Graco SaniSpray HP 20 Manual

Graco Ikke kategoriseret SaniSpray HP 20

Læs nedenfor 📖 manual på dansk for Graco SaniSpray HP 20 (3 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 66 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
ti38477a
Read the sprayer manual 3A7646 (corded) or 3A7649 (cordless)
for complete instructions and warnings. This Quick Guide is not
a substitute for reading and understanding all instructions and
warning labels supplied with the equipment.
CHEMICAL HAZARD: Follow chemical warnings on disinfec-
tant container label and as listed in manual. Do not spray
humans or animals. Wear protective equipment.
FIRE AND EXPLOSION HAZARD: Do not use any alcohol-based
or other flammable liquid in corded sprayer. Follow fire and
explosion warnings as listed in your manual.
SKIN INJECTION HAZARD: High pressure equipment. Keep
clear of spray tip and leaks. Follow the Pressure Relief
Procedure whenever you stop spraying.
FAILURE TO FOLLOW ALL WARNINGS CAN RESULT IN
SERIOUS INJURY, AMPUTATION, OR DEATH.
WARNING
NOTICE
Do not run sprayer without fluid.
Running the sprayer dry will cause damage to the pump.
Disinfectant left in the sprayer will damage the sprayer. To avoid
damage, always completely flush with warm water after every use.
Do not store sprayer with disinfectant in it.
Foam in disinfectant may cause operation issues that could damage
the sprayer. Wait until foam has subsided to fill FlexLiner.
KNOW YOUR CONTROLS
Spray Tip
Spray Tip
Guard
Pump
Filter
Cup lid
Cup Support
Prime Knob
Trigger
Speed
Control
VacuValve
FlexLiner
Pressure Relief Procedure
Follow this procedure whenever instructed
to perform PRESSURE RELIEF PROCEDURE.
Disconnect power (unplug cord
or remove battery).
Turn Prime Knob down to PRIME
position to relieve pressure.
To begin a new job, first
perform the PRESSURE
RELIEF PROCEDURE.
Insert one FlexLiner into the
Cup Support and fill with
properly diluted disinfectant.
• NOTE: Verify there is no
damage, such as a crease, on
the top surface of the FlexLiner.
If damaged DO NOT USE.
Prime the pump with disinfectant
as follows:
A. Verify Prime Knob is pointed down
to PRIME position.
B. Plug the sprayer into a grounded
power source or install a fully
charged battery onto the sprayer.
C. Turn the sprayer upside down.
• Pull the Trigger for 5 seconds.
• NOTE: Disinfectant will not spray
out, but will recirculate through
the pump and back into the cup.
D. Turn the sprayer upright and open
the VacuValve cap.
E. Tilt the sprayer so the VacuValve
is the highest point.
F. Gently squeeze the FlexLiner until
disinfectant enters the VacuValve
reservoir and all air is evacuated
from the cup.
G. While continuing to squeeze
the FlexLiner, close the
VacuValve cap.
• NOTE: If FlexLiner is not
squeezed while VacuValve Cap is
open, air will quickly pull into the
FlexLiner. If any air bubbles are
visible in the cup, repeat steps
E-G.
Firmly tighten Cup Lid onto
Cup Support to ensure an
air tight seal.
Turn Prime Knob forward to
SPRAY position.
Verify Spray Tip is forward in
the SPRAY position.
Pull the Trigger to verify disinfectant
sprays from the sprayer. If sprayer
does not spray within 5 seconds,
STOP and repeat START UP.
YOU ARE NOW READY TO SPRAY!
Install the cup onto the sprayer:
A. Verify Pump Filter is installed
and clean.
B. Align VacuValve (on Cup Lid)
with Prime Knob (on sprayer).
C. Push cup assembly onto the
sprayer. Twist to lock.
Review Important User Information in your sprayer manual to understand
which types of disinfectants are compatible with your sprayer.
This sprayer arrives from the factory with a small amount of test fluid
in the system. It is important that you flush the sprayer with warm
water before using for the first time. See Flushing a New Sprayer in
your sprayer manual.
Refer to disinfectant label for manufacturer’s directions on proper use. If
dilution is required, properly dilute disinfectant in a separate container.
START UP
START UPcontinued
1
1
5
6
7
8
2
3
4
2
AIRLESS HANDHELD


Produkt Specifikationer

Mærke: Graco
Kategori: Ikke kategoriseret
Model: SaniSpray HP 20

Har du brug for hjælp?

Hvis du har brug for hjælp til Graco SaniSpray HP 20 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Graco Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Senal

Senal SCI-3212MP Manual

22 November 2024
Senal

Senal OLM-2S-P Manual

21 November 2024
Senal

Senal ME-220-CL Manual

21 November 2024
Senal

Senal ASM-4 Manual

21 November 2024
Senal

Senal CS-88 Manual

21 November 2024
Senal

Senal CSP-162 Manual

21 November 2024
Senal

Senal MXGN-ICS Manual

21 November 2024
Dubatti

Dubatti Board Two Manual

21 November 2024
Senal

Senal ASM-3 Manual

21 November 2024