Hager Vision VKG22G Manual

Hager niet gecategoriseerd Vision VKG22G

Læs nedenfor 📖 manual på dansk for Hager Vision VKG22G (2 sider) i kategorien niet gecategoriseerd. Denne guide var nyttig for 2 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
WARNING
To prevent overheating or fire, use this control as an operating or regulating
thermostat. ALWAYS USE A BACKUP CONTROL OR ALARM if a control
failure could cause the controlled appliance to overheat or could cause a fire
Where thermostat is capable of cycling directly between heating and cooling
loads, failure to provide a load transfer switch will result in thermostat failure.
Do not install, use or operate if product appears damaged, the enclosure is
cracked or broken or if the sensor has been bent, crimped or is dirty.
APPROPRIATE APPLICATION
This thermostat has been tested by CSA and Underwriters Laboratories Inc.
(UL), meets the requirements for NEMA 4X equipment and is suitable for use
under the National Electrical Code (NEC), Article 547-7, when used with
appropriate watertight connectors (not included).
INSTALLATION
Installation must be made by a trained, qualified service person in accordance
with the National Electrical Code (NEC) and all applicable local codes and
ordinances. Installation should meet all applicable national, state and local
codes. Refer to the appropriate wiring diagram included. Locate the thermostat
( local sensing models ) or sensing bulb ( remote sensing models ) for optimum
temperature sensing of the controlled space. Thermostat operation will be
affected by unusual heat or cold, such as direct sunlight, near windows or doors
or on outside walls.
All fittings and materials used for the installation should be approved, suitable
and installed properly for the intended application. For water tightness, the cord
seal or conduit hub should be UL listed and marked 4X. The conduit hub is to be
tightened onto the conduit before installing in the enclosure.
Where applicable, remove knockout(s) by impacting near the inside edge of the
knockout to be removed. IMPORTANT: Do not impact, dent or use the
sensor for support. This will cause calibration and/or thermostat failure.
To avoid electrical shock or damage to equipment, disconnect all power
before installing or servicing.
To avoid potential fire and/or explosion, do not use in potentially flammable or
explosive atmospheres.
WARNING
WARNING
READ INSTRUCTION CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE OR SERVICE THIS THERMOSTAT. Failure to
observe safety information and comply with instructions could result in
PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE.
Retain these instructions for future reference. This product, when installed,
will be part of an engineered system whose specifications and performance
characteristics are not designed or controlled by PECO. You must review
your application and national and local codes to assure that your
installation will be functional and safe.
Even though this thermostat is sealed, water or dust could enter through
improperly sealed wiring. A drip loop should be provided to prevent water and
other liquids from entering the thermostat housing. The cord or conduit
connections to the enclosure must be water and dust tight. The cover must be
tightened securely to compress the gasket and provide a watertight seal. Use
only screws provided. Do not over-tighten.
Maximum sensing element withstand temperature is 35°F (20°C) above the
highest temperature setting. Maximum temperature for the plastic enclosure is
140°F 60°C.
OPERATION AND CHECK-OUT
Allow one hour or necessary amount of time for the thermostat and system to
stabilize for normal operation. This thermostat is factory calibrated and
requires no correction on site.
TO CHECK OPERATION OF HEATING SYSTEMS:
1. Disconnect power.
2. Place the heat/cool selector switch, if applicable, in the heat position.
3. Adjust the thermostat set point to at least 10°F (5°C) below the
temperature of the controlled space.
4. Restore power.
5. Slowly adjust the thermostat knob to raise the set point. When the set
point reaches the approximate temperature of the controlled space, the
heating equipment should start.
TO CHECK OPERATION OF COOLING SYSTEMS:
1. Disconnect power.
2. Place the heat/cool selector switch, if applicable, in the cool position.
3. Adjust the thermostat set point to at least 10°F (5°C) above the
