Operating Instructions
PMA 16
Power Measuring Adapter
3-349-030-02
6/12.22
Printed in Germany • Subject to change without notice /
Errors excepted • A PDF version is available on the Internet.
Gossen Metrawatt GmbH
Südwestpark 15
90449 Nürnberg Germany
Phone +49 911 8602-0
Fax +49 911 8602-669
E-Mail info@gossenmetrawatt.com
www.gossenmetrawatt.com
Applications
The PMA 16 power measuring adapter is inserted between
the electrical outlet and the mains plug for safe and conve-
nient measurement of power consumption at single phase
devices under test. The protective conductor of the device
under test remains fully functional.
Safety Precautions
The power measuring adapter is a measuring instrument
accessory in accordance with IEC 61010–1 /
DIN EN 610101 / VDE 0411–1, and may only be used for
its intended purpose.
It may only be used in power systems with nominal voltages of up
to 250 V which are fused at a maximum of 16 A!
Instructions for Use
You will need a power meter which is equipped with con-
nector jacks into which the contact-protected plugs at the
permanently attached measurement cables of the PMA 16
can be plugged. For power measurement we recommend
the METRAHIT ENERGY digital multimeter from Gossen
Metrawatt GmbH.
The following sequence must be observed when connecting
the power measuring adapter to the device under test and
the mains:
Connect the measurement cables from the power mea-
suring adapter to the bonding jack ( : black), the volt-
age input (V: blue) and the current input (A: red) at the
measuring instrument and select the highest possible
power measuring range or Auto Range.
Insert the power measuring adapter into the electrical outlet.
Insert the mains plug from the device under test into the
outlet at the power measuring adapter.
Switch the device under test on and read the measure-
ment value from the display at the measuring instru-
ment. Select a lower measuring range if necessary, in
order to obtain highest possible resolution.
Follow this procedure in reverse in order to disconnect
the power measuring adapter.
COM
V
Temp
mA A
N
PE
L
Load
PMA 16
redblackblue
V A


Produkt Specifikationer

Mærke: Gossen Metrawatt
Kategori: Multimeter
Model: PMA16

Har du brug for hjælp?

Hvis du har brug for hjælp til Gossen Metrawatt PMA16 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Gossen Metrawatt Manualer

Multimeter Manualer

Nyeste Multimeter Manualer

Owon

Owon HDS100 Manual

21 December 2024
Owon

Owon 1000A Manual

18 December 2024
IWH

IWH 73556 Manual

16 December 2024
Vimar

Vimar 20433.N Manual

15 December 2024
Vimar

Vimar 19433.M Manual

15 December 2024
Vimar

Vimar 14433.SL Manual

15 December 2024
Kyoritsu

Kyoritsu KEW-2046R Manual

14 December 2024
Kyoritsu

Kyoritsu KEW 6010B Manual

14 December 2024
Sanwa

Sanwa ACS101 Manual

8 December 2024