Category III
Specications
Function
Range
Accuracy
DC Voltage
(V DC)
4 00.0mV
(0.5% reading + 4 digits)
4.000V
(0.8% reading + 4 digits)
40.00V
400.0V
600V
AC Voltage
(V AC)
50-60Hz
4.000V
(0.8% rdg + 4 d)
40.00V
(1.2% rdg + 5 d)
400.0V
600V
DC Current
400.0µA
(1.2% reading + 4 digits)
4000µA
40.00mA
200.0mA
10A
(2.5% reading + 4 digits)
AC Current
(40 to 400Hz)
400.0µA
(1.5% reading + 5 digits)
4000µA
40.00mA
200.0mA
10A
(3% reading + 5 digits)
Resistance
4 00.0
(1.2% reading + 4 digits)
4.000k
40.00k
4 k 00.0
4.000M
20.00M
(3.0% reading + 5 digits)
Capacitance
4.000nF
Not specied
40.00nF
(3.0% reading + digits) 10
400.0nF
4.000µF
40.00µF
Not Specied
100µF
Frequency
10.00Hz
(1.0% reading + 4 digits)
10Hz to 1MHz
Sensitivity: 5.0Vrms
100Hz
1.000kHz
10.00kHz
100.0kHz
1.000MHz
5.000MHz
Not specied
Temp F
Temp C
-40 to
1400 F
-20 to 750 C
-40 to 650°F; (1.0% rdg + digits) 10
651 00 10 to 14 °F; (3% rdg + digits)
-20 to 400 C; (1.0% rdg + digits)   10
400 to 750 C; (3% rdg + digits)   10
(probe accuracy not included)


Produkt Specifikationer

Mærke: Extech
Kategori: Multimeter
Model: MN36

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech MN36 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Extech Manualer

Extech

Extech MA440 Manual

28 August 2024
Extech

Extech EX355 Manual

27 August 2024
Extech

Extech EX623 Manual

27 August 2024
Extech

Extech MA443 Manual

27 August 2024
Extech

Extech MG302 Manual

23 August 2024
Extech

Extech Ex 830 Manual

17 August 2024
Extech

Extech Ex 810 Manual

14 August 2024
Extech

Extech EX 710 Manual

13 August 2024
Extech

Extech MA1500 Manual

12 August 2024
Extech

Extech PRT200 Manual

11 August 2024

Multimeter Manualer

Nyeste Multimeter Manualer