temperature of the controlled space.
4. Restore power.
5. Slowly adjust the thermostat knob to lower the set point. When the set
point reaches the approximate temperature of the controlled space, the
cooling equipment should start.
For use in wet or humid environments or where water tightness is required,
failure to use suitable watertight connections and suitable drip loop could
allow water to enter the enclosure resulting in thermostat failure.
Use copper wire only. Insulate or wire-nut all unused leads.
Use the grounding provisions provided for connection to the line ground
and equipment ground wire.
LIMITED WARRANTY
1. WARRANTY COVERAGE. PECO warrants to the original user of its products that the
products will, at the date of initial purchase, meet the applicable specification for such
products and will be free from any defects in materials or manufacture under normal use
for 18 months after date of manufacture.
2. DISCLAIMER OF WARRANTY OF PRODUCT SUITABILITY. PECO makes no
warranty to the purchaser or any third party that its products are suitable for a particular
application or design. Many states and localities have differing codes or regulations
governing the installation and/or use of PECO' products. PECO cannot guarantee
compliance with such regulations; purchaser is solely responsible for safe and correct
installation and use of the product and for compliance with applicable codes and
regulations.
3. EXCLUSION OF IMPLIED WARRANTIES. This warranty is the only warranty
applicable to this product and excludes all other warranties, including any WARRANTY OF
MERCHANTABILITY, any warranty of fitness for a particular purpose, and any implied
warranties otherwise arising from course of dealing or usage of trade, except where the
product purchased is subject to consumer product warranty laws, in which case ANY
APPLICABLE IMPLIED WARRANTIES ARE LIMITED TO 18 MONTHS, or such shorter
period as permitted or required under applicable law.
Some States do not allow limitations on how long an implied warranty lasts, so the above
limitations may not apply to you.
4. REMEDIES FOR NONCONFORMITY. If the product purchased does not conform to the
applicable warranty, PECO will provide, at its option and in accordance with the
procedures in the following section, one of the following remedies: (1) repair of the
nonconforming product, (2) replacement with a conforming product, (3) refund of the
original purchase price. THESE REMEDIES SHALL BE THE EXCLUSIVE AND SOLE
REMEDY for any breach of warranty.
5. TO OBTAIN WARRANTY SERVICE. For any product believed to be defective within the
limited warranty period, first write or call dealer from whom product was purchased.
Dealer will give additional directions. If unable to resolve satisfactorily, write to PECO at
the address below, giving dealer's name, address, date and number of dealer's invoice,
and describe the nature of the defect.
6. LIMITATION OF LIABILITY. PECO WILL NOT BE LIABLE FOR ANY INCIDENTAL,
SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES resulting from any defect in the
product purchased. Some States do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which
vary from State to State.
Manufactured by PECO, Inc.
4709 SE 18th Avenue - Portland, OR 97202 - USA
P.O. Box 82189 - Portland, OR 97282 - USA
NEMA 4X RAINTIGHT THERMOSTAT
INSTALLATION AND OPERATING INSTRUCTIONS
INSTRUCCIONES DE INSTALACION Y OPERACION
DEL THERMOSTATO A PRUEBA DE LLUVIA NEMA 4X
THERMOSTAT NEMA 4X ÉTANCHE AUX INTEMPÉRIES
INSTRUCTION D'INSTALLATION ET D'UTILISATION
CAUTION
P/N 68087 / 3220-1188 / REV 0 / PAGE 1


Produkt Specifikationer

Mærke: Hager
Kategori: niet gecategoriseerd
Model: Vision VKG22G

Har du brug for hjælp?

Hvis du har brug for hjælp til Hager Vision VKG22G stil et spørgsmål nedenfor, og andre brugere vil svare dig




niet gecategoriseerd Hager Manualer

Hager

Hager JF801SPD Manual

9 September 2024
Hager

Hager K7B3M1W Manual

7 September 2024
Hager

Hager JK104BDFG Manual

7 September 2024
Hager

Hager K7T3M075W Manual

7 September 2024
Hager

Hager JF4508TM Manual

28 August 2024
Hager

Hager JK116E Manual

28 August 2024
Hager

Hager JK102LE Manual

28 August 2024
Hager

Hager JK216E Manual

28 August 2024
Hager

Hager JF14006SM Manual

28 August 2024
Hager

Hager JK232E Manual

28 August 2024

niet gecategoriseerd Manualer

Nyeste niet gecategoriseerd Manualer