Gerni Classic 100.5 Manual

Gerni Højtryksrenser Classic 100.5

Læs nedenfor 📖 manual på dansk for Gerni Classic 100.5 (7 sider) i kategorien Højtryksrenser. Denne guide var nyttig for 10 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/7
Safety Instructions Original Safety Instructions
Before rst use of the machine, read the instructions
carefully. Save instructions for later use.
Safety instructions marked with this symbol must be
observed to prevent personal injury or serious damage
to property.
The instruction consists of 4 parts. Part 1:3 Safety Instruc-
tions. Part 2:3 Serial speci c User Guide. Part 3:3 Trouble-
shooting, Serial speci c Technical Data and Disposal. Part
1:4 Warranty Conditions.
Warnings This machine has been designed for use with
cleaning agents supplied or recommended by Gerni. The use
of other cleaning agents or chemicals may adversely affect
the safety of the machine. High pressure jets
can be dangerous if subject to misuse. The jet must
not be directed at persons, live electrical equipment
or the machine itself. Do not use the machine
within range of persons unless they wear protective clothes.
Do not direct the jet against yourself or others in order to
clean footwear. Risk of explosion Do not spray amma-
ble liquids. High pressure washers shall not be used by
children or untrained personnel. High pressure hoses,
ttings and couplings are important for the safety of the ma-
chine. Use only hoses, ttings and couplings recommended
by Gerni. To ensure machine safety, use only original
spare parts recommended by Gerni. Water that has own
through back- ow preventers is considered to be non-potable.
Don’t use the machine if a supply cord or important parts
of the machine are damaged, e.g. safety devices, high pres-
sure hoses, trigger gun. Inadequate extension cords can
be dange rous. If an extension cord is used, it shall be suitable
for outdoor use, and the connection has to be kept dry and
off the ground. It is recommended that this is accomplished
by a cord reel which keeps the socket at least 60 mm above
the ground. Switch off and unplug the machine when
leaving it unattended, when nished using it or when convert-
ing it to another function, when doing repair and maintenance.
During use of high pressure washers, aerosols may be
formed. Inhalation of aerosols can be hazardous to health, for
the protection against aerosols a respiratory mask of class
FFP 2 or equivalent may be needed, depending on the clean-
128334140 b (06.2016)
Unit 1/13 Bessemer Street | Blacktown NSW 2148 | Tel.: 1300 556 710
Part 1:3 Safety Instructions, High Pressure Washers, Classic, Classic PG, Super and Super PG
Caution:
Read the instructions
before using the machine
ing environment.
Intended Use and Terms of Liability The Classic, Classic
PG, Super and Super PG series have been developed for
domestic cleaning pur poses only and for use in an upright
position. Any other use is considered as improper use. A
high pressure washer operates with different levels of pressure
and cleaning detergents for various cleaning tasks and results.
Always follow instructions on detergents for use, emergency
and disposal. Do not operate the machine at temperatures
below 0°C. Never start a frozen machine, never use it indoor
and never cover it during use. This is considered improper
and wrongful use. Use of wrongful pressure, detergent and/
or applications may cause damage to machine, surfaces,
material and devices. All of the above is considered improper
and wrongful use. Gerni accepts no liability for any damage
resulting from any improper or wrongful use.
Safety devices and their functioning The machine automa-
tically stops when releasing the trigger. The machine will start
again when reactivating the trigger. The spray handle features
a locking device. When activated, the spray handle cannot be
operated. The machine has an automatic self-resetting thermo
protector. If the machine is overheated, the thermo protector
will cut the power supply. In this case, wait for the machine to
cool down. An integrated hydraulic safety valve protects the
system from excessive pressure.
Precautions The electric supply connection shall be made
by a quali ed electrician and comply with IEC 60364-1. It is
recommended that the electric supply to this machine should
include either a residual current device that will interrupt the
supply if the leakage current to earth exceeds 30 mA for 30
ms or a device that will prove earth circuit. Use motor start/
delayed fuses with characteristic D according to IEC 947-2 or
corresponding standards outside IEC. If the supply cord is
damaged, it must be replaced by an authorized Gerni distrib-
utor or similar quali ed person in order to avoid a hazard.
No actions needed for adjusting machines marked with dual
voltage and frequency. Supervise children not to play with
the machine. The operator and any one in the immediate
vicinity of the site for cleaning should take action to protect
oneself from being struck by debris dislodged during operation.
Always wear safety boots, respiratory mask, ear protection,


Produkt Specifikationer

Mærke: Gerni
Kategori: Højtryksrenser
Model: Classic 100.5

Har du brug for hjælp?

Hvis du har brug for hjælp til Gerni Classic 100.5 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Højtryksrenser Gerni Manualer

Gerni

Gerni Super 130.3 Manual

30 August 2024
Gerni

Gerni Super 140.3 Manual

30 August 2024
Gerni

Gerni 3300 Manual

30 August 2024
Gerni

Gerni Super 160.3 Manual

30 August 2024
Gerni

Gerni Super 150.3 Manual

30 August 2024
Gerni

Gerni 7000 Manual

30 August 2024
Gerni

Gerni 4000 Manual

30 August 2024

Højtryksrenser Manualer

Nyeste Højtryksrenser Manualer