GW Instek PEL-3032E Manual

GW Instek Måling PEL-3032E

Læs nedenfor 📖 manual på dansk for GW Instek PEL-3032E (2 sider) i kategorien Måling. Denne guide var nyttig for 3 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
QUICK START GUIDE
GW INSTEK PAR NO. 82EL T -3KE00M 1
A
A
A
AA
This section contains the basic safety symbols that may
appear on the accompanying User Manual CD or on the
instrument. For detailed safety instructions and
precautions, please see the Safety Instructions chapter
in the user manual CD.
These safety symbols may appear in the user manual or
on the instrument.
Warning: Identifies conditions or
practices that could result in injury or
loss of life.
Caution: Identifies conditions or
practices that could result in damage
to the instrument or to other
properties.
DANGER High Voltage
Attention Refer to the Manual
Earth (ground) Terminal
Frame or Chassis Terminal
Do not dispose electronic equipment
as unsorted municipal waste. Please
use a separate collection facility or
contact the supplier from which this
instrument was purchased.
When using the instrument in the United Kingdom,
make sure the power cord meets the following safety
instructions.
As the colours of the wires in main leads may not correspond with
the coloured marking identified in your plug/appliance, proceed as
follows:
The wire which is coloured Green & Yellow must be connected to
the Earth terminal marked with either the letter E, the earth symbol
loured Green/Green & Yellow. or co
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal
marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or
contact the supplier.
This cable/appliance should be protected by a suitably rated and
approved HBC mains fuse: refer to the rating information on the
equipment and/or user instructions for details. As a guide, a cable of
0.75mm2
should be protected by a 3A or 5A fuse. Larger conductors
would normally require 13A types, depending on the connection
method used.
Any exposed wiring from a cable, plug or connection that is engaged
in a live socket is extremely hazardous. If a cable or plug is deemed
hazardous, turn off the mains power and remove the cable, any
fuses and fuse assemblies. All hazardous wiring must be
immediately destroyed and replaced in accordance to the above
standard.
The Getting Started chapter introduces the instrument’s
main features, appearance, and set up procedure.
The PEL-3000E is an economic, standalone, high
performance DC electronic load positioned to test a
wide range of different power sources. The DC
electronic load is fully programmable to simulate
anything from basic static loads to complex dynamic
loads. The PEL-3000E is extremely robust and capable
of molding to any test environment.
PEL 3031E-
1V-150V
6A (Low range)
60A (High range)
300W
PEL 303- 2E
2.5V-500V
1.5A (Low range)
15A (High range)
300W
High slew rates of up to 2.5A/μs
for a fast response speed -(PEL
3031E)
High resolution 16 bit
Mode
CC
I Range
H 60A
V Range
L 15V
Function
Static Configure
0.0000V
0.000A
0.00w
SlewRate 2500
CC B Value 0.000
CC A Value 0.000
LOADUSB
A Value
Fine
mA/us
A
A
1. Main frame status
panel
2. Operation status
panel
3. Soft keys
4. Setting area
5. Measurement area
Use the following when first using the procedures
PEL- E to power up the instrument, restore the 3000
factory default settings and check the firmware
version. Lastly, the Conventions section will introduce
you to the basic operating conventions used
throughout the user manual.







 

 







  
1. J1 Frame control
ports
2. TRIG OUT BNC
3. TRIG IN BNC
4. Exh aust fan
5. Power socket and
switch
6. GPIB (optional)
7. USB device port















 








 



P E L - 3 0 3 1 E


  
1. Air inlet
2. LCD Display
3. Function keys
4. Power key
5. Main/Local key
6. FUNC/File key
7. Help/Utility key
8. Short key
9. Load On/Off
10. Scroll wheel
11. Number pad,
Clear/Lock and Enter
keys
12. USB port, Preset and
Shift keys
13. Sense-, Sense+
terminals
14. Input terminals
User /Programming Manual CD
Quick Start Guide (this document)
Power C ord x1
Region Dependent
Front terminal washers ( M6) x2
61SF-062104N1
Remote sense cables, red x1, black
x1
GTL- 105A
GPIB cable, 2.0m
GTL- 248
USB ca , Type A - ble Type B
GTL- 246
Dust filter
PEL 010-
GPIB option
PEL 004-
This manual contains proprietary information, which is
protected by copyright. All rights are reserved. No part
of this manual may be photocopied, reproduced or
translated to another language without prior written
consent of Good Will Corporation.
The information in this manual was correct at the time
of printing. However, Good Will continues to improve
its products and therefore reserves the right to change
the specifications, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng
Dist. New i ., Taipei C ty 236, Taiwan


Produkt Specifikationer

Mærke: GW Instek
Kategori: Måling
Model: PEL-3032E

Har du brug for hjælp?

Hvis du har brug for hjælp til GW Instek PEL-3032E stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling GW Instek Manualer

GW Instek

GW Instek PEL-3032E Manual

15 November 2024

Måling Manualer

Nyeste Måling Manualer

Testo

Testo easyEmission Manual

15 November 2024
Testo

Testo 755 Manual

15 November 2024
Eastron

Eastron SDM630 Manual

15 November 2024
IFM

IFM SI0551 Manual

15 November 2024
Hikmicro

Hikmicro Eco-V Manual

12 November 2024
Hazet

Hazet 4650-6 Manual

11 November 2024
Clare

Clare SafeCheck 8 Manual

5 November 2024
Dranetz

Dranetz DranXperT Manual

5 November 2024
Stelzner

Stelzner EC 2000 Manual

5 November 2024