Hager EGK101 Manual


Læs nedenfor 📖 manual på dansk for Hager EGK101 (2 sider) i kategorien Digitalt ur. Denne guide var nyttig for 2 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
6LE005554C
Device to be installed only by a qualified
electrician according to the installation
standards applicable in the country.
Not suitable for controlling SELV loads.
zMulti-function Time Switch
1 Channel Bluetooth®
6LE005554C1
Product Presentation
The EGN100 time switch is a clock with weekly and
annual electronic programming that automatically
controls different loads.
Examples of applications: street lighting, neon signs,
shop windows, monuments, facades etc.
The integrated astronomical clock can be set to
switch loads according to sunset and sunrise times.
The EGN100 switch is also compatible with the Hager
Quicklink radio product line.
The connection of an EEN002 / EEN003 twilight
sensor (optional) makes it possible to switch the loads
according to brightness.
Programming is performed with a mobile terminal
via Bluetooth
® technology using the configuration
application (iOS and Android) available as a free
download.
The keys
EGN100
C1/FCT (key and LED) used for:
• output control;
programming the RF
module operating mode,
• Bluetooth® reset.
BLE/CFG (key and LED) used for:
Bluetooth® activation and
deactivation (BLE),
• RF module configuration;
Resetting parameters and RF
modules.
Image 1: Presentation of keys
Main features
Product delivered with updated time and day (Paris).
Programming by application via Bluetooth
®
technology:
- automatic daylight savings time change;
- astronomical mode;
- programming by day or group of days;
- 100 program steps On, Off, pulses .
Permanent overrides On or Off.
Temporary overrides On or Off.
Exceptions (temporary, permanent or delayed) can
be activated remotely using a push button.
Twilight switch function via an EEN002 or EEN003
wired brightness sensor.
Before connecting the cell, or before
carrying out any operations on it, cut the
230 V power supply to the clock.
Connection diagram
L
N
1 5
3 7
2 6
4 8
1 Override input
or exception
2 Brightness sensor
Figure 2: EGN100 connection diagram (1 output)
Technical specifications
Electrical specifications
Supply voltage: 230 V~ +10/-15%
and 240 V~ ± 6%
Network frequency: 50/60 Hz
Consumption: < 170 mW
Output: 1 non-insulated changeover contact with
a voltage measurement of < 1 V for zero-crossing
switching.
Max. breaking capacity: AC1 μ 10A 230 V~
Incandescent light bulbs:
- Power relay with normally open contact/2300 W
- Power relay with normally closed contact/1500 W
Halogen lamps: 230 V~ 2300 W
Fluorescent tubes, compensated // (max. 45 μF):
- Power relay with normally open contact/400 W
- Power relay with normally closed contact/300 W
Fluorescent tubes, uncompensated, series
compensated: 1000 W
Compact fluorescent lamps and LED lamps:
- Power relay with normally open contact/400 W
- Power relay with normally closed contact/300 W
Min. breaking capacity: AC1 100 mA 230 V~
Rated shock voltage: 4 kV
Maximum switching speed at full load: 6 switching
cycles/minute
Functional features
Programming capacity: 100 steps
Min. time between 2 steps: 1 minute
Precision of operation: ± 0.25 s / day
Bluetooth® radio frequency: 2.4 - 2.483 GHz
- Max. transmitting power: 10 mW
- Range: 10 m in free field
- Version: 4.2
Mobile/PC terminal configuration
- iOS version equal to or greater than 8
- Android version equal to or greater than 5.1
- Windows version equal to or greater than 10
- Bluetooth®: version equal to or greater than 4.2
Quicklink radio frequency: 868 - 870 MHz
- Max. transmitting power: 25 mW
- Receiver category 2
- Range: 100 m in free field
Insulation class: 2
Action type: 2B
Software class: Class A
Ball test T°: 75 °C
Upstream protection: 10 A circuit breaker
Stated voltage and current for EMC emissions
testing: 230 V~ / - 0.5 A
Protection class: IP20 (case), IP30 (case under
faceplate)
Impact resistance: IK04
Battery
Power reserve: 10 years
Non-replaceable and non-rechargeable
Case
Dimensions: 18 mm / 1 module
DIN rail mounted independent product according to
EN 60715
Environment
Operating T° -5 °C to +45 °C
Storage T° -25 °C to +70 °C
Relative humidity: 95 % to 20 °C
Pollution category 2
Connection with screw terminals
• Rigid 0.2 to 4 mm2
• Flexible 0.2 to 2.5 mm2
• Screw recess: PH1
Initial set-up
BLUETOOTH
The product must not be in “Quicklink”
configuration mode.
To program and set the clock with a mobile terminal,
the Bluetooth® function must be activated.
Each time the BLE key is pressed (> 2 s) the function
is enabled or disabled.
BLE LED status / Operation
off Bluetooth® disabled
Blue
Bluetooth® enabled
Blue
Bluetooth® assembled and
connected
Figure 3: LED operation and status
CONFIGURATION APPLICATION
To set the clock, use the application and perform the
installation as described below.
1. Directly access the application’s download link by
scanning the printed on the instructions QR code
with a mobile terminal.
2. Download and install the configuration application.
3. Check that Bluetooth
® is enabled (see Initial set-up
/ BLUETOOTH).
4. Pair your mobile terminal and your clock via the
Bluetooth® application.
5.
Program your product via the application. To do this,
follow the application instructions to configure the
clock.
Settings via the configuration application:
Settings for the use of your clock are available via the
application as settings of:
date and time;
astronomical clock;
wired input;
daylight savings time change;
twilight sensor.
Hager Mood
Additional information is available by
scanning the displayed QR code with
your mobile terminal.
EGN100


Produkt Specifikationer

Mærke: Hager
Kategori: Digitalt ur
Model: EGK101

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager EGK101 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Digitalt ur Hager Manualer

Hager

Hager FN376E Manual

9 December 2024
Hager

Hager EGK101 Manual

8 December 2024

Digitalt ur Manualer

Nyeste Digitalt ur Manualer