Hikvision DS-PDPG12P-EG2 Manual


Læs nedenfor 📖 manual på dansk for Hikvision DS-PDPG12P-EG2 (6 sider) i kategorien Bevægelsesdetektor. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/6
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
E N G L I S H
1
2
34
Specication
Appearance
1. Lens 2. Pet Mask 3. LED Light Pipe
a. Tamper Resistance: 1K, 2K2, 4K7, 5K6
b. PIR Alarm Resistance: 1K, 2K2, 4K7, 5K6, 6K8
c. BG Alarm Resistance: 1K, 2K2, 4K7, 5K6, 6K8
Note: The resistor must be connected in series with one end of the
detector.
a.Normally Closed
b. Single End of Line Wiring
c. Double End of Line Wiring:
Powering On
The 12 m Lens
1
Installation
Wired PIR-Glass Break Detector
DS-PDPG12P-EG2
User Manual
1 2 3 4 7
8
4. Lens Holder
5. Pick Up PCBA 6. Slider 7. Main PCBA
AUTO
PET
LED ON
LED OFF
1
7
9
10
11
1K, 2K2,
4K7, 5K6
4
1K, 2K2,
4K7, 5K6, 6K8
8
1K, 2K2,
4K7, 5K6, 6K8
5
6
3
LINK PIR&TAMPER
LINK BG&TAMPER
UN-LINK
2
0 to 8 m
7The Main Printed Circuit Board Assembly (PCBA)
1. PIR Sensor 2. BG Potentionmeter 3. PIR Sensitivity Settings
5. PIR Alarm Resistor Pin
6. Microphone
9. Tamper Spring
Alarm: (Blue)
4. Tamper Resistor Pin
45.5 mm
103.8 mm
85.9°
Detection Range
52 zones
4 planes
2.4m
8m
10m
1m
2m
6m
4m
12m
8m 10m1m 2m 4m 6m 12m
This PIR detector is approved at 1.8 m ~ 2.4 m mounted.
Recommended mounting height: 2.2 m.
8m 10m1m 2m 4m 6m 12m
1 2
=
=
a1
b
4K7
2K2
1K
5K6
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
2.2K
RT
4K7
2K2
1K
5K6
6K8
PIR
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
2.2K
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
2.2K
4K7
2K2
1K
5K6
6K8
BG
=
=
a2
4K7
2K2
1K
5K6
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
RT
c
2.2K
LINK PIR&TAMPER
LINK BG&TAMPER
NOT READY READY
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
RT BGPIR
LINK HEADER
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
4K7
2K2
1K
5K6
6K8
4K7
2K2
1K
5K6
4K7
2K2
1K
5K6
6K8
ZONE2COM ZONE1COM
+ -
ZONE3COM
2.2k
2.2k
2.2k
RT
PIR BG
A
Screw Model: PA_3.5 ×25 (4 screws)
A. Wall Mounting B. Bracket Mounting (optional)
4a. Ceiling Bracket Mounting 4b. Wall Bracket Mounting
5. Knock out the hole,and adjust slider direction.
Resistor Wiring
Connection Type
Method 1: Use the jumper to select EOL (End of Line) resistance on
TAMPER/ALARM pins.
Method 2: Add the resistor to TAMPER/ALARM wiring ports.
Note: If EOL wiring is not used, leave the jumpers OFF. Do not force the
jumper if it is not matched the pin. Method 1 & 2 should not be used on the
ALARM/TAMPER at the same time.
2
3
5
6
76ab1 b2
c1 c2
7
UD23756B-E
65.7 mm
5 6
8. Screw
7. Terminal
B
3 4
34a 4b
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
4K7
2K2
1K
5K6
6K8
4K7
2K2
1K
5K6
4K7
2K2
1K
5K6
6K8
ZONE2COM ZONE1COM
+ -
ZONE3COM
RT
PIR BG
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
4K7
2K2
1K
5K6
6K8
4K7
2K2
1K
5K6
4K7
2K2
1K
5K6
6K8
ZONE2COM ZONE1COM
+ -
ZONE3COM
RT
PIR BG
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
4K7
2K2
1K
5K6
6K8
4K7
2K2
1K
5K6
4K7
2K2
1K
5K6
6K8
ZONE2COM ZONE1COM
+ -
ZONE3COM
RT
PIR BG
2.2k
8. BG Alarm Resistor Pin
10. LED ON/OFF 11. Link Settings
5
Relay Status
4
Normal PIR Intrusion/Fault BG Intrusion/Fault Tamper
PIR Alarm Relay Close Open Close Close
BG Alarm Relay Close Close Open Close
Tamper Relay Close Close Close Open
5
PIR Triggered: (Green) BG Triggered: (Red)
Fault: PIR: (Green) BG: (Red) BG&PIR: (Orange)
2.2k 2.2k
BG ALARMPIR ALARM +-
EOLEOL
TAMPER
EOL
4K7
2K2
1K
5K6
6K8
4K7
2K2
1K
5K6
4K7
2K2
1K
5K6
6K8
ZONE2COM ZONE1COM
+ -
ZONE3COM
RT
PIR BG
2.2k
LINK PIR&TAMPER
LINK PIR&TAMPER
LINK BG&TAMPER
LINK BG&TAMPER
EN 50131-2-2:2017
EN 50131-2-7-1+A1+A2
Security Grade 2, Environment Class II
Certified by V Rheinland
• Please use the power adapter complianting with LPS. The recommended power adapter is made by
Shenzhen Honor Electronic Co., Ltd.
• Please use the power supplies comply with the requirements of EN 50131-6 at the appropriate grade
and environmental class.
• Not to obscure partially or completely the detector's field of view with large objects such as furniture,
curtains, blinds, etc.
• Make sure that any curtains, plants, furniture, or other objects do not overcover the microphone
opening.
• If there are curtains on the window, place the detector between them and the window, for instance, at
the window side jamb. Otherwise, curtains can mute the glass break sound, and the detector will not be
triggered.
• Before installing the detector, make sure that you have select the optimal location that follows the
guidelines of this manual
– Avoid mounting the detector on the same wall as the protected glass.
– Avoid mounting the detector in rooms with noisy equipment (air compressors, power tools, bells, etc.)
– Avoid mounting the detector in humid rooms (bathroom, etc.)
– Avoid mounting the detector on the wall with strong vibration.
Detection Range 12 m, 85.9°
Detectable Speed 0.3 to 2 m/s
Pet Immunity 30 Kg
PIR Sensitivity Auto,Pet
White Light Filter 6500lux
Glass Break Range 8m
Glass Type Float, Coated, Tempered, Laminated,
Sealed Insulating, Wired
Digital Temperature
Compensation Support
Creep Zone Protection Support
Digital Processing Support
Sealed Optics Support
Tamper Protection Front
LED Indicator Green(PIR),Red(BG),Blue(alarm)
Power Supply 9 to 16 VDC (standard: 12 VDC)
Power Consumption 36 mA
Operation Temperature -10 °C to 55 °C (14 °F to 131 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F)
Operation Humidity 10% to 90%
Dimension(W×H×D) 65.5 mm × 103 mm × 48.5 mm
Weight 98.5 g
Mounting Height 1.8 to 2.4 m
Mounting Method Wall
Application Scenario Indoor
Bracket Optional Wall & Ceiling Accessory
Glass thickness 3 mm to 6.4 mm
Glass Size 0.3 m × 0.3 m to 3 m × 3 m


Produkt Specifikationer

Mærke: Hikvision
Kategori: Bevægelsesdetektor
Model: DS-PDPG12P-EG2

Har du brug for hjælp?

Hvis du har brug for hjælp til Hikvision DS-PDPG12P-EG2 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Bevægelsesdetektor Hikvision Manualer

Bevægelsesdetektor Manualer

Nyeste Bevægelsesdetektor Manualer

Optex

Optex FLX-S Manual

17 December 2024
EQ-3

EQ-3 HM-Sec-MDIR-2 Manual

16 December 2024
Optex

Optex SIP-100 Manual

16 December 2024
Optex

Optex SL-350QDM Manual

16 December 2024
Optex

Optex SIP-3020WF Manual

16 December 2024
Optex

Optex FLX-P Manual

16 December 2024
Optex

Optex FLX-A Manual

16 December 2024
Vimar

Vimar 20485.B Manual

15 December 2024
Vimar

Vimar 20485.N Manual

15 December 2024
Vimar

Vimar 14485.SL Manual

15 December 2024